What is the correct formula for calculating thoracic compliance?
What is the correct formula for calculating thoracic compliance?
- Peak airway pressure / Peak flow
- Tidal Volume / Plateau pressure
- None
- Tidal volume / (Plateau pressure - PEEP) (correct)
Which mode of triggering creates more work of breathing on a ventilator?
Which mode of triggering creates more work of breathing on a ventilator?
- Time
- Pressure triggering (correct)
- Flow triggering
- Volume
Which is a significant advantage of placing a blood gas analyzer in standby mode?
Which is a significant advantage of placing a blood gas analyzer in standby mode?
- It saves current
- Both (correct)
- None
- It saves chemicals
What is the appropriate frequency for conducting EST on a mechanical ventilator?
What is the appropriate frequency for conducting EST on a mechanical ventilator?
What role do the keyboard and mouse pointer play in computer operations?
What role do the keyboard and mouse pointer play in computer operations?
Which type of electrode is the reference electrode in a blood gas analyzer?
Which type of electrode is the reference electrode in a blood gas analyzer?
In which setting is an oxygen concentrator most appropriately used?
In which setting is an oxygen concentrator most appropriately used?
Which method of disinfection is not included in the options provided?
Which method of disinfection is not included in the options provided?
Study Notes
Thoracic Compliance
- Calculated as Tidal Volume / (Plateu pressure - PEEP)
Work of Breathing on Ventilator
- More with Pressure triggering
Blood Gas Analyzer Standby Mode
- Saves both current and chemicals
Mechanical Ventilator EST
- Performed each time before applying on a new patient
- Also done during servicing
Computer Keyboard and Mouse
- Act as input devices
Window Operating System
- None of the listed options are correct (memory driven, AC driven, voltage driven)
Reference Electrode in Blood Gas Analyzer
- A cathode
Oxygen Concentrator
- Better applied at home
ICU Room Disinfection
- May be done using Ozone gas, UV Germicidal light, or a combination of both
Stochastic Signal
- Example: ECG in multi-channel monitor
NRBM Valve
- One way
Transport Ventilator FIO2
- Achieved by regulation of O2 flow at the source and by using a blender
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge on the crucial aspects of respiratory equipment, including ventilators, blood gas analyzers, and oxygen concentrators. This quiz covers fundamental principles and operational procedures necessary in a clinical setting. Perfect for nursing and medical professionals aiming to enhance their expertise.