13 Questions
Why is the nasal cannula ineffective when the patient's nose is blocked by blood or mucus?
It reduces the concentration of inspired oxygen
What is the maximum oxygen flow rate for a nasal cannula?
4 L per min
Why should the oxygen delivery through any face mask always exceed the minimum flow rate of 6L per min?
To prevent CO2 accumulation in the mask
What oxygen concentration range can be delivered through a simple face mask?
35% to 60%
What is the main benefit of the Venturi mask?
Precise regulation of Fi O2
In which condition is the Venturi mask typically used?
Lung and chest injuries preventing sufficient oxygen intake
What is the purpose of the color-coded adapters attached to the Venturi mask?
To control the oxygen flow rate
Why are Venturi masks advised for patients with COPD?
To ensure precise regulation of Fi O2
What could happen if a partial rebreather mask is used with a flow rate above 10L per min?
Oxygen concentration will not be enhanced
What happens to the portion of the patient's exhaled gas that enters the reservoir bag of a partial rebreather mask?
It is reused
In which type of patients should the non-rebreather mask most often be used?
Patients needing high-concentration oxygen delivery
What is the purpose of the flutter valve assembly in the non-rebreather mask?
To prevent exhaled air from returning to the reservoir bag
What should paramedics do to ensure the proper functioning of the non-rebreather mask?
Maintain at least two-thirds fullness of the reservoir bag
Study Notes
Nasal Cannula
- Ineffective when the patient's nose is blocked by blood or mucus due to obstructed oxygen flow
- Maximum oxygen flow rate is 6L per min
Face Masks
- Oxygen delivery should always exceed 6L per min to prevent rebreathing of carbon dioxide
- Simple face mask can deliver an oxygen concentration range of 40-60%
Venturi Mask
- Main benefit is precise oxygen concentration delivery
- Typically used in conditions requiring precise oxygen control, such as COPD
- Color-coded adapters attached to the Venturi mask indicate the corresponding oxygen concentration
- Advised for patients with COPD as it provides a precise oxygen concentration, which is crucial for these patients
Partial Rebreather Mask
- Using a flow rate above 10L per min can cause the mask to become a non-rebreather mask
- The portion of the patient's exhaled gas that enters the reservoir bag is rebreathed, allowing for some oxygen conservation
Non-Rebreather Mask
- Most often used in patients who require high oxygen concentrations and are at risk of respiratory failure
- The flutter valve assembly in the non-rebreather mask prevents exhaled gas from entering the reservoir bag
- To ensure proper functioning, paramedics should check the valve assembly and replace the oxygen reservoir bag regularly
Test your knowledge on oxygen masks and flow rates with this quiz. Learn about the importance of proper mask fitting and the impact of flow rates on oxygen concentration. Explore the features and functions of the SUHAIB M AL-SARHAN PARITAL REBREATHER MASK.