Questions and Answers

Which protocol is widely used in modern SCADA systems?

  • IEC 104 (correct)
  • IEC 101
  • Modbus TCP
  • TCP/IP
  • What is the reserved TCP port for IEC 104 protocol?

  • 101
  • 104
  • 60870
  • 2404 (correct)
  • What does a Modbus client use to communicate a specific task to a Modbus server?

  • Function codes (correct)
  • Exception codes
  • Memory type
  • TCP/IP
  • Which of the following is an example of a common exception code used by a Modbus server?

    <p>02; Bad memory address</p> Signup and view all the answers

    What does IEC 104 protocol extend from?

    <p>IEC 101 protocol</p> Signup and view all the answers

    In a Modbus transaction, what can be included?

    <p>Single item or multiple items</p> Signup and view all the answers

    What memory type can a Modbus client write to or read from?

    <p>Specific memory type</p> Signup and view all the answers

    What is the purpose of function codes in Modbus communication?

    <p>Communicate a specific task to the Modbus server</p> Signup and view all the answers

    What did the server indicate with the exception code 01-1 in Modbus communication?

    <p>Don't understand this function code</p> Signup and view all the answers

    What is the primary task of the Modbus primary in communication with the Modbus secondary?

    <p>Communicate a specific task</p> Signup and view all the answers

    What is the port number used by IEC 104 protocol for TCP communication?

    <p>2404</p> Signup and view all the answers

    What is the main purpose of IEC 104 protocol?

    <p>Transport IEC 101 telecontrol messages over TCP</p> Signup and view all the answers

    Which region primarily uses DNP3 protocol?

    <p>USA</p> Signup and view all the answers

    What is the maximum number of objects that can be transmitted in each ASDU of IEC 104 protocol?

    <p>127</p> Signup and view all the answers

    What does the Application Protocol Control Information (APCI) of IEC 104 protocol consist of?

    <p>Header with protocol control information</p> Signup and view all the answers

    Which protocol is the IEC 104 protocol built on top of?

    <p>IEC 101</p> Signup and view all the answers

    What is the biggest advantage of IEC 104 protocol?

    <p>Enables communication through a standard network for simultaneous data transmission</p> Signup and view all the answers

    What is the maximum number of APDUs that can be carried in each TCP payload of IEC 104 protocol?

    <p>Depends on the TCP maximum segment size (MSS)</p> Signup and view all the answers

    What is the fixed length of the data unit identifier in each ASDU of IEC 104 protocol?

    <p>Six bytes</p> Signup and view all the answers

    What type of network protocol is IEC 104 protocol?

    <p>IP-compliant network protocol</p> Signup and view all the answers