Podcast
Questions and Answers
The Capillary number is one of the common parameters affecting droplet formation at T-Junctions.
The Capillary number is one of the common parameters affecting droplet formation at T-Junctions.
True
The flow rate ratio at a T-Junction is calculated as the ratio of QD to QF.
The flow rate ratio at a T-Junction is calculated as the ratio of QD to QF.
False
The viscosity ratio is represented by the symbols μD and μF.
The viscosity ratio is represented by the symbols μD and μF.
False
The aspect ratio in droplet formation at T-Junctions refers to the ratio of channel height to width.
The aspect ratio in droplet formation at T-Junctions refers to the ratio of channel height to width.
Signup and view all the answers
In Plug Generation at T-Junctions, different angles have no effect on the process.
In Plug Generation at T-Junctions, different angles have no effect on the process.
Signup and view all the answers
Squeezing primarily occurs at low flow rates in the context of droplet formation.
Squeezing primarily occurs at low flow rates in the context of droplet formation.
Signup and view all the answers
In the formation of droplets at a T-junction, the cutting rate is unaffected by flow rates and channel dimensions.
In the formation of droplets at a T-junction, the cutting rate is unaffected by flow rates and channel dimensions.
Signup and view all the answers
In the creation of double (multi-) emulsions, the hydrophobic channel wall is preferred for O/W emulsions.
In the creation of double (multi-) emulsions, the hydrophobic channel wall is preferred for O/W emulsions.
Signup and view all the answers
For flow focusing, in a hydrodynamic focusing arrangement, the dispersed phase is expanded at a constriction.
For flow focusing, in a hydrodynamic focusing arrangement, the dispersed phase is expanded at a constriction.
Signup and view all the answers
In the process of droplet formation by flow focusing, water is not used as part of the arrangement.
In the process of droplet formation by flow focusing, water is not used as part of the arrangement.
Signup and view all the answers
Passive structures play a significant role in the design and functioning of microfluidic systems like Bio-MEMS.
Passive structures play a significant role in the design and functioning of microfluidic systems like Bio-MEMS.
Signup and view all the answers
Plugs are commonly used in T-Junction flow configurations to control the droplet formation process.
Plugs are commonly used in T-Junction flow configurations to control the droplet formation process.
Signup and view all the answers
Passive structures are not involved in the formation of droplets at T-junctions.
Passive structures are not involved in the formation of droplets at T-junctions.
Signup and view all the answers
Coaxial injection is a common method used for droplet formation at T-junctions.
Coaxial injection is a common method used for droplet formation at T-junctions.
Signup and view all the answers
Droplet formation at T-junctions only occurs for small flow rates of the continuous phase.
Droplet formation at T-junctions only occurs for small flow rates of the continuous phase.
Signup and view all the answers
The value of α in the equation Qwater = 1 + α * w * Qoil depends on the viscosity of the fluids.
The value of α in the equation Qwater = 1 + α * w * Qoil depends on the viscosity of the fluids.
Signup and view all the answers
Plugs are commonly formed at T-junctions due to high shear stress.
Plugs are commonly formed at T-junctions due to high shear stress.
Signup and view all the answers
The formation of droplets at T-junctions is not affected by interfacial tension.
The formation of droplets at T-junctions is not affected by interfacial tension.
Signup and view all the answers