Questions and Answers
What is the main focus of medical instrumentation?
What is the main focus of medical instrumentation?
- Healthcare applications. (correct)
- Industrial automation
- Aerospace engineering.
- Environmental monitoring.
Which of the following is an example of a diagnostic tool in medical instrumentation?
Which of the following is an example of a diagnostic tool in medical instrumentation?
- Infusion pumps.
- MRI scanners. (correct)
- Dialysis machines.
- Pacemakers.
Which of the following is classified as a therapeutic device?
Which of the following is classified as a therapeutic device?
- Surgical devices. (correct)
- Automated analyzers.
- Blood pressure cuffs.
- Pulse oximeters.
What does a sensor/transducer do in a medical instrumentation system?
What does a sensor/transducer do in a medical instrumentation system?
Which unit includes amplification and filtering to improve signal quality?
Which unit includes amplification and filtering to improve signal quality?
What is the function of the processing unit in a medical instrumentation system?
What is the function of the processing unit in a medical instrumentation system?
What does the 'direct mode' of biomedical instrumentation involve?
What does the 'direct mode' of biomedical instrumentation involve?
Which mode measures signals at specific intervals?
Which mode measures signals at specific intervals?
What is a key characteristic of instruments operating in 'continuous mode'?
What is a key characteristic of instruments operating in 'continuous mode'?
An insulin pump is an example of which operational mode?
An insulin pump is an example of which operational mode?
Which of the following is a type of constraint in medical measurements?
Which of the following is a type of constraint in medical measurements?
What is 'biological variability' in the context of medical measurement constraints?
What is 'biological variability' in the context of medical measurement constraints?
What is the impact of 'motion artifacts' on medical measurements?
What is the impact of 'motion artifacts' on medical measurements?
Which medical instrument is classified as a diagnostic instrument?
Which medical instrument is classified as a diagnostic instrument?
Which describes an assistive medical instrument?
Which describes an assistive medical instrument?
Which of the following is an example of a monitoring instrument?
Which of the following is an example of a monitoring instrument?
What is the purpose of calibration?
What is the purpose of calibration?
Why filtering is used?
Why filtering is used?
What issue does drift compensation address?
What issue does drift compensation address?
Compensating for changes in skin impedance due to temperature changes when using ECG electrodes exemplifies which compensation technique?
Compensating for changes in skin impedance due to temperature changes when using ECG electrodes exemplifies which compensation technique?
What is the purpose of temperature compensation in medical instruments?
What is the purpose of temperature compensation in medical instruments?
What is the primary cause of drift in medical sensors?
What is the primary cause of drift in medical sensors?
Which describes the purpose of periodic calibrations under drift compensation?
Which describes the purpose of periodic calibrations under drift compensation?
What is the purpose of high-pass filters in drift compensation?
What is the purpose of high-pass filters in drift compensation?
In medical research, what is the purpose of a 'double-blind study'?
In medical research, what is the purpose of a 'double-blind study'?
Which of the following is an example of descriptive statistics?
Which of the following is an example of descriptive statistics?
What does 'Standard Deviation' measure in a dataset?
What does 'Standard Deviation' measure in a dataset?
A dataset can be which of the following?
A dataset can be which of the following?
Select the option that best applies to Standard Deviation
Select the option that best applies to Standard Deviation
What does a correlation coefficient of +1 indicate?
What does a correlation coefficient of +1 indicate?
If tall people tend to weigh more, it can be represented by which of these Correlation Coefficients?
If tall people tend to weigh more, it can be represented by which of these Correlation Coefficients?
Static characteristics are concerned with what kind of relationship?
Static characteristics are concerned with what kind of relationship?
Which is the closest value to the definition of accuracy?
Which is the closest value to the definition of accuracy?
What does high 'precision' indicate?
What does high 'precision' indicate?
What is the measure of how closely a system approximates a straight line?
What is the measure of how closely a system approximates a straight line?
What does the 'sensitivity' of a system refer to?
What does the 'sensitivity' of a system refer to?
What does a system's 'resolution' describe?
What does a system's 'resolution' describe?
What does the term 'Drift' refers to?
What does the term 'Drift' refers to?
What is hysteresis?
What is hysteresis?
What are dynamic characteristics?
What are dynamic characteristics?
Flashcards
Instrumentation
Instrumentation
The science and technology of designing, developing, and utilizing devices or systems that measure, monitor, automate, and control physical processes.
Medical Instrumentation
Medical Instrumentation
A specialized branch of instrumentation focused on healthcare; devices and systems used to diagnose, monitor, treat, or research medical conditions.
Sensor/Transducer
Sensor/Transducer
Converts a physiological signal (e.g., biopotential, pressure, temperature) into an electrical signal.
Signal Conditioning Unit
Signal Conditioning Unit
Signup and view all the flashcards
Processing Unit
Processing Unit
Signup and view all the flashcards
Output Display & Recording Unit
Output Display & Recording Unit
Signup and view all the flashcards
Direct Mode
Direct Mode
Signup and view all the flashcards
Indirect Mode
Indirect Mode
Signup and view all the flashcards
Sampling Mode
Sampling Mode
Signup and view all the flashcards
Continuous Mode
Continuous Mode
Signup and view all the flashcards
Automatic Mode
Automatic Mode
Signup and view all the flashcards
Manual Mode
Manual Mode
Signup and view all the flashcards
Real-time Mode
Real-time Mode
Signup and view all the flashcards
Delayed Time Mode
Delayed Time Mode
Signup and view all the flashcards
Biological Variability
Biological Variability
Signup and view all the flashcards
Environmental Factors
Environmental Factors
Signup and view all the flashcards
Motion Artifacts
Motion Artifacts
Signup and view all the flashcards
Time Lag
Time Lag
Signup and view all the flashcards
Signal/frequency ranges
Signal/frequency ranges
Signup and view all the flashcards
Safety
Safety
Signup and view all the flashcards
Calibration
Calibration
Signup and view all the flashcards
Filtering
Filtering
Signup and view all the flashcards
Temperature Compensation
Temperature Compensation
Signup and view all the flashcards
Motion Artifact Reduction
Motion Artifact Reduction
Signup and view all the flashcards
Drift Compensation
Drift Compensation
Signup and view all the flashcards
Drift compensation
Drift compensation
Signup and view all the flashcards
Biostatistics
Biostatistics
Signup and view all the flashcards
Mean, Median, Mode
Mean, Median, Mode
Signup and view all the flashcards
Standard Deviation & Variance
Standard Deviation & Variance
Signup and view all the flashcards
Regression Analysis
Regression Analysis
Signup and view all the flashcards
Signal-to-Noise Ratio (SNR)
Signal-to-Noise Ratio (SNR)
Signup and view all the flashcards
Sensitivity & Specificity
Sensitivity & Specificity
Signup and view all the flashcards
Receiver Operating Characteristic (ROC) Curves
Receiver Operating Characteristic (ROC) Curves
Signup and view all the flashcards
Static Characteristics
Static Characteristics
Signup and view all the flashcards
Accuracy
Accuracy
Signup and view all the flashcards
Precision
Precision
Signup and view all the flashcards
Linearity
Linearity
Signup and view all the flashcards
Sensitivity
Sensitivity
Signup and view all the flashcards
Resolution
Resolution
Signup and view all the flashcards
Range (or Span)
Range (or Span)
Signup and view all the flashcards
Study Notes
Course Overview
- The course primarily uses the textbook "Medical Instrumentation, Application and Design" 5th edition by John G. Webster
- Grading is split into three components with percentages of 30%, 30%, and 40%
- Office hours are on STT (days not specified) from 11:30 to 12:30 and 1:30 to 2:30
- MS Teams is used for course communication
Instrumentation Definition
- Instrumentation is the science and technology of designing, developing, and using devices or systems that measure, monitor, automate, and control physical processes.
- Instruments incorporate sensors, transducers, signal processors, and interfaces.
- These components are used to collect data, analyze variables like temperature and pressure, and regulate systems.
Medical Instrumentation
- Medical Instrumentation focuses on devices and systems that diagnose, monitor, treat, or research medical conditions
- These tools use advanced technologies to ensure precision, safety, and efficacy
- Examples are diagnostic tools, therapeutic devices, monitoring systems, and laboratory equipment.
Examples of Medical Instrumentation
- Diagnostic tools like MRI scanners, ECG monitors, and glucometers
- Therapeutic devices like surgical devices and therapeutic ultrasound
- Assistive devices like pacemakers and ventilators
- Monitoring systems like blood pressure cuffs and pulse oximeters
- Laboratory equipment such as automated analyzers and centrifuges
Generalized Medical Instrumentation System Components
- Sensor/Transducer converts physiological signals like biopotential, pressure, or temperature into electrical signals
- Signal Conditioning Unit amplifies, filters, and converts analog signals to digital (ADC) to improve signal quality
- Processing Unit performs computation, feature extraction, and digital signal processing
- Output Display & Recording Unit presents real-time data on screens, charts, or in electronic records
Operational Modes of Biomedical Instruments
- Direct Mode: Measures physiological parameters directly, like an ECG measuring heart activity
- Indirect Mode: Measures a secondary effect related to the physiological parameter; cardiac output estimation from respiration measurement
- Sampling Mode: Intermittently measures signals at specified intervals, as seen in glucose monitoring for diabetics
- Continuous Mode: Provides real-time, uninterrupted measurements, like in ICU patient monitoring systems
- Automatic Mode: Self-regulates and adjusts settings based on predefined thresholds, like insulin pumps do
- Manual Mode: Requires user operation and adjustment for specific tasks, for example manual defibrillators
- Real-time Mode: Measures in real-time to determine an impending cardiac arrest
- Delayed Time Mode: Cell cultures require several days before any output
Medical Measurement Constraints
- The signal to be measured puts constraints on how the signal is acquired and processed
- The instrumentation design is important
- Types of Constraints
- Biological Variability - The differences in physiological signals among individuals
- Environmental Factors - The effects of temperature, humidity, and electromagnetic interference on measurement accuracy
- Motion Artifacts - Movement of the patient affecting signal quality (e.g., muscle tremors affecting ECG readings)
- Time Lag - The delay between when the event occurs and when the measurement is displayed
- Signal/frequency ranges: Most medical measurands parameters are typically much lower than conventional sensing parameters (microvolts, mm Hg, low frequency)
- Interference and cross-talk: Noise from environment, instruments, etc.
- Other measurands affects measurement e.g., Cannot measure EEG without interference from EMG
- Safety and operator parameters must be considered
- Filtering is required
Classification of Medical Instrumentation Based on Various Factors
- Diagnostic Instruments (ECG, EEG, MRI, CT scan)
- Assistive Instruments (Pacemakers, infusion pumps, dialysis machines)
- Monitoring Instruments (Pulse oximeters, blood pressure monitors)
- Biopotential Instruments (ECG (heart), EEG (brain), EMG (muscles))
- Pressure Measurement Instruments (Blood pressure monitors, intracranial pressure sensors)
- Optical Instruments (Pulse oximeters, endoscopes)
- Imaging Systems (X-ray, MRI, CT, Ultrasound)
- Non-invasive Devices (Infrared thermometers, pulse oximeters)
- Quantity being sensed: pressure, flow or temperature
- Principle of transduction: resistive, inductive, capacitive, ultrasonic or electrochemical
- Organ systems: cardiovascular, pulmonary, nervous, endocrine
- Clinical specialties: pediatrics, obstetrics, cardiology or radiology
Compensation Techniques
- Compensation techniques enhance measurement accuracy and are used to counteract errors
- Calibration: Regular adjustment of device parameters to standard references
- Filtering: Removing noise from signals using low-pass filters in ECG to remove high-frequency noise
- Temperature Compensation: Adjusting sensor readings based on ambient temperature changes
- Motion Artifact Reduction: adaptive filtering corrects movement-induced errors
- Drift Compensation: Algorithms correct slow deviations in sensor performance over time
Temperature Compensation Details
- Temperature compensation adjusts sensor readings and electronic components to account for temperature variations
- Temperature fluctuations introduce errors, drifts, or signal distortions in physiological measurements
- ECG electrodes are an example of a need for compensation because skin impedance changes with temperature
Methods to Maintain Measurement Accuracy
- Apply software-based correction using calibration tables or compensation algorithms
- Thermistors inside glucose meters adjust readings based on measured ambient temperature
- Integrating internal temperature sensors to measure device/environment temperature
- MRI scanners use temperature sensors to correct coil conductivity changes
- Use hardware design adjustments
Drift Compensation
- Drift compensation corrects gradual changes in sensor readings or device performance over time
- These changes happen because of environmental factors, aging components, or physiological variability
- Drift can occur because of electronic component aging, electrode or sensor degradation, chemical sensor decay, or mechanical wear & tear
- ECG machines may have baseline drift while using their signals and/or electrode conductivity decreases
- Pulse Oximeters LED emitters degrade over time, requiring brightness adjustments
Drift Compensation Techniques
- Periodic Calibration calibrates devices against known standards at regular intervals, like how blood pressure monitors require recalibration to maintain accuracy
- Filtering Techniques use high-pass filters; for example, Butterworth filters in ECG eliminate slow signal drift
- Dual-Sensor Compensation uses two sensors (one for measurement and one as a reference) to detect drift
Biostatistics
- Biostatistics is crucial for data analysis and decision-making in biomedical instrumentation
- Medical research studies can be classified as:
- Observational, cross-sectional, or cohort studies
- Controlled or double-blind studies
Key Statistical Methods
- Mean, Median, Mode - Descriptive statistics to summarize data.
- Standard Deviation & Variance - Measure of data dispersion.
- Regression Analysis - Predicting health conditions based on multiple physiological parameters.
- Signal-to-Noise Ratio (SNR) - Evaluating signal clarity in medical instruments.
- Sensitivity & Specificity - Measuring diagnostic test accuracy.
- Receiver Operating Characteristic (ROC) Curves - Assessing classification performance of medical tests.
Statistical Definitions
- Mean/Average: Sum of all values divided by the number of observations
- Median: Middle value in ordered data; average of the two middle values if there is an even number of values
- Mode: Most frequently occurring value in a dataset; datasets can be unimodal, bimodal, or multimodal
- Standard Deviation (SD): Measure of variability, quantifies how much values deviate from the mean, assess normal vs. abnormal variability
- Correlation Coefficient (r): Measures the strength and direction of the relationship between two variables; ranges from -1 to +1; postive means directly correlated, negative means inversely correlated, 0 means no correlation
Static Characteristics
- Static characteristics describe a system's performance when the input is constant or changing very slowly
- This performance is in a steady-state condition, and the time effects are negligible or settled
- Key static characteristics include accuracy, precision, linearity, sensitivity, resolution, range, drift, hysteresis, and dead zone
Characteristics Definitions
- Accuracy: Closeness of the measured value to the true or accepted value
- For example: when the actual body temperature is 37.0°C, and the thermometer reads 37.1°C; this thermometer has good accuracy
- Precision: Consistency of a system to provide the same output for repeated applications of the same input
- Linearity: How closely the relationship between the input and output approximates a straight line, it must be directly proportional to the input
- Sensitivity: output change for a given change in input
- Resolution: Smallest change in input that can be detected and reliably indicated by a change in output
- Range: Limits within which the input and output of a system can vary
- Drift: Gradual change in output over time when the input is held constant, reflecting the system's ability to maintain its calibration
- Hysteresis: The output of a system not only depends on the current values, but depend on the past ones too
- Dead Zone: Range of input values for which there is no change in output
Dynamic Characteristics
- Dynamic characteristics of a system describe its behavior under time-varying conditions
- Changes in input, external disturbances, or transient states are time-varying states
- These characteristics Response Time, Settling Time, Overshoot, Rise Time, Delay/Lag,Stability, and Damping
Dynamic Characteristics Definitions
- Response Time: Time taken to react to a change in input or disturbance
- Settling Time: Time required to stabilize within a certain tolerance of the final value
- Overshoot: Maximum deviation beyond the desired steady-state value during transient response
- Rise Time: Time taken to transition from a low to high value
- Delay/Lag: Time delay between input application and system response
- Stability: Ability to return to equilibrium after a disturbance
- Damping: Degree to which oscillations decay over time