Podcast
Questions and Answers
What is the primary reason for returning an entire load for re-processing?
What is the primary reason for returning an entire load for re-processing?
- A small percentage of RMD in the load were not cleaned and/or dried effectively. (correct)
- All items in the load were not processed in a WD.
- The load was not properly documented.
- There is visible soil or staining on all items in the load.
What is the purpose of manually inspecting devices under magnification?
What is the purpose of manually inspecting devices under magnification?
- To verify the completion of device sets.
- To detect small pieces of bioburden or debris. (correct)
- To ensure all devices are properly disassembled.
- To check for corrosion and breakage.
What is the primary purpose of function testing devices?
What is the primary purpose of function testing devices?
- To check for damage or malfunction. (correct)
- To verify the cleanliness of devices.
- To ensure all devices are properly disassembled.
- To confirm the completion of device sets.
What is the purpose of a diathermy pin point tester in inspecting devices?
What is the purpose of a diathermy pin point tester in inspecting devices?
What is the primary function of a computerized track and trace system in a CSSD?
What is the primary function of a computerized track and trace system in a CSSD?
What should be done if a device is damaged or malfunctioning during inspection?
What should be done if a device is damaged or malfunctioning during inspection?
What should be checked on jointed RMD during the inspection process?
What should be checked on jointed RMD during the inspection process?
What is the purpose of documenting manually cleaned items and non-conformances?
What is the purpose of documenting manually cleaned items and non-conformances?
What is the result of scanning a barcode label in a computerized track and trace system?
What is the result of scanning a barcode label in a computerized track and trace system?
What is the alternative to a computerized track and trace system in a CSSD?
What is the alternative to a computerized track and trace system in a CSSD?
What could be the cause of excessive wetness in the load?
What could be the cause of excessive wetness in the load?
What should be done if a device was not properly disassembled before cleaning?
What should be done if a device was not properly disassembled before cleaning?
Which issue necessitates the entire load to be returned for re-processing?
Which issue necessitates the entire load to be returned for re-processing?
What should be checked during the final inspection of the load?
What should be checked during the final inspection of the load?
What actions should be taken if staining or residue is present after cycle completion?
What actions should be taken if staining or residue is present after cycle completion?
Flashcards are hidden until you start studying