Medical Device Maintenance and Inspection
15 Questions
3 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the primary reason for returning an entire load for re-processing?

  • A small percentage of RMD in the load were not cleaned and/or dried effectively. (correct)
  • All items in the load were not processed in a WD.
  • The load was not properly documented.
  • There is visible soil or staining on all items in the load.
  • What is the purpose of manually inspecting devices under magnification?

  • To verify the completion of device sets.
  • To detect small pieces of bioburden or debris. (correct)
  • To ensure all devices are properly disassembled.
  • To check for corrosion and breakage.
  • What is the primary purpose of function testing devices?

  • To check for damage or malfunction. (correct)
  • To verify the cleanliness of devices.
  • To ensure all devices are properly disassembled.
  • To confirm the completion of device sets.
  • What is the purpose of a diathermy pin point tester in inspecting devices?

    <p>To ensure the insulation of devices remains intact</p> Signup and view all the answers

    What is the primary function of a computerized track and trace system in a CSSD?

    <p>To accurately track devices and device trays through the decontamination process</p> Signup and view all the answers

    What should be done if a device is damaged or malfunctioning during inspection?

    <p>Report the issue to the line manager immediately.</p> Signup and view all the answers

    What should be checked on jointed RMD during the inspection process?

    <p>The tightness of the screws</p> Signup and view all the answers

    What is the purpose of documenting manually cleaned items and non-conformances?

    <p>To track the cleaning process for quality control.</p> Signup and view all the answers

    What is the result of scanning a barcode label in a computerized track and trace system?

    <p>A unique barcode label is generated with a specific serial number</p> Signup and view all the answers

    What is the alternative to a computerized track and trace system in a CSSD?

    <p>A manual system with a pre-printed tray checklist</p> Signup and view all the answers

    What could be the cause of excessive wetness in the load?

    <p>Blocked arms</p> Signup and view all the answers

    What should be done if a device was not properly disassembled before cleaning?

    <p>Return the entire tray for reprocessing</p> Signup and view all the answers

    Which issue necessitates the entire load to be returned for re-processing?

    <p>Spray arm rotation hindered</p> Signup and view all the answers

    What should be checked during the final inspection of the load?

    <p>Ensure there's no obvious damage, staining, or residue</p> Signup and view all the answers

    What actions should be taken if staining or residue is present after cycle completion?

    <p>Send the load back for reprocessing</p> Signup and view all the answers