Questions and Answers
What is the purpose of low water fuel cut-offs?
What is the purpose of low water fuel cut-offs?
According to the text, what does low water cut-off testing involve?
According to the text, what does low water cut-off testing involve?
What is the advantage of rapidly draining the float chamber during testing?
What is the advantage of rapidly draining the float chamber during testing?
What happens when water is expelled suddenly from the float chamber during testing?
What happens when water is expelled suddenly from the float chamber during testing?
Signup and view all the answers
What is the purpose of isolating the feedwater and allowing the boiler to steam off water during testing?
What is the purpose of isolating the feedwater and allowing the boiler to steam off water during testing?
Signup and view all the answers
What is the main purpose of low water cut-off testing?
What is the main purpose of low water cut-off testing?
Signup and view all the answers
What might happen if sediment is permitted to accumulate in the base of the float chamber?
What might happen if sediment is permitted to accumulate in the base of the float chamber?
Signup and view all the answers
Why is it important for the water level in the float chamber to quickly return to normal after testing?
Why is it important for the water level in the float chamber to quickly return to normal after testing?
Signup and view all the answers
What is the purpose of the flow switch in copper tubular and copper fin-tube boilers?
What is the purpose of the flow switch in copper tubular and copper fin-tube boilers?
Signup and view all the answers
Why are many forced circulation hot water boilers not equipped with low water cut-offs?
Why are many forced circulation hot water boilers not equipped with low water cut-offs?
Signup and view all the answers
How can the operation of the external low-water fuel cutoff be tested without draining the entire system?
How can the operation of the external low-water fuel cutoff be tested without draining the entire system?
Signup and view all the answers
How often does ASME BPVC VI recommend testing the low water cut-off of hot water heating boilers?
How often does ASME BPVC VI recommend testing the low water cut-off of hot water heating boilers?
Signup and view all the answers
What is recommended if the operating parameters of the operating limit switch differ from the expected range?
What is recommended if the operating parameters of the operating limit switch differ from the expected range?
Signup and view all the answers
When can the high temperature cut-off be tested during normal boiler operation?
When can the high temperature cut-off be tested during normal boiler operation?
Signup and view all the answers
What is a recommended step to test the high temperature cut-off?
What is a recommended step to test the high temperature cut-off?
Signup and view all the answers
What does ASME BPVC IV restrict the water temperature of hot water heating boilers to?
What does ASME BPVC IV restrict the water temperature of hot water heating boilers to?
Signup and view all the answers
How often should the low water cut-off test be completed for power boilers, according to ASME CSD-1?
How often should the low water cut-off test be completed for power boilers, according to ASME CSD-1?
Signup and view all the answers
What is the recommended frequency for completing the low water cut-off test for heating boilers, according to ASME CSD-1?
What is the recommended frequency for completing the low water cut-off test for heating boilers, according to ASME CSD-1?
Signup and view all the answers
What is the critical action to take if the boiler does not trip at or above the lowest visible part of the gauge glass during a falling water level?
What is the critical action to take if the boiler does not trip at or above the lowest visible part of the gauge glass during a falling water level?
Signup and view all the answers
How can the operation of the make-up valve in combined feeder/cut-off controls be checked?
How can the operation of the make-up valve in combined feeder/cut-off controls be checked?
Signup and view all the answers
What should be done annually to low water cut-offs, pump controls, and water feeders?
What should be done annually to low water cut-offs, pump controls, and water feeders?
Signup and view all the answers
What should be done if the operating parameters differ from the expected range for the operating limit switch?
What should be done if the operating parameters differ from the expected range for the operating limit switch?
Signup and view all the answers
How can the high-pressure cut-off control be tested?
How can the high-pressure cut-off control be tested?
Signup and view all the answers
What action should be taken if the high-pressure cut-off control does not trip the boiler at a pressure higher than the set point of the operating limit control, but lower than the safety valve popping pressure?
What action should be taken if the high-pressure cut-off control does not trip the boiler at a pressure higher than the set point of the operating limit control, but lower than the safety valve popping pressure?
Signup and view all the answers