Boiler Low Water Level Fuel Cut-off Equipment

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the purpose of the low water fuel cut-off (LWCO) in a boiler?

  • To regulate the fuel flow into the boiler
  • To detect the level of water in the boiler and shut off the burner if the water level drops to an unsafe level (correct)
  • To increase the pressure in the boiler
  • To cool down the boiler system

Which type of boilers do not require low water fuel cut-offs?

  • Electrode-type electric boilers (correct)
  • High-pressure boilers
  • Gas-fired boilers
  • Boilers with fin tube design

What is the lowest permissible water level (LPWL) for a boiler?

  • The minimum water level allowed in the boiler
  • The maximum water level allowed in the boiler
  • The lowest water level at which a boiler can be safely operated (correct)
  • A level determined by the fuel type used in the boiler

Why are low water fuel cut-offs considered an important safety control for boilers?

<p>To prevent overheating and weakening of pressure-retaining parts (C)</p> Signup and view all the answers

What is essential to consider when repairing or replacing LWCOs in a boiler?

<p>Maximum allowable working pressures (MAWP) (C)</p> Signup and view all the answers

What does a low water fuel cut-off (LWCO) directly detect in a boiler?

<p>Level of water in the boiler (B)</p> Signup and view all the answers

What is the function of the low water fuel cut-off when the water level drops to level C?

<p>Open the burner circuit and energize the alarm circuit (D)</p> Signup and view all the answers

What happens to the low water fuel cut-off when the water level drops below the upper probe in the electric probe type cut-off?

<p>The switch opens, interrupting the power supply to the fuel valve (B)</p> Signup and view all the answers

What is a possible cause of rapidly falling water level in the boiler?

<p>Interruption of the water supply to the feedwater pump (C)</p> Signup and view all the answers

How does the low water fuel cut-off respond when the water level drops to level B during normal operation?

<p>The control switch closes and the feedwater pump starts (C)</p> Signup and view all the answers

What is the advantage of the electric probe type low water fuel cut-off?

<p>It contains no moving parts, reducing mechanical failure (D)</p> Signup and view all the answers

What does Figure 7 show in relation to low water fuel cut-off?

<p>Operation of a low water fuel cutoff actuated by a float and magnet (B)</p> Signup and view all the answers

What triggers the alarm circuit in a low water fuel cut-off device?

<p>The burner circuit opening (D)</p> Signup and view all the answers

In what scenario will manual reset of a low water fuel cut-off possibly be required?

<p>When the switch fails to shut down the boiler at low water level (C)</p> Signup and view all the answers