API 653 Covers which of the following activities?

  • Tank design
  • tank fabrication
  • tank operation
  • tank reconstruction (correct)

Corroded roof plates on a fixed roof tank shall not be less than

  • designers recomendation
  • 0.090" in any 100 inch squared area (correct)
  • 0.050" at any point
  • tmin averaged over the critical length

A new nameplate should be added to a tank after

  • either major repairs or major alterations
  • either major alterations or tank reconstruction
  • it has been relocated
  • it has been reconstructed (correct)

for a reconstructed tank, the shell thickness readings used to determine the allowable shell height must have been taken within the last:

<p>180 days (D)</p> Signup and view all the answers

the impressed current sources of a cathodic protection system should be checked (to see if still operating) every

<p>two months (B)</p> Signup and view all the answers

which of the following is part of the critical zone

<p>the bottom within 3&quot; of the shell (B)</p> Signup and view all the answers

a tank is 20 years old and has a bottom thickness of 0.170". Original bottom thickness was 0.250". Determine the interval for the next internal inspections

<p>17.5 years (C)</p> Signup and view all the answers

Widely scattered pitting in a tank shell can be ignored if the extent of the pitting does not exceed

<p>2 inch in any vertical 8 inches (D)</p> Signup and view all the answers

Which of the following is an advantage of the galvanic cathodic protection systems

<p>annual maintenance costs are generally low (B)</p> Signup and view all the answers

Hot taps are permitted:

<p>only in the liquid section of the tank (C)</p> Signup and view all the answers

An API 653 hydro test shall be held for at least

<p>24 hours (D)</p> Signup and view all the answers

Which of the following activities is considered an alteration in API 653

<p>the addition of a 16 NPS nozzle (C)</p> Signup and view all the answers

repaired or replaced bottom welds shall be examined with either a vacuum box or by using

<p>a tracer gas test (A)</p> Signup and view all the answers

welding procedures for tank repairs to the shell should be qualified in accordance with

<p>ASME Section IX (C)</p> Signup and view all the answers

A lap patch is installed on a tank bottom and the patch plate crosses a tank bottom weld. what is the minimum dimension for this patch plate

<p>12&quot; (D)</p> Signup and view all the answers

API 653 is intended to be used by Owner/Operator organizations that

<p>have access to engineers and inspectors (B)</p> Signup and view all the answers

Which of the following tests are required when qualifying a weld procedure

<p>a minimum of 2 tension tests (D)</p> Signup and view all the answers

calcining of a tanks concrete ringwall can occur when the concrete is

<p>exposed to a high temperature (A)</p> Signup and view all the answers

Which of the following does not increase the risk of brittle fracture

<p>change to a product with increased viscosity (C)</p> Signup and view all the answers

Which external floating roof is most susceptible to sinking

<p>pan (A)</p> Signup and view all the answers

All new materials used for repairs must conform to

<p>current applicable standard (D)</p> Signup and view all the answers

which of the following is not considered one of the major types of inspection records

<p>operation history (A)</p> Signup and view all the answers

Which tank component in a reconstructed tank must be identified by material type

<p>bottom plates welded to the shell (C)</p> Signup and view all the answers

an F on the radiograph indicates

<p>the IQI is placed on the film side (D)</p> Signup and view all the answers

if an atmospheric tank is air tested, the pressure should not exceed

<p>2 inches of water (B)</p> Signup and view all the answers

the welding position 4G is a(n)

<p>overhead plate groove weld (C)</p> Signup and view all the answers

A new tank bottom was installed above the existing tank bottom. Now the spacing between a nozzle and the new bottom is below the minimum requirements of API 650. Which of the following is not an acceptable method of repair

<p>remove the existing reinforcement pad (B)</p> Signup and view all the answers

During a tank repair, if API 653 conflicts with the design standard, which standard governs?

<p>API 653 (C)</p> Signup and view all the answers

All reconstruction work must be authorized by the

<p>either the engineer or inspector (D)</p> Signup and view all the answers