Questions and Answers
How should you pre-treat the eye before taking measurements with the Digital Caliper?
How should you pre-treat the eye before taking measurements with the Digital Caliper?
With anesthetic drops
At what position should the patient be when taking the measurement with the Digital Caliper?
At what position should the patient be when taking the measurement with the Digital Caliper?
Supine position
Where should the Digital Caliper measurement be taken from and to in the eye?
Where should the Digital Caliper measurement be taken from and to in the eye?
Middle of the limbus to middle of the limbus
What should be used to validate the caliper measurement of the w-to-w?
What should be used to validate the caliper measurement of the w-to-w?
Signup and view all the answers
What should be done if there is a discrepancy in the w-to-w measurement between eyes?
What should be done if there is a discrepancy in the w-to-w measurement between eyes?
Signup and view all the answers
How should you read the caliper measure when using the Digital Caliper?
How should you read the caliper measure when using the Digital Caliper?
Signup and view all the answers
What is one method to measure the W-to-W and vault of PC-PHAKIC IOL?
What is one method to measure the W-to-W and vault of PC-PHAKIC IOL?
Signup and view all the answers
What issue can high vault post-operatively cause?
What issue can high vault post-operatively cause?
Signup and view all the answers
What complication may arise from low vault post-operatively?
What complication may arise from low vault post-operatively?
Signup and view all the answers
What management approach can be taken for high vault exceeding 1000 microns?
What management approach can be taken for high vault exceeding 1000 microns?
Signup and view all the answers
What is the regular limit for low vault measurement?
What is the regular limit for low vault measurement?
Signup and view all the answers
How can a low vault be managed if there is peripheral touch despite a central vault of 100 or 150 microns?
How can a low vault be managed if there is peripheral touch despite a central vault of 100 or 150 microns?
Signup and view all the answers
What is the recommended minimum internal ACD measurement to avoid errors when using the EYECRYL™ PHAKIC IOL?
What is the recommended minimum internal ACD measurement to avoid errors when using the EYECRYL™ PHAKIC IOL?
Signup and view all the answers
Name some of the tools that can be used to measure ACD for proper evaluation before using the EYECRYL™ PHAKIC IOL.
Name some of the tools that can be used to measure ACD for proper evaluation before using the EYECRYL™ PHAKIC IOL.
Signup and view all the answers
Why is the measurement of Intra-Ocular Pressure (IOP) important when considering the use of PC Phakic IOL like EYECRYL™?
Why is the measurement of Intra-Ocular Pressure (IOP) important when considering the use of PC Phakic IOL like EYECRYL™?
Signup and view all the answers
What screening tests should be performed to evaluate the risk of Glaucoma before using the EYECRYL™ PHAKIC IOL?
What screening tests should be performed to evaluate the risk of Glaucoma before using the EYECRYL™ PHAKIC IOL?
Signup and view all the answers
Why is it important to evaluate dry eye condition before considering the EYECRYL™ PHAKIC IOL?
Why is it important to evaluate dry eye condition before considering the EYECRYL™ PHAKIC IOL?
Signup and view all the answers
What is the recommended timeframe for discontinuing soft contact lenses and RGP contact lenses before corneal topography when planning to use EYECRYL™ PHAKIC IOL?
What is the recommended timeframe for discontinuing soft contact lenses and RGP contact lenses before corneal topography when planning to use EYECRYL™ PHAKIC IOL?
Signup and view all the answers
Study Notes
Preparing for Measurements with Digital Caliper
- The eye should be pre-treated before taking measurements with the Digital Caliper.
- The patient should be in a seated position when taking the measurement with the Digital Caliper.
- The Digital Caliper measurement should be taken from the white-to-white (w-to-w) of the eye.
Validating Caliper Measurements
- The caliper measurement of the w-to-w should be validated using a keratometer or IOLMaster.
- If there is a discrepancy in the w-to-w measurement between eyes, the measurement should be re-taken and re-validated.
Reading Caliper Measurements
- When using the Digital Caliper, the caliper measure should be read in a way that is perpendicular to the eye.
Measuring W-to-W and Vault of PC-PHAKIC IOL
- One method to measure the W-to-W and vault of PC-PHAKIC IOL is by using a digital caliper.
Complications of High and Low Vault
- High vault post-operatively can cause glare and halos.
- Low vault post-operatively may cause peripheral touch.
- If high vault exceeds 1000 microns, a management approach can be taken to reduce the vault.
- The regular limit for low vault measurement is 100-150 microns.
Managing Low Vault
- If there is peripheral touch despite a central vault of 100 or 150 microns, a low vault can be managed by adjusting the vault height.
Measuring Internal ACD for EYECRYL™ PHAKIC IOL
- The recommended minimum internal ACD measurement to avoid errors when using the EYECRYL™ PHAKIC IOL is 12.5 mm.
- Tools that can be used to measure ACD for proper evaluation before using the EYECRYL™ PHAKIC IOL include the IOLMaster and ultrasound.
Importance of Measuring IOP and Screening for Glaucoma
- Measuring Intra-Ocular Pressure (IOP) is important when considering the use of PC Phakic IOL like EYECRYL™ to avoid complications.
- Screening tests should be performed to evaluate the risk of Glaucoma before using the EYECRYL™ PHAKIC IOL.
Evaluating Dry Eye Condition
- It is important to evaluate dry eye condition before considering the EYECRYL™ PHAKIC IOL to avoid complications.
Discontinuing Contact Lenses before Corneal Topography
- Soft contact lenses should be discontinued for 7 days and RGP contact lenses for 30 days before corneal topography when planning to use EYECRYL™ PHAKIC IOL.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
This quiz covers the equipment and tools used for measuring internal anterior chamber depth (ACD) in ophthalmology, with a focus on ensuring ACD from the endothelium is not less than 2.8 mm. Learn about devices such as Orbscan® ll, Pentacam® HR, and IOL Master® 500 & 700 commonly used for this purpose.