Podcast
Questions and Answers
According to the procedure, what is the minimum number of fire protection personnel required before an interior fire attack can be made when the fire has progressed beyond the incipient stage?
According to the procedure, what is the minimum number of fire protection personnel required before an interior fire attack can be made when the fire has progressed beyond the incipient stage?
- 3 fire protection personnel
- 2 fire protection personnel
- 5 fire protection personnel
- 4 fire protection personnel (correct)
What is the primary requirement for fire protection personnel located outside the IDLH atmosphere?
What is the primary requirement for fire protection personnel located outside the IDLH atmosphere?
- They must actively monitor the status of personnel inside the IDLH atmosphere
- They must be equipped with appropriate retrieval equipment (correct)
- They must remain in communication with personnel inside the IDLH atmosphere
- They must have a complete set of protective clothing and SCBA readily accessible
What is the requirement for the two fire protection personnel entering the IDLH (Immediately Dangerous to Life or Health) atmosphere?
What is the requirement for the two fire protection personnel entering the IDLH (Immediately Dangerous to Life or Health) atmosphere?
- They must remain within visual contact of each other at all times
- They must remain in visual or voice contact with each other at all times (correct)
- They must remain in radio contact with each other at all times
- They must remain in voice contact with each other at all times
What is the requirement for one of the outside fire protection personnel regarding monitoring duties?
What is the requirement for one of the outside fire protection personnel regarding monitoring duties?
What is the requirement for the two fire protection personnel remaining outside the IDLH atmosphere?
What is the requirement for the two fire protection personnel remaining outside the IDLH atmosphere?
What is the requirement for the second outside fire protection person regarding additional duties?
What is the requirement for the second outside fire protection person regarding additional duties?
Which of the following is an exception to the 2-in/2-out rule?
Which of the following is an exception to the 2-in/2-out rule?
What is the requirement for communication between outside and inside fire protection personnel?
What is the requirement for communication between outside and inside fire protection personnel?
What is the requirement for fire protection personnel engaged in interior structural fire fighting?
What is the requirement for fire protection personnel engaged in interior structural fire fighting?
What is the requirement regarding the use of signal lines (ropes) for communication during interior fire fighting?
What is the requirement regarding the use of signal lines (ropes) for communication during interior fire fighting?
What is the requirement for outside fire protection personnel regarding protective equipment?
What is the requirement for outside fire protection personnel regarding protective equipment?
What does the term 'IDLH atmosphere' refer to?
What does the term 'IDLH atmosphere' refer to?