Podcast
Questions and Answers
The standard IEC 62305-1 deals with protection against thunderstorms.
The standard IEC 62305-1 deals with protection against thunderstorms.
True
The publication year of IEC 62305-1 is 2010.
The publication year of IEC 62305-1 is 2010.
True
Reproduction or networking of IEC 62305-1 content is allowed without a license from IHS.
Reproduction or networking of IEC 62305-1 content is allowed without a license from IHS.
False
The standard IEC 62305-1 includes a section on lightning current parameters.
The standard IEC 62305-1 includes a section on lightning current parameters.
Signup and view all the answers
The ISBN of IEC 62305-1 is 978-2-88912-280-6.
The ISBN of IEC 62305-1 is 978-2-88912-280-6.
Signup and view all the answers
Protection against lightning is not covered within the scope of IEC 62305-1.
Protection against lightning is not covered within the scope of IEC 62305-1.
Signup and view all the answers
Protection measures to reduce injury of living beings by electric shock are discussed in section 6.1.
Protection measures to reduce injury of living beings by electric shock are discussed in section 6.1.
Signup and view all the answers
Sources and types of damage to a structure are covered in section 5.1.2.
Sources and types of damage to a structure are covered in section 5.1.2.
Signup and view all the answers
Section 8.3 discusses the basic criteria for protection of structures.
Section 8.3 discusses the basic criteria for protection of structures.
Signup and view all the answers
Economic justification of lightning protection is covered in section 6.2.
Economic justification of lightning protection is covered in section 6.2.
Signup and view all the answers
Section 7.4 discusses protection measures to reduce injury of living beings by electric shock.
Section 7.4 discusses protection measures to reduce injury of living beings by electric shock.
Signup and view all the answers
General protection measures are discussed in section 7.1.
General protection measures are discussed in section 7.1.
Signup and view all the answers
Lightning protection levels are denoted by LPZ in the text.
Lightning protection levels are denoted by LPZ in the text.
Signup and view all the answers
Annex B provides parameters of lightning current for analysis purposes.
Annex B provides parameters of lightning current for analysis purposes.
Signup and view all the answers
Protection to reduce the failure of internal systems is covered in section 8.4.1.
Protection to reduce the failure of internal systems is covered in section 8.4.1.
Signup and view all the answers
Annex E discusses surges due to lightning at different installation points.
Annex E discusses surges due to lightning at different installation points.
Signup and view all the answers
Figure 2 in the text shows the connection between various parts of IEC 62305.
Figure 2 in the text shows the connection between various parts of IEC 62305.
Signup and view all the answers
The bibliography is located at page 23 of the text.
The bibliography is located at page 23 of the text.
Signup and view all the answers
Study Notes
IEC 62305-1: Protection Against Lightning
- Published by the International Electrotechnical Commission (IEC) in 2010
- Specifies general principles for protection against lightning
Structure of the Standard
- Consists of several sections, including scope, normative references, terms and definitions, and protection measures
- Includes annexes on lightning current parameters, simulation, and test parameters
Lightning Current Parameters
- Parameters include peak current, charge transfer, and specific energy
- Important for designing and testing lightning protection systems
Damage Due to Lightning
- Can cause physical damage to structures and injury to living beings
- Types of damage include direct strike, side flash, and lightning-induced surges
- Economic justification for lightning protection includes reducing loss of life and property
Protection Measures
- Includes reducing injury from electric shock, physical damage, and failure of electrical and electronic systems
- Selection of protection measures depends on the type of structure and its occupancy
- Measures include earthing, bonding, and surge protection devices
Basic Criteria for Protection of Structures
- Aimed at reducing physical damage, injury, and failure of internal systems
- Includes protection to reduce life hazard and failure of electrical systems
- Parameters for protection include LPL (Lightning Protection Level) and LPZ (Lightning Protection Zone)
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge on the International Standard IEC 62305-1 Edition 2.0 from 2010-12 regarding protection against lightning and general principles. Explore key concepts related to lightning protection outlined in the standard.