What should be done before starting a hot water boiler?

  • Inspect the fuel gauge
  • Review the manufacturer recommendations for air conditioning
  • Prepare the boiler plant auxiliaries (correct)
  • Check the outdoor temperature
  • What is an excellent reference for heating boiler operating practices?

  • ASME VI Recommended Rules for the Care and Operation of Heating Boilers (correct)
  • Manufacturer's warranty document
  • Local building code regulations
  • Boiler maintenance checklist
  • What should be the position of the boiler control switch before starting the boiler?

  • Off (correct)
  • Standby
  • Auto
  • On
  • What does a single boiler downfeed hot water system may not have?

    <p>Inlet and outlet isolation valves</p> Signup and view all the answers

    What should be filled with treated water in a hot water system startup?

    <p>Boiler and heating system</p> Signup and view all the answers

    What covers the main steps that should be performed when starting a hot water boiler?

    <p>ASME VI Recommended Rules for the Care and Operation of Heating Boilers</p> Signup and view all the answers

    What procedure is important to follow before starting a hot water boiler?

    <p>Site-specific standard operating procedures review</p> Signup and view all the answers

    1

    Signup and view all the answers

    How many boilers do smaller hot water systems may have?

    <p>Single boiler only</p> Signup and view all the answers

    What should be done to supply power to the boiler?

    <p>Close the main disconnect switch</p> Signup and view all the answers

    What should be done if the boiler has a continuous pilot?

    <p>Light the pilot manually</p> Signup and view all the answers

    What should be done if the flame at low fire provides insufficient heat to reach normal operating temperature after 30 minutes?

    <p>Gradually increase the firing rate using the manual firing rate control</p> Signup and view all the answers

    What should be done before increasing fuel input in the boiler?

    <p>Warm the entire water content of the system and boiler</p> Signup and view all the answers

    What should be done to limit differential expansion when warming up a boiler?

    <p>Fire the boiler at low fire until water temperature reaches its normal operating range</p> Signup and view all the answers

    What should be checked when the burner shuts down?

    <p>Water pressure on the tridicator gauge and safety relief valve for evidence of leaking</p> Signup and view all the answers

    What should be done if equipped with a high-low firing rate control?

    <p>Place the boiler on low fire</p> Signup and view all the answers

    What is meant by 'cutting in' in a multiple boiler plant?

    <p>Adding a previously non-operating boiler to a system already in operation</p> Signup and view all the answers

    What should be ensured when using a common expansion tank for all boilers?

    <p>The stop valves in both supply and return lines to the boiler are open during warmup.</p> Signup and view all the answers

    What is done to warm a cold boiler to system temperature before firing it?

    <p>Slowly open the inlet valve to the cold boiler.</p> Signup and view all the answers