What is the minimum psi that at least one tank gauge should indicate for the air fill station at Station 22?
Who is responsible for inspecting the air fill station pressure each morning?
What action is required if the cascade system on Reserve Tower 22 shows failing psi levels?
What is the maximum psi the cascade on Reserve Tower 22 should be filled to?
Signup and view all the answers
What time must the air fill station pressure be inspected by?
Signup and view all the answers
What must personnel do prior to operating the compressor?
Signup and view all the answers
What indicates the successful functionality of the cascade system on Reserve Tower 22?
Signup and view all the answers
What procedure must be followed for the compressor operation?
Signup and view all the answers
What is the minimum number of oxygen cylinders required at Station 22's oxygen fill station to avoid contacting the EMS Officer?
Signup and view all the answers
What is the maximum pressure to which oxygen cylinders can be refilled?
Signup and view all the answers
What is the maximum time period for hydrostatic testing of steel, aluminum, and carbon composite oxygen cylinders?
Signup and view all the answers
Which of the following types of cylinders must be hydrostatically tested every 3 years?
Signup and view all the answers
Which type of oxygen cylinder requires a fragmentation shield when being refilled at Station 22 using the oxygen cascade system?
Signup and view all the answers
When refilling SCBA or SCUBA cylinders using the Reserve Tower 22 cascade system, which type of fragmentation shield is required?
Signup and view all the answers
When refilling oxygen cylinders at Station 22, what is the primary safety measure that should be taken regarding the regulator?
Signup and view all the answers
What is the main reason for using a fragmentation shield during the refilling of oxygen cylinders?
Signup and view all the answers
Study Notes
Air and Oxygen Fill Systems
- The air fill station at Station 22 is located in the hose room and must be inspected by the Company Officer of Engine 22 and/or Tower 22 by 0900 hours every morning.
- The tank gauges on the fill station should indicate 4,500 psi or greater, and at least one of the tank gauges should indicate at least 5,500 psi.
- Only authorized personnel who are trained to operate the breathing air compressor can turn it on.
- The compressor must be operated according to the manufacturer's specific operations.
Cascade System (Reserve Tower 22)
- The cascade system on Reserve Tower 22 must be inspected during apparatus inspection every morning.
- All tank gauges should indicate 4,500 psi or greater, and at least one of the tank gauges should indicate 5,500 psi or greater.
- If both conditions are not present, it must be reported to the Company Officer of Engine 22 and/or Tower 22, and arrangements will be made to have the cascade filled.
- The cascade on Reserve Tower 22 is to be filled to 6,000 psi using Station 22's fill station and the station air compressor.
Oxygen Cascade System
- The oxygen fill station bottle status at Station 22 must be inspected every morning by 0900 hours.
- If the system does not have at least 6 cylinders with greater than 300 psi, the EMS Officer must be contacted.
Refilling Guidelines
- No oxygen, SCBA, or SCUBA cylinders are to be refilled higher than their rated capacity.
- All tank and cylinder hydrostatic stamps must be checked and must be within approved limits (5 years for all steel, aluminum, and carbon composite, and 3 years for all fiberglass wrapped cylinders and carbon composite cylinders manufactured in 2000 or older) in order to be filled.
- The regulator must be adjusted to the appropriate pressure setting prior to flowing any air into the cylinder or tank.
- Tanks or cylinders must be placed in their appropriate protective shield when being refilled.
- All small oxygen tanks must be refilled utilizing the fragmentation shield when using the Station 22 oxygen cascade system.
- All SCBA and SCUBA cylinders must be refilled utilizing the fragmentation shield when using the Station 22 fill station or the Reserve Tower 22 cascade system.
- Approved eye protection must be worn during the refilling of all small oxygen tanks, SCBA, and SCUBA tanks.