Hoffman Estates FD Air and Oxygen Fill Systems
16 Questions
0 Views

Hoffman Estates FD Air and Oxygen Fill Systems

Created by
@LighterElm

Questions and Answers

What is the minimum psi that at least one tank gauge should indicate for the air fill station at Station 22?

  • 4,000 psi
  • 5,500 psi (correct)
  • 5,000 psi
  • 6,000 psi
  • Who is responsible for inspecting the air fill station pressure each morning?

  • The Company Officer of Engine 22 and/or Tower 22 (correct)
  • Any firefighter on duty
  • The apparatus operators
  • The Chief of Station 22
  • What action is required if the cascade system on Reserve Tower 22 shows failing psi levels?

  • Condition does not require reporting
  • No action is necessary if personnel are present
  • The compressor must immediately be shut down
  • A report should be made to a higher authority (correct)
  • What is the maximum psi the cascade on Reserve Tower 22 should be filled to?

    <p>6,000 psi</p> Signup and view all the answers

    What time must the air fill station pressure be inspected by?

    <p>0900 hours</p> Signup and view all the answers

    What must personnel do prior to operating the compressor?

    <p>Have authorization and training</p> Signup and view all the answers

    What indicates the successful functionality of the cascade system on Reserve Tower 22?

    <p>One gauge above 4,500 psi and another above 5,500 psi</p> Signup and view all the answers

    What procedure must be followed for the compressor operation?

    <p>Follow the manufacturer's specific operations</p> Signup and view all the answers

    What is the minimum number of oxygen cylinders required at Station 22's oxygen fill station to avoid contacting the EMS Officer?

    <p>6</p> Signup and view all the answers

    What is the maximum pressure to which oxygen cylinders can be refilled?

    <p>The pressure rating of the cylinder</p> Signup and view all the answers

    What is the maximum time period for hydrostatic testing of steel, aluminum, and carbon composite oxygen cylinders?

    <p>5 years</p> Signup and view all the answers

    Which of the following types of cylinders must be hydrostatically tested every 3 years?

    <p>Fiberglass wrapped cylinders</p> Signup and view all the answers

    Which type of oxygen cylinder requires a fragmentation shield when being refilled at Station 22 using the oxygen cascade system?

    <p>All of the above</p> Signup and view all the answers

    When refilling SCBA or SCUBA cylinders using the Reserve Tower 22 cascade system, which type of fragmentation shield is required?

    <p>Reserve Tower 22 fragmentation shield</p> Signup and view all the answers

    When refilling oxygen cylinders at Station 22, what is the primary safety measure that should be taken regarding the regulator?

    <p>Ensure the regulator is set to the appropriate pressure before flowing air into the cylinder.</p> Signup and view all the answers

    What is the main reason for using a fragmentation shield during the refilling of oxygen cylinders?

    <p>To protect personnel from potential fragments in the event of a cylinder rupture.</p> Signup and view all the answers

    Study Notes

    Air and Oxygen Fill Systems

    • The air fill station at Station 22 is located in the hose room and must be inspected by the Company Officer of Engine 22 and/or Tower 22 by 0900 hours every morning.
    • The tank gauges on the fill station should indicate 4,500 psi or greater, and at least one of the tank gauges should indicate at least 5,500 psi.
    • Only authorized personnel who are trained to operate the breathing air compressor can turn it on.
    • The compressor must be operated according to the manufacturer's specific operations.

    Cascade System (Reserve Tower 22)

    • The cascade system on Reserve Tower 22 must be inspected during apparatus inspection every morning.
    • All tank gauges should indicate 4,500 psi or greater, and at least one of the tank gauges should indicate 5,500 psi or greater.
    • If both conditions are not present, it must be reported to the Company Officer of Engine 22 and/or Tower 22, and arrangements will be made to have the cascade filled.
    • The cascade on Reserve Tower 22 is to be filled to 6,000 psi using Station 22's fill station and the station air compressor.

    Oxygen Cascade System

    • The oxygen fill station bottle status at Station 22 must be inspected every morning by 0900 hours.
    • If the system does not have at least 6 cylinders with greater than 300 psi, the EMS Officer must be contacted.

    Refilling Guidelines

    • No oxygen, SCBA, or SCUBA cylinders are to be refilled higher than their rated capacity.
    • All tank and cylinder hydrostatic stamps must be checked and must be within approved limits (5 years for all steel, aluminum, and carbon composite, and 3 years for all fiberglass wrapped cylinders and carbon composite cylinders manufactured in 2000 or older) in order to be filled.
    • The regulator must be adjusted to the appropriate pressure setting prior to flowing any air into the cylinder or tank.
    • Tanks or cylinders must be placed in their appropriate protective shield when being refilled.
    • All small oxygen tanks must be refilled utilizing the fragmentation shield when using the Station 22 oxygen cascade system.
    • All SCBA and SCUBA cylinders must be refilled utilizing the fragmentation shield when using the Station 22 fill station or the Reserve Tower 22 cascade system.
    • Approved eye protection must be worn during the refilling of all small oxygen tanks, SCBA, and SCUBA tanks.