High ex can be used to augment or replace ____ nozzles, and in many cases It’s safer due to its ability to be applied from a safer area.

Cellar

High ex is an extremely expanded solution of water, air, and _____ (____:1 to ____:1 ratio)

Detergent, 400, 1000

High ex foams primary function is to ___ an enclosure, thus pushing out the products of combustion and replacing them with a water solution, which will cool the source of fire.

Fill

When high ex foam is discharged into an area, an opening must be provided near the ____ ceiling spaces, preferably _____ the place where the foam is being injected.

<p>Upper, opposite</p> Signup and view all the answers

What is not one of the three factors to be present for high ex foam to work?

<p>There has to be enough heat to evaporate the foam and allow it to work</p> Signup and view all the answers

In some cases of structural stability seems assured, as is likely for a ____ fire in a ______ concrete building, it may be possible and beneficial to gain control of the fire and then send crews in with hand lines for final extinguishment

<p>Cellar, reinforced</p> Signup and view all the answers

Light travels only a ___ feet in high ex foam and is widely diffused through all the bubbles

<p>Few</p> Signup and view all the answers

Sound is also muffled; the already muffled voices from within the SCBA facepieces can barely be heard _ or _ ft away

<p>3,4</p> Signup and view all the answers

Firefighters can breakdown the foam blanket by ______ movement or by use of a hose stream on ____ setting.

<p>Substantial, fog</p> Signup and view all the answers

What is not a circumstance listed for allowing members to enter a high ex foam blanket?

<p>Substantial overhaul is needed to fully extinguish</p> Signup and view all the answers

Balloon framing was very common in homes built in the late ____ and early ____, particularly in the east and _____

<p>1800s, 1900s, Midwest</p> Signup and view all the answers

The second floor joist in balloon framing rest on a small board (__in) that is notched into the upright 2x4s called a _____ board.

<p>1X4, ledger</p> Signup and view all the answers

If fire is found in the walls of a ballon frame from the cellar fire the first line is stretched to cellar, second as backup and the third line is stretched to the ___ floor or ____

<p>Top, attic</p> Signup and view all the answers

Start on the ____ walls and the plumbing wall behind the ____.

<p>Outer, toilet</p> Signup and view all the answers

A fire in a cellar or basement of a ballon frame house is one of the few cases where ________ in a private dwelling is justified.

<p>Roof ventilation</p> Signup and view all the answers

When high ex foam is discharged into an area an opening must be provided near the ____ ceiling spaces, preferably opposite the place where the foam is being injected

<p>Upper</p> Signup and view all the answers

If the fire in a basement or cellar is found in a ballon frame send the third line to the ____ or the attic

<p>Top floor</p> Signup and view all the answers

Basement fires are one of the few fires where residential vertical ventilation is needed to stop the fire from going into the attic or _____