libraries
All fire alarm boxes must be painted ___
All fire alarm boxes must be painted ___
red
The minimum number of fire alarm boxes required on each floor of a building is ___
The minimum number of fire alarm boxes required on each floor of a building is ___
1
In large buildings, alarm boxes may not be more than ___ feet from each other
In large buildings, alarm boxes may not be more than ___ feet from each other
Signup and view all the answers
Alarm boxes must be mounted ___ feet above the floor
Alarm boxes must be mounted ___ feet above the floor
Signup and view all the answers
In an emergency, a fireguard's most effective quality is their ___
In an emergency, a fireguard's most effective quality is their ___
Signup and view all the answers
In a fire emergency, the fire department may be notified by
In a fire emergency, the fire department may be notified by
Signup and view all the answers
An exit aisle at least ___ feet wide is required at all locations
An exit aisle at least ___ feet wide is required at all locations
Signup and view all the answers
Areas that must not be obstructed include ___
Areas that must not be obstructed include ___
Signup and view all the answers
Buildings must be checked ___ for potential fire hazards
Buildings must be checked ___ for potential fire hazards
Signup and view all the answers
Fire alarm boxes must be checked ___
Fire alarm boxes must be checked ___
Signup and view all the answers
Sprinkler heads are activated ___
Sprinkler heads are activated ___
Signup and view all the answers
Sprinkler heads that have been activated must be ___
Sprinkler heads that have been activated must be ___
Signup and view all the answers
The charge of a fire extinguisher can be checked by ___
The charge of a fire extinguisher can be checked by ___
Signup and view all the answers
Most sprinkler and standpipe systems must be inspected ___
Most sprinkler and standpipe systems must be inspected ___
Signup and view all the answers
The Fire Safety plan must be approved by the ___
The Fire Safety plan must be approved by the ___
Signup and view all the answers
Fire guards on office building duty must patrol the entire building at least ___
Fire guards on office building duty must patrol the entire building at least ___
Signup and view all the answers
Areas where accumulated garbage present a particular fire hazard are in
Areas where accumulated garbage present a particular fire hazard are in
Signup and view all the answers
During their rounds, the fireguard must ___ inspect all fire protection devices
During their rounds, the fireguard must ___ inspect all fire protection devices
Signup and view all the answers
Fireguards are responsible for knowing ___
Fireguards are responsible for knowing ___
Signup and view all the answers
Interior fire alarm boxes are located ___
Interior fire alarm boxes are located ___
Signup and view all the answers
The two types of fire alarm boxes are ___
The two types of fire alarm boxes are ___
Signup and view all the answers
Once activated, the fire alarm system can only be shut off at the ___ by using a special key
Once activated, the fire alarm system can only be shut off at the ___ by using a special key
Signup and view all the answers
In a fire emergency, building occupants must be ___
In a fire emergency, building occupants must be ___
Signup and view all the answers
In a fire emergency, occupants ___ are NOT immediately seriously threatened by the spread of fire
In a fire emergency, occupants ___ are NOT immediately seriously threatened by the spread of fire
Signup and view all the answers
Safety signs likely to be found around a building DON'T describe ___
Safety signs likely to be found around a building DON'T describe ___
Signup and view all the answers
Exit signs posted above doorways must be ___
Exit signs posted above doorways must be ___
Signup and view all the answers
The fireguard must wait at the exterior alarm box used in an emergency in order to ___
The fireguard must wait at the exterior alarm box used in an emergency in order to ___
Signup and view all the answers
Locks, bolts and chains may be installed on exits when ___
Locks, bolts and chains may be installed on exits when ___
Signup and view all the answers
Any leaks or breaks in the piping, tanks, valves, etc. of a sprinkler system must be ___
Any leaks or breaks in the piping, tanks, valves, etc. of a sprinkler system must be ___
Signup and view all the answers
The symbol on a fire extinguisher (A, AB, ABC, or K) indicates the ___
The symbol on a fire extinguisher (A, AB, ABC, or K) indicates the ___
Signup and view all the answers
A set of ___ extra sprinkler heads must always be kept on the premises if there is a sprinkler system
A set of ___ extra sprinkler heads must always be kept on the premises if there is a sprinkler system
Signup and view all the answers
In a standpipe system, water is sprayed onto a fire through ___
In a standpipe system, water is sprayed onto a fire through ___
Signup and view all the answers
Portable fire extinguishers must be inspected ___
Portable fire extinguishers must be inspected ___
Signup and view all the answers
A tag on a fire extinguisher marks ___
A tag on a fire extinguisher marks ___
Signup and view all the answers
Fire extinguishers are generally inspected by ___
Fire extinguishers are generally inspected by ___
Signup and view all the answers
An OS&Y valve controls ___
An OS&Y valve controls ___
Signup and view all the answers
The OS&Y (Outside Stem and Yoke) valve should be sealed in ___ position:
The OS&Y (Outside Stem and Yoke) valve should be sealed in ___ position:
Signup and view all the answers
An OS&Y is generally sealed with a ___
An OS&Y is generally sealed with a ___
Signup and view all the answers
An OS&Y valve with (a) ___ must be inspected monthly
An OS&Y valve with (a) ___ must be inspected monthly
Signup and view all the answers
An OS&Y valve with a ___ must be inspected weekly
An OS&Y valve with a ___ must be inspected weekly
Signup and view all the answers
If one can completely turn the wheel of an OS&Y valve past the fully opened or closed position, the valve is deemed ___
If one can completely turn the wheel of an OS&Y valve past the fully opened or closed position, the valve is deemed ___
Signup and view all the answers
When a part of the sprinkler system or standpipe system is shut down for repairs, the fireguard must ___
When a part of the sprinkler system or standpipe system is shut down for repairs, the fireguard must ___
Signup and view all the answers
General safeguards against fire hazards DON'T include ___
General safeguards against fire hazards DON'T include ___
Signup and view all the answers
If the alarm or sprinkler system of a building is out of service, a fireguard must be on duty ___
If the alarm or sprinkler system of a building is out of service, a fireguard must be on duty ___
Signup and view all the answers
Fire wardens and deputy fire wardens are generally ___
Fire wardens and deputy fire wardens are generally ___
Signup and view all the answers
Class A fires involve which type of combustibles?
Class A fires involve which type of combustibles?
Signup and view all the answers
What extinguishing agents can be used for Class B fires?
What extinguishing agents can be used for Class B fires?
Signup and view all the answers
Class C fires involve which of the following?
Class C fires involve which of the following?
Signup and view all the answers
Which type of fire requires a special extinguishing agent that does not react with the burning metal?
Which type of fire requires a special extinguishing agent that does not react with the burning metal?
Signup and view all the answers
What does the acronym P.A.S.S stand for in regards to using a fire extinguisher?
What does the acronym P.A.S.S stand for in regards to using a fire extinguisher?
Signup and view all the answers
Study Notes
Fireguard Regulations and Responsibilities
- Fireguards are not required at libraries.
- Fireguards should maintain composure for effective emergency management.
- Daily checks of buildings for fire hazards are mandated.
- A fireguard must patrol the entire office building at least once every hour.
Fire Alarm Systems
- All fire alarm boxes must be painted red.
- Minimum of one fire alarm box required on each floor.
- In large buildings, fire alarm boxes must not be more than 200 feet apart.
- Fire alarm boxes must be mounted between 3.5 to 5 feet above the floor.
- Active fire alarm systems can only be shut off at the main control panel using a special key.
Emergency Procedures
- Notification of the fire department can occur via telephone, radio, or external alarm box.
- Building occupants must be instructed to remain calm, not use elevators, and evacuate orderly during emergencies.
- Those located on floors below a fire are not immediately threatened by fire spread.
Fire Safety Signage
- Exit signs must be illuminated and posted above doorways.
- Safety signs do not describe building construction or fire protection features.
Fire Protection Systems
- Sprinkler heads are activated by heat and must be replaced once activated.
- Monthly inspections are required for portable fire extinguishers.
- Any leaks in sprinkler systems must be reported immediately to the local fire department.
Fire Extinguishers and Classifications
- The fire extinguisher charge can be checked by reading the gauge.
- Extinguishers are categorized (Class A, B, C, D, K) based on their suitable use:
- Class A: Ordinary combustibles (green triangle).
- Class B: Flammable liquids/gas (red square).
- Class C: Electrical fires (blue circle).
- Class D: Combustible metals (yellow five-point star).
- Class K: Kitchen fires (symbol not applicable).
Maintenance and Inspections
- Fire extinguishers must be inspected monthly, with tags indicating inspection dates.
- Sprinkler and standpipe systems require yearly inspections.
- An OS&Y valve’s main water supply should be sealed open and inspected monthly; if equipped with a valve lock-seal, inspection frequency increases to weekly.
Additional Responsibilities
- Fireguards must visually inspect all fire protection devices during their rounds.
- Six extra sprinkler heads should be kept on the premises if a sprinkler system is installed.
- If fire protection systems are out of service, a fireguard needs to be present 24/7.
Emergency Preparedness and Training
- Fire wardens and deputy fire wardens are trained volunteers from building tenants.
- Adherence to fire safety regulations and understanding basic firefighting techniques is essential for fireguards.
Fire Safety Technique
- The acronym P.A.S.S helps remember how to use a fire extinguisher:
- Pull the pin
- Aim at the base of the fire
- Squeeze the extinguisher trigger
- Sweep side to side