Ch 17 pg 439-445
34 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

You should leave the head of the pike pole up in the cockloft for about __ seconds and then bring it down for examination

15

You should advance ___ ft if you open up your first hole right at the front door and do not find fire over your head

8-10ft

For moderate size fires on ground floor of a store use ___ lines

2 1/2

When staffing permits have a third _____ size line (1 1/2, 1 3/4, or 2 in) line for following the 2 1/2, washing down areas that the first lines missed. This is not a backup line( overhaul)

<p>Medium</p> Signup and view all the answers

For heavy fires in stores, unless you have a large response of personnel, forget about a handline attack on the involved store initially and position _____ stores down ahead of the cockloft fire

<p>Several</p> Signup and view all the answers

Bring 10ft pike poles to get the ceiling of the exposed stores down rapidly for the entire depth of the store Atleast __ ft wide

<p>3</p> Signup and view all the answers

Be aware that ___ or ___ lines (1 1/2, 1 3/4, or 2) may be required in each store where you elect to make your stand

<p>Two three</p> Signup and view all the answers

The ___ body of fire may be attacked with a pre connected deck gun or some other master stream.

<p>Main</p> Signup and view all the answers

A heavy body of fire in a store can easily require _____ gpm to darken it down

<p>800-900</p> Signup and view all the answers

On page 440 it says that placing a platform in front of the show windows you can put in place a highly mobile ____ gpm plus master stream

<p>1000</p> Signup and view all the answers

If you are using a platform and are not seeing improvement fairly soon you may not be hitting the main body or there is an exceptionally heavy body of fire or from flammable liquids or ___ containers

<p>Gas</p> Signup and view all the answers

Fires that begin or enter the _____ are probably the major causes of total loss of taxpayer buildings

<p>Cockloft</p> Signup and view all the answers

Multiple _____ ceilings make exposing cockloft fires difficult

<p>Suspended</p> Signup and view all the answers

Open up at the ____ to each area to check suspended ceilings for fire. Make sure to reach the roof boards

<p>Entrance</p> Signup and view all the answers

Under cockloft fire conditions medium size lines ( ___ or more per store) are needed to permit rapid repositioning

<p>Two</p> Signup and view all the answers

It requires __ or more people per store to pull ceilings, an equal number to staff the hoselines and additional crews to preform roof ventilation and attack the main body of fire

<p>6</p> Signup and view all the answers

It might be possible for the nozzle person to stand on a ____, countertop or short ladder to direct the stream deeper into the cockloft

<p>Table</p> Signup and view all the answers

A cockloft nozzle requires a ____ in hole to be opened to allow it to operate and can direct water across the cockloft of an entire __- 100ft deep store with a single line

<p>12x12 80</p> Signup and view all the answers

You may have to use cellar pipes and distributors in ____ markets and butcher shops where you might find ceilings of plastic _____ glued over the plywood

<p>Meat laminate</p> Signup and view all the answers

The IC must be informed of nearby ___ exposures, especially those with ____ that overlook the roof

<p>Taller windows</p> Signup and view all the answers

Hand lines should be stretched to each area that ____ the fire building

<p>Overlooks</p> Signup and view all the answers

Two members operating in the tower ladder basket can rapidly apply more than ____ gpm pg 443

<p>1200</p> Signup and view all the answers

One of the key ingredients for tower ladders is to maintain as ____ a nozzle pressure as possible through a ____ tip

<p>High solid</p> Signup and view all the answers

If only 800gpm were available for a tower ladder, the usual tip would be a 1 3/4 tip at 80 psi, but using a ____ in tip at ____ psi nozzle pressure gives far greater penetration and reach

<p>1 1/2 140</p> Signup and view all the answers

On many newer strip malls, there is an all ____ overhanging soffit along the front of the row of stores

<p>Metal</p> Signup and view all the answers

A fast method for this metal soffit is to use a metal ____ saw from the basket of an elevating platform to cut away large sections of the fascia

<p>Circular</p> Signup and view all the answers

One of the most unrecognized problems with a cockloft fire in a store is the collapse of the _____ wall

<p>Parapet</p> Signup and view all the answers

Where this is show windows, the parapet wall is carried on a steel ____ across the opening

<p>I beam</p> Signup and view all the answers

Parapet wall are often given a lot of ____ reinforcement which causes it all to fall if one part goes

<p>Lateral</p> Signup and view all the answers

One of the secrets to success at taxpayer fires— knowing what is ___ to happen and having the ____ to take action to cut it off at the start

<p>Likely foresight</p> Signup and view all the answers

Roof operations demand Atleast __ members with two saws, __ hooks, two axes and two halligan tools immediately

<p>4 4</p> Signup and view all the answers

An officer experienced in roof operations should also be assigned as the roof ___ commander

<p>Sector</p> Signup and view all the answers

A serious store fire or cockloft fire demand at least __ lines almost at once, plus truck personnel to force entry, pull ceilings and so fourth

<p>3</p> Signup and view all the answers

One ___ gpm handline is often more effective than two ___ gpm lines, because of the added reach and penetration, while using the same number of personnel

<p>300 150</p> Signup and view all the answers

Flashcards

Pike Pole Time in Cockloft

The time in seconds to leave the pike pole up in the cockloft before bringing it down for examination.

Initial Advance Distance

The distance to advance if you open up the first hole at the front door and don't find fire overhead.

Hose Size for Moderate Store Fires

The ideal size of fire hoses to use for moderate size fires on the ground floor of a store.

Follow Up Line

A third line, smaller than the main lines, used to follow up and cover areas missed by the initial lines.

Signup and view all the flashcards

Heavy Store Fire Strategy

For heavy store fires, instead of attacking the main store, focus on positioning lines in adjacent stores to prevent spread.

Signup and view all the flashcards

Ceiling Pull Down Width

The width of the area to pull down ceilings in exposed stores during a cockloft fire.

Signup and view all the flashcards

Lines Needed in Exposed Stores

The number of lines needed in exposed stores during a cockloft fire.

Signup and view all the flashcards

Main Body Fire Attack

The main body of fire can be attacked with a master stream.

Signup and view all the flashcards

GPM for Heavy Store Fire

The approximate gallons per minute (gpm) needed to extinguish a heavy body of fire in a store.

Signup and view all the flashcards

Master Stream for Store Fires

The type of master stream commonly used for attacking fires in stores.

Signup and view all the flashcards

Lack of Improvement in Cockloft Fire

Possible reasons for lack of improvement in a cockloft fire even with a master stream.

Signup and view all the flashcards

Cause of Total Loss in Taxpayer Buildings

A common cause of total loss in taxpayer buildings.

Signup and view all the flashcards

Challenge of Suspended Ceilings

A challenge presented by multiple suspended ceilings when fighting cockloft fires.

Signup and view all the flashcards

Cockloft Fire Inspection Point

The location to check for fire when fighting a cockloft fire.

Signup and view all the flashcards

Lines Needed Per Store for Cockloft Fire

The number of medium lines needed per store to fight a cockloft fire.

Signup and view all the flashcards

Personnel Needed Per Store for Cockloft Fire

The number of personnel needed per store to fight a cockloft fire.

Signup and view all the flashcards

Reaching Deep into Cockloft

A possible solution for reaching deep into the cockloft with a hose.

Signup and view all the flashcards

Cockloft Nozzle Hole Size

The dimensions of the hole needed for a cockloft nozzle.

Signup and view all the flashcards

Cockloft Nozzle Reach

The distance that a cockloft nozzle can reach with a single line.

Signup and view all the flashcards

Ceilings in Meat Markets

The type of ceilings found in meat markets and some butcher shops.

Signup and view all the flashcards

Importance of Nearby Exposures

The importance of nearby exposures, especially those with windows overlooking the roof.

Signup and view all the flashcards

Hand Line Placement

The location where hand lines should be stretched during a fire.

Signup and view all the flashcards

Water Output of Tower Ladder

The amount of water that two firefighters can apply with a tower ladder.

Signup and view all the flashcards

High Nozzle Pressure in Tower Ladder

The importance of maintaining a high nozzle pressure through a solid tip when using a tower ladder.

Signup and view all the flashcards

Tower Ladder Nozzle Tip and Pressure

The size of the nozzle tip and the nozzle pressure that maximize reach and penetration with a tower ladder.

Signup and view all the flashcards

Strip Mall Soffit

The type of soffit often found on newer strip malls.

Signup and view all the flashcards

Removing Metal Soffit

A quick method for removing a metal soffit.

Signup and view all the flashcards

Hidden Collapse Risk

A potential issue with cockloft fires in stores.

Signup and view all the flashcards

Parapet Wall Support

The structural support of a parapet wall over show windows.

Signup and view all the flashcards

Parapet Collapse Factor

The factor that makes parapet walls prone to complete collapse.

Signup and view all the flashcards

Success in Taxpayer Fires

The key to success in taxpayer fires, which includes knowing what's likely to happen and taking action to stop it early.

Signup and view all the flashcards

Roof Operations Crew

The minimum number of firefighters needed for roof operations, along with the necessary equipment.

Signup and view all the flashcards

Roof Sector Commander

The role assigned to an experienced officer during roof operations.

Signup and view all the flashcards

Lines Needed for Serious Fire

The minimum number of fire lines needed during a serious store or cockloft fire.

Signup and view all the flashcards

Efficiency of Handline

Why using a single 300 gpm handline can be more efficient than two 150 gpm lines.

Signup and view all the flashcards

Firefighting Resources

The number of lines needed for store fires and cockloft fires, along with the other necessary personnel.

Signup and view all the flashcards

More Like This

SCBA Hose Folding Techniques
24 questions

SCBA Hose Folding Techniques

FancyDalmatianJasper avatar
FancyDalmatianJasper
202.16 FIRE ATTACK
5 questions

202.16 FIRE ATTACK

WellRunCanyon3722 avatar
WellRunCanyon3722