What radio designation would a firefighter working on Engine 51 use?

  • Fighter Engine 5-1 (correct)
  • Engine 5-1
  • Rescue 5-1
  • Driver Engine 5-1
  • What is the suggested maximum flow rate from onboard tank water?

  • 100 gpm
  • 150 gpm
  • 200 gpm (correct)
  • 250 gpm
  • At what percentage of tank water remaining should the Driver Operator advise command and crews of low water levels?

  • 75%
  • 25%
  • 50% (correct)
  • 10%
  • What is the water capacity of a Tender?

    <p>3,000 gallons (A)</p> Signup and view all the answers

    What is the Emergency Evacuation procedure once it has been announced?

    <p>Sound radio alert tones and advise all companies to evacuate. (B)</p> Signup and view all the answers

    What is the recommended minimum fill rate for a tender during shuttle operations?

    <p>1000 GPM (D)</p> Signup and view all the answers

    Which of the following is a consideration for placing a gate valve?

    <p>On each fill line (B)</p> Signup and view all the answers

    What is the average fire flow required for a typical single family dwelling?

    <p>250-500 GPM (A)</p> Signup and view all the answers

    How many high volume pumps are recommended for use in float a pump operations?

    <p>Two (D)</p> Signup and view all the answers

    What is the maximum time the first tender must begin dumping water to ensure optimal ISO ratings?

    <p>5 minutes (D)</p> Signup and view all the answers

    In a water shuttle operation, what route is considered optimal for travel?

    <p>Circular route (A)</p> Signup and view all the answers

    What should be done prior to placing pumps and equipment back in service?

    <p>Back flush the pumps (C)</p> Signup and view all the answers

    When should a second tender be requested during a working fire in rural areas?

    <p>During initial response (B)</p> Signup and view all the answers

    What is the main advantage of placing the largest capacity pump at the source?

    <p>It ensures sufficient pressure for longer distances. (A)</p> Signup and view all the answers

    When is a relay pump established if the attack engine is more than 500 feet from a hydrant?

    <p>When the attack engine is using a 5&quot; supply line. (B)</p> Signup and view all the answers

    What is the minimum residual pressure each engine must maintain on their intake gauge during a relay operation?

    <p>20 psi (C)</p> Signup and view all the answers

    What action should be taken first when beginning relay pumping operations?

    <p>Ensure all apparatus are in place and hose connections are made. (A)</p> Signup and view all the answers

    During nurse tender operations, what should the attack engine do to ensure a continuous water supply?

    <p>Keep its onboard water tank full at all times. (A)</p> Signup and view all the answers

    What does the PDP formula represent in relay pumping?

    <p>Pump discharge pressure needed for flow. (C)</p> Signup and view all the answers

    What is the role of the Water Supply Officer during shuttle operations?

    <p>To communicate directly with the Incident Commander. (B)</p> Signup and view all the answers

    What is the purpose of using a Siamese appliance in direct pumping operations?

    <p>To connect multiple supply lines to a single engine. (B)</p> Signup and view all the answers

    Why does the second arriving unit in direct pumping operations pump at half the pressure of the first?

    <p>To keep the water static until needed. (D)</p> Signup and view all the answers

    What factor is NOT considered prior to establishing relay pumping operations?

    <p>Common types of pumps used. (C)</p> Signup and view all the answers

    What should all personnel do immediately during an emergency traffic situation?

    <p>Evacuate the area (A)</p> Signup and view all the answers

    What information is primarily obtained by the Incident Commander (IC) from the communications center?

    <p>Water supply and fire flow information (C)</p> Signup and view all the answers

    Which symbol indicates an operational hydrant in the system?

    <p>Green hydrant (D)</p> Signup and view all the answers

    How often must each battalion submit hydrant water usage reports?

    <p>Monthly (B)</p> Signup and view all the answers

    What color signifies a dry hydrant that has failed its annual test?

    <p>Red (A)</p> Signup and view all the answers

    What is the maximum speed at which a 5" supply line can be driven when connecting to a hydrant?

    <p>15 mph (B)</p> Signup and view all the answers

    Dry hydrants are primarily used in areas where:

    <p>Pressurized water systems are unavailable (C)</p> Signup and view all the answers

    What is the purpose of performing a Personal Accountability Report (PAR)?

    <p>To ensure all personnel are accounted for (B)</p> Signup and view all the answers

    What type of hydrant is identified by a stainless steel 'lock barrel'?

    <p>Captivater hydrants (B)</p> Signup and view all the answers

    What is a key requirement when laying supply lines from a hydrant?

    <p>Drive no faster than 15 mph (D)</p> Signup and view all the answers

    What does the purple/pink color denote on reclaimed water flushing hydrants?

    <p>They are operational only for irrigation (B)</p> Signup and view all the answers

    What is required before attempting to draft water from a static source?

    <p>Ensure surrounding conditions are clear (D)</p> Signup and view all the answers

    Which method best supplies a continuous water operation for firefighting?

    <p>Relay Pumping (A)</p> Signup and view all the answers

    What is the preferred method of water supply in rural areas for initial fire attack, especially during the first due response to confirmed structure fires?

    <p>Modified Direct Pumping (B)</p> Signup and view all the answers

    During Modified Direct Pumping operations, how is the total of 6,000 gallons of water supply acquired?

    <p>2 Engines, 2 Brush Trucks, and 1 Tender (C)</p> Signup and view all the answers

    What is the recommended placement of brush trucks during Modified Direct Pumping operations?

    <p>Close to the attack engine, but out of the way of other apparatus (D)</p> Signup and view all the answers

    Which of the following is NOT a key consideration in determining the success of Folding/Dump Tank operations?

    <p>Availability of multiple pumpers on scene (D)</p> Signup and view all the answers

    What is the minimum average flow rate required for tenders to dump their tanks, according to NFPA 1901?

    <p>1000 gpm (D)</p> Signup and view all the answers

    During Folding/Dump Tank operations, how many hard suction sections are recommended and why?

    <p>Two hard suction sections for decreased tension and ease of placement (C)</p> Signup and view all the answers

    What is the recommended flow rate from the source engine during Folding/Dump Tank operations to maintain prime?

    <p>A low flow rate, just enough to maintain prime (A)</p> Signup and view all the answers

    When is the most appropriate time to transition from Modified Direct Pumping operations to Relay Pumping?

    <p>As soon as possible if the incident is anticipated to last for an extended period of time (C)</p> Signup and view all the answers

    What is the primary purpose of the Fill Site during Folding/Dump Tank operations?

    <p>To reload the apparatus as quickly as possible for a full tank of water (A)</p> Signup and view all the answers

    What is the minimum pump capacity required for the source apparatus when using a static source as a Fill Site during Folding/Dump Tank operations?

    <p>1250 gpm (C)</p> Signup and view all the answers

    What is the primary limitation of Folding/Dump Tank operations, making it less ideal for some situations?

    <p>Excessive time consumption and need for manpower (D)</p> Signup and view all the answers

    What is the recommended size and location of the Folding/Dump Tank during operations?

    <p>Medium-sized, placed on level ground, easy to access (D)</p> Signup and view all the answers

    What is the major concern when considering the location of a dump site for Folding/Dump Tank operations?

    <p>Easy access and egress for apparatus and personnel (D)</p> Signup and view all the answers

    Which of the following is a common misconception regarding the use of a Folding/Dump Tank?

    <p>They require minimal manpower and can be set up quickly (A)</p> Signup and view all the answers

    What is the recommended approach to supply the attack engine during Folding/Dump Tank operations?

    <p>Use a supply engine with a 5” line to establish a draft from the tank (A)</p> Signup and view all the answers

    What is the minimum residual pressure that each engine must maintain on its intake gauge during a relay operation?

    <p>20 psi (B)</p> Signup and view all the answers

    When should a relay be established if the attack engine is more than 500 feet from a hydrant?

    <p>When using a 5-inch supply line. (C)</p> Signup and view all the answers

    What is the recommended action to take first when beginning relay pumping operations?

    <p>Ensure all engines are in place and hose connections are made. (B)</p> Signup and view all the answers

    What does the PDP formula represent in relay pumping operations?

    <p>The pressure needed to maintain at least 20 psi residual pressure at the attack engine. (A)</p> Signup and view all the answers

    What is the role of the Water Supply Officer (WSO) during water shuttle operations?

    <p>To communicate with the Incident Commander about water supply availability. (A)</p> Signup and view all the answers

    What is the minimum fill rate recommended for a water tender during shuttle operations?

    <p>1000 GPM (C)</p> Signup and view all the answers

    When placing cones at a fill site, what is the recommended placement in relation to the driver's door?

    <p>The cone should be placed to the right of the driver's door. (C)</p> Signup and view all the answers

    What is the recommended method of supplying water to the attack engine during a water shuttle operation when the first tender arrives at the scene?

    <p>Direct pumping from the tender (B)</p> Signup and view all the answers

    What is the primary purpose of a Make and Break person during a water shuttle operation?

    <p>Connecting and disconnecting hoses to and from the water tenders (A)</p> Signup and view all the answers

    When using a float a pump, where should the source pumper be placed in relation to the pump?

    <p>As close as possible to the pump to reduce friction loss (A)</p> Signup and view all the answers

    What action should the Driver Operator take when the onboard water tank reaches 25% capacity?

    <p>Advise command and crews of the low water level (C)</p> Signup and view all the answers

    How long will it take to deplete a standard 750-gallon water tank when flowing at 150 gpm?

    <p>Approximately 5 minutes (D)</p> Signup and view all the answers

    What is the recommended maximum flow rate from the onboard tank water?

    <p>200 gpm (B)</p> Signup and view all the answers

    What is the water capacity of a standard Rescue Pumper?

    <p>300 gallons (B)</p> Signup and view all the answers

    What is the purpose of using radio alert tones during an emergency evacuation?

    <p>To alert all personnel on the scene of the imminent danger and the need to evacuate (B)</p> Signup and view all the answers

    At what percentage of remaining tank water does an Emergency Evacuation procedure take place?

    <p>25% (C)</p> Signup and view all the answers

    Which of the following is NOT a water delivery method mentioned in the content?

    <p>Tanker Operations (A)</p> Signup and view all the answers

    How often should the Driver Operator advise command and crews when the tank levels drop?

    <p>When the tank reaches 50% and again at 25% (D)</p> Signup and view all the answers

    What is the recommended speed limit when laying 5" supply lines to and from a hydrant to prevent accidental dropping on the tailboard?

    <p>10-15 mph (C)</p> Signup and view all the answers

    What are the three factors relating to hydrants that may influence fire department operations during a fire incident?

    <p>Location, operation, and flow (B)</p> Signup and view all the answers

    What is the minimum capacity of a water tank required by county code for construction sites that do not have fire hydrants yet installed?

    <p>20,000 gallons (B)</p> Signup and view all the answers

    Which of these is NOT a type of water source commonly found in Palm Beach County?

    <p>Natural Gas Lines (B)</p> Signup and view all the answers

    What is the common thread size found on water tank/cisterns that are used as fire department water supply?

    <p>4.5&quot; NST Male (D)</p> Signup and view all the answers

    What is the main characteristic that distinguishes Reclaimed Water Flushing hydrants from other hydrants?

    <p>They are highly chlorinated and only for irrigation purposes. (B)</p> Signup and view all the answers

    What is the color code used in the Water Source Locator software to identify a reliable drafting site?

    <p>Blue (C)</p> Signup and view all the answers

    What is the significance of a green tag on a dry hydrant?

    <p>The hydrant has passed its annual test and is operational. (C)</p> Signup and view all the answers

    Who is responsible for notifying the water utility company of the need to boost hydrant pressure during an incident?

    <p>The Communications Center (A)</p> Signup and view all the answers

    Which of the following is considered the best option for water operations, if given the option?

    <p>Relay Pumping (D)</p> Signup and view all the answers

    What is the primary benefit of utilizing Modified Direct Pumping in rural areas with limited water supply?

    <p>It can yield a significant water supply for initial fire attack, potentially reaching up to 6,000 gallons. (B)</p> Signup and view all the answers

    During Modified Direct Pumping operations, which units should be positioned close to the attack engine but out of the way of other apparatus?

    <p>Brush Trucks (B)</p> Signup and view all the answers

    When is it recommended to transition from Modified Direct Pumping operations to Relay Pumping?

    <p>As soon as possible if the incident is anticipated to last for an extended period of time. (D)</p> Signup and view all the answers

    According to NFPA 1901, what is the minimum average flow rate required for tenders to dump their tanks?

    <p>1,000 gpm (D)</p> Signup and view all the answers

    During Folding/Dump Tank operations, why are two hard suction sections recommended?

    <p>To reduce tension on the suction hose and facilitate easy placement in the lowest part of the tank. (C)</p> Signup and view all the answers

    Which of the following is a major limitation of Folding/Dump Tank operations, making it less ideal for some situations?

    <p>All of the above. (D)</p> Signup and view all the answers

    What is the primary concern when considering the location of a dump site for Folding/Dump Tank operations?

    <p>All of the above. (D)</p> Signup and view all the answers

    Flashcards

    Water Supply Methods

    Various techniques to deliver water for fireground operations, including hydrants and tank supplies.

    Driver Operator Radio Designation

    Radio designation for a driver operator on E51 is Driver Engine 5-1.

    Water Capacity of Engines

    Engines typically have a water capacity of 750 or 1000 gallons.

    Emergency Evacuation Definition

    Used to notify of imminent danger, requiring personnel to evacuate to a safe place.

    Signup and view all the flashcards

    Tank Water Depletion Notification

    The driver operator must notify when onboard tank levels drop to 50% and 25% full.

    Signup and view all the flashcards

    Source Engine

    The engine located at the water source providing supply.

    Signup and view all the flashcards

    Attack Engine

    The engine located at the scene attacking the fire.

    Signup and view all the flashcards

    Relay Pumpers

    Any apparatus placed between the source and attack engines.

    Signup and view all the flashcards

    Friction Loss

    Pressure loss due to resistance in hoses during water flow.

    Signup and view all the flashcards

    Pump Discharge Pressure (PDP)

    Calculated by adding friction loss and 20 psi for the engine being supplied.

    Signup and view all the flashcards

    Water Supply Officer (WSO)

    Person in charge of managing water supply during operations.

    Signup and view all the flashcards

    Nurse Tender Operations

    Involves a tender relaying water to an attack engine.

    Signup and view all the flashcards

    Direct Pumping

    Combination of nurse tender and relay pumping using a single supply line.

    Signup and view all the flashcards

    Water Shuttle Operations

    Process where vehicles deliver water back and forth to the scene.

    Signup and view all the flashcards

    Static Water Source

    A non-flowing water source, such as a pond or lake, used by fire engines.

    Signup and view all the flashcards

    Emergency Traffic Procedure

    Units use air horns to signal emergency conditions, alternating silence for 50 seconds.

    Signup and view all the flashcards

    Personnel Accountability Report (PAR)

    A report performed by the Incident Commander to ensure all personnel are accounted for.

    Signup and view all the flashcards

    National Standard Thread (NST)

    A standard for hydrant threading, also known as NHT.

    Signup and view all the flashcards

    Operational Hydrant Symbol

    Green hydrant symbol indicates that it is operational.

    Signup and view all the flashcards

    Non-Operational Hydrant Symbol

    Red hydrant symbol signifies that it is non-operational.

    Signup and view all the flashcards

    Dry Hydrants

    Non-pressurized hydrants used for drafting water from static sources.

    Signup and view all the flashcards

    Drafting Process

    Raising water from a static source into a fire pump.

    Signup and view all the flashcards

    Relay Pumping

    Continuous water supply method involving multiple apparatuses moving water.

    Signup and view all the flashcards

    Water Source Locator Software

    Provides data on hydrant locations, pressure, and flow.

    Signup and view all the flashcards

    Monthly Hydrant Water Usage Log

    Records water used for various operations, submitted monthly.

    Signup and view all the flashcards

    Communications Center Role

    Notifies water utility company about pressure needs during incidents.

    Signup and view all the flashcards

    Cistern Requirements

    Contractors must provide a 20,000-gallon tank during construction site inspections.

    Signup and view all the flashcards

    Hydrant Documentation

    Hydrants in disrepair must be reported to the FOO and Water Officer.

    Signup and view all the flashcards

    Check Valve Function

    A valve in dry hydrants preventing back-flush, marked as 'CV-No Back-Flush'.

    Signup and view all the flashcards

    Modified Direct Pumping

    A method where the attack engine is supplied by multiple units simultaneously through multiple lines.

    Signup and view all the flashcards

    Direct Pumping Limits

    Limits the water supply to attack engine to 500 gpm due to hose velocity.

    Signup and view all the flashcards

    6000 Gallons Water Supply

    Achieved by utilizing 2 engines, 2 brush trucks, and 1 tender during modified direct pumping.

    Signup and view all the flashcards

    Folding/Dump Tank Operations

    Process where water is delivered to a portable tank on the scene instead of direct supply.

    Signup and view all the flashcards

    Dump Site Considerations

    Includes one or more portable dump tanks located near the scene for quick access.

    Signup and view all the flashcards

    Fill Site Purpose

    Reloads apparatus quickly so they can return to the fire scene with water.

    Signup and view all the flashcards

    Limitations of Folding/Dump Tanks

    Time-consuming, requires large area, and cannot supply aerials or master streams.

    Signup and view all the flashcards

    Transition to Relay Pumping

    Shift to relay pumping as soon as it’s feasible during an extended incident.

    Signup and view all the flashcards

    Location of Fill Site

    Ideal fill site located at hydrants or static sources for quick water access.

    Signup and view all the flashcards

    Drafting from Dump Tank

    Attack engine may draft from the dump tank but best to have supply engine established.

    Signup and view all the flashcards

    Positioning Tenders

    Tenders should be placed clear of other apparatus for efficient access and egress.

    Signup and view all the flashcards

    Low Level Strainer

    Used to draft water from a dump tank, effective up to 2 inches of water.

    Signup and view all the flashcards

    Time to Dump Tank

    Tenders can dump their full tank in about 3-4 minutes during operations.

    Signup and view all the flashcards

    Booster Line Purpose

    The source engine should flow a small discharge into the tank to maintain pump prime.

    Signup and view all the flashcards

    Spotter Role

    Responsible for monitoring conditions and directing tender dump placement during operations.

    Signup and view all the flashcards

    Optimal Draft Site

    Site selected to maximize available water supply with minimal lift.

    Signup and view all the flashcards

    Back Flush Pumps

    Process of clearing debris from pumps and equipment before service.

    Signup and view all the flashcards

    Cone Positioning

    Use cones at fill sites to guide drivers on positioning.

    Signup and view all the flashcards

    Tender Filling Rate

    Recommended minimum fill rate for a tender is 1000 GPM.

    Signup and view all the flashcards

    Tender Apparatus

    Apparatus designed to carry 3000 gallons of water for firefighting.

    Signup and view all the flashcards

    Water Shuttle Route

    Circular route is optimal for water shuttle operations.

    Signup and view all the flashcards

    Float Pump Limitations

    Float pumps are last resort options and have varied capacities.

    Signup and view all the flashcards

    Iso Rating Requirement

    First tender must dump water within 5 minutes for optimal ISO ratings.

    Signup and view all the flashcards

    Water Tank Depletion Time

    Flowing 150gpm from a 750-gallon tank takes about 5 minutes to deplete.

    Signup and view all the flashcards

    Emergency Evacuation Water Level

    Emergency evacuation is performed when water level drops to 25% full.

    Signup and view all the flashcards

    Tank Level Notifications

    Driver operator must notify when tank is 50% and 25% full.

    Signup and view all the flashcards

    Tender Water Capacity

    Tender apparatus typically carries 3,000 gallons of water.

    Signup and view all the flashcards

    Aerial Water Capacity

    Aerial apparatus has a water capacity of 500 gallons.

    Signup and view all the flashcards

    Brush Truck Water Capacity

    Brush trucks can hold either 500 or 750 gallons of water.

    Signup and view all the flashcards

    Direct Pumping Limitation

    Do not supply more than 200gpm unless connected to a secure source.

    Signup and view all the flashcards

    Communication During Evacuation

    When evacuation is announced, radio alert tones are sounded to notify all crews.

    Signup and view all the flashcards

    Long Narrow Driveways

    Supply lines should originate from the street to the fire for access.

    Signup and view all the flashcards

    Tender Dump Time

    Tenders can unload their water tank within 3-4 minutes.

    Signup and view all the flashcards

    Limitations of Folding/Dump Operations

    They are time-consuming, require space, and cannot support aerials or master streams.

    Signup and view all the flashcards

    PDP (Pump Discharge Pressure)

    Calculated by adding friction loss and 20 psi for the engine being supplied.

    Signup and view all the flashcards

    Relay Requirements

    If an attack engine is >500 ft from hydrant, a relay must be established.

    Signup and view all the flashcards

    Take Care of Float Pumps

    Float pumps are last resort options and have varied capacities.

    Signup and view all the flashcards

    Hydrant Data Information

    Details about hydrant location, pressure, and expected flow provided via software.

    Signup and view all the flashcards

    Pre-determined Water Main Size

    Water main size often not known unless established in a Quick Access Survey.

    Signup and view all the flashcards

    Notification of OOS Hydrants

    When hydrants are out of service, FOO and Water Officer are notified.

    Signup and view all the flashcards

    Dry Hydrant Functionality

    Dry hydrants are non-pressurized, used for water drafting from static sources.

    Signup and view all the flashcards

    Monthly Hydrant Usage Submission

    Each battalion submits hydrant water usage to the Water Officer monthly.

    Signup and view all the flashcards

    Static Water Sources Examples

    Non-flowing sources like ponds, lakes, and pools that can support drafting.

    Signup and view all the flashcards

    Relay Pumping Method

    Involves pumping water through hoses from one apparatus to another for continuous supply.

    Signup and view all the flashcards

    Cistern Water Supply Requirements

    Contractors must provide tanks holding a minimum of 20,000 gallons near construction sites.

    Signup and view all the flashcards

    Emergency Evacuation Protocol

    All personnel shall immediately evacuate and report to a designated location.

    Signup and view all the flashcards

    Study Notes

    Water Delivery Methods for Fireground Operations

    • Tank Supply: Utilizing onboard water tanks for initial fire attack.
    • Hydrant: Connecting to a pressurized water source.
    • Static Water Source: Drawing water from natural bodies of water (oceans, canals, lakes, ponds, swimming pools).
    • Water Tank/Cisterns: Utilizing gravity-fed tanks for water supply; contractor-provided tanks minimum 20,000 gallons with signage and within 400 feet of the structure.
    • Relay Pumping: Pumping water through a hose to multiple fire apparatus.
      • "Source" engine at water source.
      • "Attack" engine at fire scene.
      • "Relay" pumpers between source and attack.
      • Establish relay if attack engine is over 500 feet from hydrant (3" supply line, 300 feet).
      • Prioritize largest capacity pump at source.
      • PDP = Friction Loss + 20 psi (residual pressure).
      • Start at 50 psi, adjust after PDP.
      • Intake pressure maintains at least 20 psi.
      • Consider water volume and distance.
      • Driver monitors ground conditions around parked engines.
      • Source engine, RPM mode; other units, PSI mode when using governor.
      • Goal: Similar RPM for all engines in relay.
    • Water Shuttle Operations: Transporting water from a fill site to the fire scene; used when water source is remote and relay impractical.
      • Participants: Tenders, engines, or brush trucks.
      • WSO may appoint Dump Site and/or Fill Site supervisors; communicates with IC.
      • Three Primary Rural Types: Nurse Tender, Modified Direct Pumping, Folding/Dump tank operations.
    • Nurse Tender: Tender positioned adjacent to the attack engine for rapid water supply.
      • 5" line from tender to attack engine.
      • Rapid water delivery often controls fire before refill is needed.
      • Recommended for short duration fires (rooms, garages, sheds).
      • Transition to relay if incident prolonged.
      • Attack engine keeps onboard tank full.
    • Direct Pumping: Two apparatus supplying a single attack engine via a Siamese appliance.
      • Attack Engine lays supply line.
      • Next unit connects Siamese and pumps at half pressure.
      • Water remains static due to higher pressure on Siamese from first apparatus.
      • Second unit takes over as first runs out of water.
      • Limits water supply to 500 gpm due to 3" hose critical velocity.
    • Modified Direct Pumping: Multiple supply apparatus simultaneously supplying a single attack engine through multiple lines.
      • Recommended for first due on confirmed structure fires in rural areas with limited water.
      • All units on scene as supply pumpers.
      • 6,000 gallons immediately (2 engines, 2 brush trucks, 1 tender).
      • Brush trucks close to attack engine, tenders clear for access/egress.
      • Transition to relay ASAP if incident prolonged.
    • Folding/Dump Tank Operations: Utilizing portable tanks; not the first choice in rural areas.
      • Dump Site (tank placement), Fill Site (reloading).
      • First arriving tender connects to attack engine, supplies water.
      • Multiple units directed by spotter for optimal dumping.
      • Tenders dump full tanks in ~3-4 minutes.
      • NFPA 1901: Tenders dump at a minimum 1000 gpm for 90% of tank.
      • Optional: Supply engine at folding/dump tank for draft and relay.
        • Low level strainer for drafting, ~2 inches.

    Radio Designations (E51)

    • Driver: Driver Engine 5-1
    • Firefighter: Fighter Engine 5-1
    • Officer: Engine 5-1

    Apparatus Water Capacities

    • Engines: 750 or 1000 gallons
    • Aerials: 500 gallons
    • Brush Trucks: 500 or 750 gallons
    • Tenders: 3,000 gallons
    • 600 Series Brush Trucks: 300 gallons
    • Rescue Pumpers: 300 gallons

    Tank Water Depletion

    • Driver Operator Notification: Advise command when tank levels reach 50% and 25% full.
    • Flow Rate (750 Gallons): 150 gpm depletes in ~5 minutes.
    • Maximum Flow Rate Recommendation: 200 gpm maximum unless connected to secure source.
    • Emergency Evacuation Threshold: 25% water remaining.
      • Radio alert tones sound; evacuate to rally point.
      • Emergency traffic procedures in effect; air horns.
      • Personnel report to supervisor or designated area.
      • IC performs Personnel Accountability Review (PAR).
      • SOG 220-01 for Personnel Accountability.
      • Mechanical problems: Notify IC, emergency evacuation if necessary.

    Hydrant Information

    • Threading: National Standard Thread (NST/NHT)
    • Openings: 2 - 2.5" side ports, 1 - 4.5" steamer opening.
    • Hydrant Data Source: Water Source Locator software; locations, static pressure, flow, drafting sites, dry hydrants.
    • Hydrant Status Indicator: Green = Operational, Red = Non-Operational.
    • Hydrant Factors on Operations: Location, operation, and flow.
    • Unknown Information in Quick Access Survey: Size of water main.
    • Hydrant Information Request: Communications Center or water department.
    • Water Utility Contact: IC directs Communications Center.
    • Battalion Water Usage: Monthly hydrant water usage submitted to Water Officer, documented in FR-B-103 (Monthly Hydrant Water Usage Log) includes refills, truck checks, training, and emergencies.
    • Dry Hydrants: Tested and tagged annually (PBC Fire code).
      • Tag colors: Green = Operational, Red = Non-functional.
      • Check valve location: Between steamer port and source; marked "CV-No Back-Flush".
      • Back-flushing: Required for dry hydrants without check valves.
      • Suction size: 6" NST or 4.5" NST (with possible adapters).
      • Color on Water Source Locator: Orange hydrant.
      • 5" supply lines: Driving speed 10-15 mph, do not exceed 15 mph.
    • Reclaimed Water Flushing Hydrants: Purple/pink color, highly chlorinated for irrigation only (not secure water source), last resort.

    Fill Site Considerations

    • Location: Optimal location at hydrant, considering distance/flow.
      • For static sources, minimum pump capacity 1250 gpm.
    • Equipment: 5" lines at hydrant; 1250+ gpm for static source filling.
    • Cones: Driver visibility in fill/dump.
    • Make/Break: Responsible for connections.

    General Recommendations for Water Supply Operations

    • Pre-Incident Planning: Crucial in non-hydrant areas.
    • Deployment Decisions: Informed decisions based on incident information.
    • Supply Engine Use: If possible, establish draft and relay water.

    Rural Fire Considerations

    • Minimum Water Considerations: Typical residence size requires 2,000-10,000 gallons for water.
    • Average Fire Flow: 250-500 gpm.
    • Lot Size: 1.25-acre lot is approximately 200 feet wide.
    • Minimum Deployment: Request a secondary tender in rural responses.
    • Water Volume/Deployment Capacity Calculations: IC or WSO uses formula.
    • Initial Tender Responsiveness: Within 5 minutes of arrival, begin dumping water, minimum 250 gpm for 2 hours.
    • Float a Pump: Last resort where drafting sites are inaccessible.

    Water Tank/Cisterns Operation

    • Supply Method: Gravity-fed, operational during water shuttles.
    • Drafting: Remedy is to pull a draft. Ensure vent openings are open.
    • Common Thread Sizes: 4 ½ NST male threads/ 6" - 4 ½" adapter.

    Tender Apparatus considerations

    • Carries 3000 gallons
    • Carry extra foam and SCBA on scene

    Dump Site considerations

    • Level, unobstructed ground is ideal.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on key firefighting protocols, including equipment specifications and emergency procedures. This quiz covers radio designations, water flow rates, and evacuation protocols crucial for firefighter effectiveness and safety.

    More Like This

    Engine Ops | Experience
    34 questions

    Engine Ops | Experience

    ProtectiveDaffodil avatar
    ProtectiveDaffodil
    GOG 10-12 Emergency Notification of Injury
    34 questions
    Operations Personnel Protocols
    7 questions
    Use Quizgecko on...
    Browser
    Browser