Podcast
Questions and Answers
What radio designation would a firefighter working on Engine 51 use?
What radio designation would a firefighter working on Engine 51 use?
What is the suggested maximum flow rate from onboard tank water?
What is the suggested maximum flow rate from onboard tank water?
At what percentage of tank water remaining should the Driver Operator advise command and crews of low water levels?
At what percentage of tank water remaining should the Driver Operator advise command and crews of low water levels?
What is the water capacity of a Tender?
What is the water capacity of a Tender?
Signup and view all the answers
What is the Emergency Evacuation procedure once it has been announced?
What is the Emergency Evacuation procedure once it has been announced?
Signup and view all the answers
What is the recommended minimum fill rate for a tender during shuttle operations?
What is the recommended minimum fill rate for a tender during shuttle operations?
Signup and view all the answers
Which of the following is a consideration for placing a gate valve?
Which of the following is a consideration for placing a gate valve?
Signup and view all the answers
What is the average fire flow required for a typical single family dwelling?
What is the average fire flow required for a typical single family dwelling?
Signup and view all the answers
How many high volume pumps are recommended for use in float a pump operations?
How many high volume pumps are recommended for use in float a pump operations?
Signup and view all the answers
What is the maximum time the first tender must begin dumping water to ensure optimal ISO ratings?
What is the maximum time the first tender must begin dumping water to ensure optimal ISO ratings?
Signup and view all the answers
In a water shuttle operation, what route is considered optimal for travel?
In a water shuttle operation, what route is considered optimal for travel?
Signup and view all the answers
What should be done prior to placing pumps and equipment back in service?
What should be done prior to placing pumps and equipment back in service?
Signup and view all the answers
When should a second tender be requested during a working fire in rural areas?
When should a second tender be requested during a working fire in rural areas?
Signup and view all the answers
What is the main advantage of placing the largest capacity pump at the source?
What is the main advantage of placing the largest capacity pump at the source?
Signup and view all the answers
When is a relay pump established if the attack engine is more than 500 feet from a hydrant?
When is a relay pump established if the attack engine is more than 500 feet from a hydrant?
Signup and view all the answers
What is the minimum residual pressure each engine must maintain on their intake gauge during a relay operation?
What is the minimum residual pressure each engine must maintain on their intake gauge during a relay operation?
Signup and view all the answers
What action should be taken first when beginning relay pumping operations?
What action should be taken first when beginning relay pumping operations?
Signup and view all the answers
During nurse tender operations, what should the attack engine do to ensure a continuous water supply?
During nurse tender operations, what should the attack engine do to ensure a continuous water supply?
Signup and view all the answers
What does the PDP formula represent in relay pumping?
What does the PDP formula represent in relay pumping?
Signup and view all the answers
What is the role of the Water Supply Officer during shuttle operations?
What is the role of the Water Supply Officer during shuttle operations?
Signup and view all the answers
What is the purpose of using a Siamese appliance in direct pumping operations?
What is the purpose of using a Siamese appliance in direct pumping operations?
Signup and view all the answers
Why does the second arriving unit in direct pumping operations pump at half the pressure of the first?
Why does the second arriving unit in direct pumping operations pump at half the pressure of the first?
Signup and view all the answers
What factor is NOT considered prior to establishing relay pumping operations?
What factor is NOT considered prior to establishing relay pumping operations?
Signup and view all the answers
What should all personnel do immediately during an emergency traffic situation?
What should all personnel do immediately during an emergency traffic situation?
Signup and view all the answers
What information is primarily obtained by the Incident Commander (IC) from the communications center?
What information is primarily obtained by the Incident Commander (IC) from the communications center?
Signup and view all the answers
Which symbol indicates an operational hydrant in the system?
Which symbol indicates an operational hydrant in the system?
Signup and view all the answers
How often must each battalion submit hydrant water usage reports?
How often must each battalion submit hydrant water usage reports?
Signup and view all the answers
What color signifies a dry hydrant that has failed its annual test?
What color signifies a dry hydrant that has failed its annual test?
Signup and view all the answers
What is the maximum speed at which a 5" supply line can be driven when connecting to a hydrant?
What is the maximum speed at which a 5" supply line can be driven when connecting to a hydrant?
Signup and view all the answers
Dry hydrants are primarily used in areas where:
Dry hydrants are primarily used in areas where:
Signup and view all the answers
What is the purpose of performing a Personal Accountability Report (PAR)?
What is the purpose of performing a Personal Accountability Report (PAR)?
Signup and view all the answers
What type of hydrant is identified by a stainless steel 'lock barrel'?
What type of hydrant is identified by a stainless steel 'lock barrel'?
Signup and view all the answers
What is a key requirement when laying supply lines from a hydrant?
What is a key requirement when laying supply lines from a hydrant?
Signup and view all the answers
What does the purple/pink color denote on reclaimed water flushing hydrants?
What does the purple/pink color denote on reclaimed water flushing hydrants?
Signup and view all the answers
What is required before attempting to draft water from a static source?
What is required before attempting to draft water from a static source?
Signup and view all the answers
Which method best supplies a continuous water operation for firefighting?
Which method best supplies a continuous water operation for firefighting?
Signup and view all the answers
What is the preferred method of water supply in rural areas for initial fire attack, especially during the first due response to confirmed structure fires?
What is the preferred method of water supply in rural areas for initial fire attack, especially during the first due response to confirmed structure fires?
Signup and view all the answers
During Modified Direct Pumping operations, how is the total of 6,000 gallons of water supply acquired?
During Modified Direct Pumping operations, how is the total of 6,000 gallons of water supply acquired?
Signup and view all the answers
What is the recommended placement of brush trucks during Modified Direct Pumping operations?
What is the recommended placement of brush trucks during Modified Direct Pumping operations?
Signup and view all the answers
Which of the following is NOT a key consideration in determining the success of Folding/Dump Tank operations?
Which of the following is NOT a key consideration in determining the success of Folding/Dump Tank operations?
Signup and view all the answers
What is the minimum average flow rate required for tenders to dump their tanks, according to NFPA 1901?
What is the minimum average flow rate required for tenders to dump their tanks, according to NFPA 1901?
Signup and view all the answers
During Folding/Dump Tank operations, how many hard suction sections are recommended and why?
During Folding/Dump Tank operations, how many hard suction sections are recommended and why?
Signup and view all the answers
What is the recommended flow rate from the source engine during Folding/Dump Tank operations to maintain prime?
What is the recommended flow rate from the source engine during Folding/Dump Tank operations to maintain prime?
Signup and view all the answers
When is the most appropriate time to transition from Modified Direct Pumping operations to Relay Pumping?
When is the most appropriate time to transition from Modified Direct Pumping operations to Relay Pumping?
Signup and view all the answers
What is the primary purpose of the Fill Site during Folding/Dump Tank operations?
What is the primary purpose of the Fill Site during Folding/Dump Tank operations?
Signup and view all the answers
What is the minimum pump capacity required for the source apparatus when using a static source as a Fill Site during Folding/Dump Tank operations?
What is the minimum pump capacity required for the source apparatus when using a static source as a Fill Site during Folding/Dump Tank operations?
Signup and view all the answers
What is the primary limitation of Folding/Dump Tank operations, making it less ideal for some situations?
What is the primary limitation of Folding/Dump Tank operations, making it less ideal for some situations?
Signup and view all the answers
What is the recommended size and location of the Folding/Dump Tank during operations?
What is the recommended size and location of the Folding/Dump Tank during operations?
Signup and view all the answers
What is the major concern when considering the location of a dump site for Folding/Dump Tank operations?
What is the major concern when considering the location of a dump site for Folding/Dump Tank operations?
Signup and view all the answers
Which of the following is a common misconception regarding the use of a Folding/Dump Tank?
Which of the following is a common misconception regarding the use of a Folding/Dump Tank?
Signup and view all the answers
What is the recommended approach to supply the attack engine during Folding/Dump Tank operations?
What is the recommended approach to supply the attack engine during Folding/Dump Tank operations?
Signup and view all the answers
What is the minimum residual pressure that each engine must maintain on its intake gauge during a relay operation?
What is the minimum residual pressure that each engine must maintain on its intake gauge during a relay operation?
Signup and view all the answers
When should a relay be established if the attack engine is more than 500 feet from a hydrant?
When should a relay be established if the attack engine is more than 500 feet from a hydrant?
Signup and view all the answers
What is the recommended action to take first when beginning relay pumping operations?
What is the recommended action to take first when beginning relay pumping operations?
Signup and view all the answers
What does the PDP formula represent in relay pumping operations?
What does the PDP formula represent in relay pumping operations?
Signup and view all the answers
What is the role of the Water Supply Officer (WSO) during water shuttle operations?
What is the role of the Water Supply Officer (WSO) during water shuttle operations?
Signup and view all the answers
What is the minimum fill rate recommended for a water tender during shuttle operations?
What is the minimum fill rate recommended for a water tender during shuttle operations?
Signup and view all the answers
When placing cones at a fill site, what is the recommended placement in relation to the driver's door?
When placing cones at a fill site, what is the recommended placement in relation to the driver's door?
Signup and view all the answers
What is the recommended method of supplying water to the attack engine during a water shuttle operation when the first tender arrives at the scene?
What is the recommended method of supplying water to the attack engine during a water shuttle operation when the first tender arrives at the scene?
Signup and view all the answers
What is the primary purpose of a Make and Break person during a water shuttle operation?
What is the primary purpose of a Make and Break person during a water shuttle operation?
Signup and view all the answers
When using a float a pump, where should the source pumper be placed in relation to the pump?
When using a float a pump, where should the source pumper be placed in relation to the pump?
Signup and view all the answers
What action should the Driver Operator take when the onboard water tank reaches 25% capacity?
What action should the Driver Operator take when the onboard water tank reaches 25% capacity?
Signup and view all the answers
How long will it take to deplete a standard 750-gallon water tank when flowing at 150 gpm?
How long will it take to deplete a standard 750-gallon water tank when flowing at 150 gpm?
Signup and view all the answers
What is the recommended maximum flow rate from the onboard tank water?
What is the recommended maximum flow rate from the onboard tank water?
Signup and view all the answers
What is the water capacity of a standard Rescue Pumper?
What is the water capacity of a standard Rescue Pumper?
Signup and view all the answers
What is the purpose of using radio alert tones during an emergency evacuation?
What is the purpose of using radio alert tones during an emergency evacuation?
Signup and view all the answers
At what percentage of remaining tank water does an Emergency Evacuation procedure take place?
At what percentage of remaining tank water does an Emergency Evacuation procedure take place?
Signup and view all the answers
Which of the following is NOT a water delivery method mentioned in the content?
Which of the following is NOT a water delivery method mentioned in the content?
Signup and view all the answers
How often should the Driver Operator advise command and crews when the tank levels drop?
How often should the Driver Operator advise command and crews when the tank levels drop?
Signup and view all the answers
What is the recommended speed limit when laying 5" supply lines to and from a hydrant to prevent accidental dropping on the tailboard?
What is the recommended speed limit when laying 5" supply lines to and from a hydrant to prevent accidental dropping on the tailboard?
Signup and view all the answers
What are the three factors relating to hydrants that may influence fire department operations during a fire incident?
What are the three factors relating to hydrants that may influence fire department operations during a fire incident?
Signup and view all the answers
What is the minimum capacity of a water tank required by county code for construction sites that do not have fire hydrants yet installed?
What is the minimum capacity of a water tank required by county code for construction sites that do not have fire hydrants yet installed?
Signup and view all the answers
Which of these is NOT a type of water source commonly found in Palm Beach County?
Which of these is NOT a type of water source commonly found in Palm Beach County?
Signup and view all the answers
What is the common thread size found on water tank/cisterns that are used as fire department water supply?
What is the common thread size found on water tank/cisterns that are used as fire department water supply?
Signup and view all the answers
What is the main characteristic that distinguishes Reclaimed Water Flushing hydrants from other hydrants?
What is the main characteristic that distinguishes Reclaimed Water Flushing hydrants from other hydrants?
Signup and view all the answers
What is the color code used in the Water Source Locator software to identify a reliable drafting site?
What is the color code used in the Water Source Locator software to identify a reliable drafting site?
Signup and view all the answers
What is the significance of a green tag on a dry hydrant?
What is the significance of a green tag on a dry hydrant?
Signup and view all the answers
Who is responsible for notifying the water utility company of the need to boost hydrant pressure during an incident?
Who is responsible for notifying the water utility company of the need to boost hydrant pressure during an incident?
Signup and view all the answers
Which of the following is considered the best option for water operations, if given the option?
Which of the following is considered the best option for water operations, if given the option?
Signup and view all the answers
What is the primary benefit of utilizing Modified Direct Pumping in rural areas with limited water supply?
What is the primary benefit of utilizing Modified Direct Pumping in rural areas with limited water supply?
Signup and view all the answers
During Modified Direct Pumping operations, which units should be positioned close to the attack engine but out of the way of other apparatus?
During Modified Direct Pumping operations, which units should be positioned close to the attack engine but out of the way of other apparatus?
Signup and view all the answers
When is it recommended to transition from Modified Direct Pumping operations to Relay Pumping?
When is it recommended to transition from Modified Direct Pumping operations to Relay Pumping?
Signup and view all the answers
According to NFPA 1901, what is the minimum average flow rate required for tenders to dump their tanks?
According to NFPA 1901, what is the minimum average flow rate required for tenders to dump their tanks?
Signup and view all the answers
During Folding/Dump Tank operations, why are two hard suction sections recommended?
During Folding/Dump Tank operations, why are two hard suction sections recommended?
Signup and view all the answers
Which of the following is a major limitation of Folding/Dump Tank operations, making it less ideal for some situations?
Which of the following is a major limitation of Folding/Dump Tank operations, making it less ideal for some situations?
Signup and view all the answers
What is the primary concern when considering the location of a dump site for Folding/Dump Tank operations?
What is the primary concern when considering the location of a dump site for Folding/Dump Tank operations?
Signup and view all the answers
Flashcards
Water Supply Methods
Water Supply Methods
Various techniques to deliver water for fireground operations, including hydrants and tank supplies.
Driver Operator Radio Designation
Driver Operator Radio Designation
Radio designation for a driver operator on E51 is Driver Engine 5-1.
Water Capacity of Engines
Water Capacity of Engines
Engines typically have a water capacity of 750 or 1000 gallons.
Emergency Evacuation Definition
Emergency Evacuation Definition
Signup and view all the flashcards
Tank Water Depletion Notification
Tank Water Depletion Notification
Signup and view all the flashcards
Source Engine
Source Engine
Signup and view all the flashcards
Attack Engine
Attack Engine
Signup and view all the flashcards
Relay Pumpers
Relay Pumpers
Signup and view all the flashcards
Friction Loss
Friction Loss
Signup and view all the flashcards
Pump Discharge Pressure (PDP)
Pump Discharge Pressure (PDP)
Signup and view all the flashcards
Water Supply Officer (WSO)
Water Supply Officer (WSO)
Signup and view all the flashcards
Nurse Tender Operations
Nurse Tender Operations
Signup and view all the flashcards
Direct Pumping
Direct Pumping
Signup and view all the flashcards
Water Shuttle Operations
Water Shuttle Operations
Signup and view all the flashcards
Static Water Source
Static Water Source
Signup and view all the flashcards
Emergency Traffic Procedure
Emergency Traffic Procedure
Signup and view all the flashcards
Personnel Accountability Report (PAR)
Personnel Accountability Report (PAR)
Signup and view all the flashcards
National Standard Thread (NST)
National Standard Thread (NST)
Signup and view all the flashcards
Operational Hydrant Symbol
Operational Hydrant Symbol
Signup and view all the flashcards
Non-Operational Hydrant Symbol
Non-Operational Hydrant Symbol
Signup and view all the flashcards
Dry Hydrants
Dry Hydrants
Signup and view all the flashcards
Drafting Process
Drafting Process
Signup and view all the flashcards
Relay Pumping
Relay Pumping
Signup and view all the flashcards
Water Source Locator Software
Water Source Locator Software
Signup and view all the flashcards
Monthly Hydrant Water Usage Log
Monthly Hydrant Water Usage Log
Signup and view all the flashcards
Communications Center Role
Communications Center Role
Signup and view all the flashcards
Cistern Requirements
Cistern Requirements
Signup and view all the flashcards
Hydrant Documentation
Hydrant Documentation
Signup and view all the flashcards
Check Valve Function
Check Valve Function
Signup and view all the flashcards
Modified Direct Pumping
Modified Direct Pumping
Signup and view all the flashcards
Direct Pumping Limits
Direct Pumping Limits
Signup and view all the flashcards
6000 Gallons Water Supply
6000 Gallons Water Supply
Signup and view all the flashcards
Folding/Dump Tank Operations
Folding/Dump Tank Operations
Signup and view all the flashcards
Dump Site Considerations
Dump Site Considerations
Signup and view all the flashcards
Fill Site Purpose
Fill Site Purpose
Signup and view all the flashcards
Limitations of Folding/Dump Tanks
Limitations of Folding/Dump Tanks
Signup and view all the flashcards
Transition to Relay Pumping
Transition to Relay Pumping
Signup and view all the flashcards
Location of Fill Site
Location of Fill Site
Signup and view all the flashcards
Drafting from Dump Tank
Drafting from Dump Tank
Signup and view all the flashcards
Positioning Tenders
Positioning Tenders
Signup and view all the flashcards
Low Level Strainer
Low Level Strainer
Signup and view all the flashcards
Time to Dump Tank
Time to Dump Tank
Signup and view all the flashcards
Booster Line Purpose
Booster Line Purpose
Signup and view all the flashcards
Spotter Role
Spotter Role
Signup and view all the flashcards
Optimal Draft Site
Optimal Draft Site
Signup and view all the flashcards
Back Flush Pumps
Back Flush Pumps
Signup and view all the flashcards
Cone Positioning
Cone Positioning
Signup and view all the flashcards
Tender Filling Rate
Tender Filling Rate
Signup and view all the flashcards
Tender Apparatus
Tender Apparatus
Signup and view all the flashcards
Water Shuttle Route
Water Shuttle Route
Signup and view all the flashcards
Float Pump Limitations
Float Pump Limitations
Signup and view all the flashcards
Iso Rating Requirement
Iso Rating Requirement
Signup and view all the flashcards
Water Tank Depletion Time
Water Tank Depletion Time
Signup and view all the flashcards
Emergency Evacuation Water Level
Emergency Evacuation Water Level
Signup and view all the flashcards
Tank Level Notifications
Tank Level Notifications
Signup and view all the flashcards
Tender Water Capacity
Tender Water Capacity
Signup and view all the flashcards
Aerial Water Capacity
Aerial Water Capacity
Signup and view all the flashcards
Brush Truck Water Capacity
Brush Truck Water Capacity
Signup and view all the flashcards
Direct Pumping Limitation
Direct Pumping Limitation
Signup and view all the flashcards
Communication During Evacuation
Communication During Evacuation
Signup and view all the flashcards
Long Narrow Driveways
Long Narrow Driveways
Signup and view all the flashcards
Tender Dump Time
Tender Dump Time
Signup and view all the flashcards
Limitations of Folding/Dump Operations
Limitations of Folding/Dump Operations
Signup and view all the flashcards
PDP (Pump Discharge Pressure)
PDP (Pump Discharge Pressure)
Signup and view all the flashcards
Relay Requirements
Relay Requirements
Signup and view all the flashcards
Take Care of Float Pumps
Take Care of Float Pumps
Signup and view all the flashcards
Hydrant Data Information
Hydrant Data Information
Signup and view all the flashcards
Pre-determined Water Main Size
Pre-determined Water Main Size
Signup and view all the flashcards
Notification of OOS Hydrants
Notification of OOS Hydrants
Signup and view all the flashcards
Dry Hydrant Functionality
Dry Hydrant Functionality
Signup and view all the flashcards
Monthly Hydrant Usage Submission
Monthly Hydrant Usage Submission
Signup and view all the flashcards
Static Water Sources Examples
Static Water Sources Examples
Signup and view all the flashcards
Relay Pumping Method
Relay Pumping Method
Signup and view all the flashcards
Cistern Water Supply Requirements
Cistern Water Supply Requirements
Signup and view all the flashcards
Emergency Evacuation Protocol
Emergency Evacuation Protocol
Signup and view all the flashcards
Study Notes
Water Delivery Methods for Fireground Operations
- Tank Supply: Utilizing onboard water tanks for initial fire attack.
- Hydrant: Connecting to a pressurized water source.
- Static Water Source: Drawing water from natural bodies of water (oceans, canals, lakes, ponds, swimming pools).
- Water Tank/Cisterns: Utilizing gravity-fed tanks for water supply; contractor-provided tanks minimum 20,000 gallons with signage and within 400 feet of the structure.
- Relay Pumping: Pumping water through a hose to multiple fire apparatus.
- "Source" engine at water source.
- "Attack" engine at fire scene.
- "Relay" pumpers between source and attack.
- Establish relay if attack engine is over 500 feet from hydrant (3" supply line, 300 feet).
- Prioritize largest capacity pump at source.
- PDP = Friction Loss + 20 psi (residual pressure).
- Start at 50 psi, adjust after PDP.
- Intake pressure maintains at least 20 psi.
- Consider water volume and distance.
- Driver monitors ground conditions around parked engines.
- Source engine, RPM mode; other units, PSI mode when using governor.
- Goal: Similar RPM for all engines in relay.
- Water Shuttle Operations: Transporting water from a fill site to the fire scene; used when water source is remote and relay impractical.
- Participants: Tenders, engines, or brush trucks.
- WSO may appoint Dump Site and/or Fill Site supervisors; communicates with IC.
- Three Primary Rural Types: Nurse Tender, Modified Direct Pumping, Folding/Dump tank operations.
- Nurse Tender: Tender positioned adjacent to the attack engine for rapid water supply.
- 5" line from tender to attack engine.
- Rapid water delivery often controls fire before refill is needed.
- Recommended for short duration fires (rooms, garages, sheds).
- Transition to relay if incident prolonged.
- Attack engine keeps onboard tank full.
- Direct Pumping: Two apparatus supplying a single attack engine via a Siamese appliance.
- Attack Engine lays supply line.
- Next unit connects Siamese and pumps at half pressure.
- Water remains static due to higher pressure on Siamese from first apparatus.
- Second unit takes over as first runs out of water.
- Limits water supply to 500 gpm due to 3" hose critical velocity.
- Modified Direct Pumping: Multiple supply apparatus simultaneously supplying a single attack engine through multiple lines.
- Recommended for first due on confirmed structure fires in rural areas with limited water.
- All units on scene as supply pumpers.
- 6,000 gallons immediately (2 engines, 2 brush trucks, 1 tender).
- Brush trucks close to attack engine, tenders clear for access/egress.
- Transition to relay ASAP if incident prolonged.
- Folding/Dump Tank Operations: Utilizing portable tanks; not the first choice in rural areas.
- Dump Site (tank placement), Fill Site (reloading).
- First arriving tender connects to attack engine, supplies water.
- Multiple units directed by spotter for optimal dumping.
- Tenders dump full tanks in ~3-4 minutes.
- NFPA 1901: Tenders dump at a minimum 1000 gpm for 90% of tank.
- Optional: Supply engine at folding/dump tank for draft and relay.
- Low level strainer for drafting, ~2 inches.
Radio Designations (E51)
- Driver: Driver Engine 5-1
- Firefighter: Fighter Engine 5-1
- Officer: Engine 5-1
Apparatus Water Capacities
- Engines: 750 or 1000 gallons
- Aerials: 500 gallons
- Brush Trucks: 500 or 750 gallons
- Tenders: 3,000 gallons
- 600 Series Brush Trucks: 300 gallons
- Rescue Pumpers: 300 gallons
Tank Water Depletion
- Driver Operator Notification: Advise command when tank levels reach 50% and 25% full.
- Flow Rate (750 Gallons): 150 gpm depletes in ~5 minutes.
- Maximum Flow Rate Recommendation: 200 gpm maximum unless connected to secure source.
- Emergency Evacuation Threshold: 25% water remaining.
- Radio alert tones sound; evacuate to rally point.
- Emergency traffic procedures in effect; air horns.
- Personnel report to supervisor or designated area.
- IC performs Personnel Accountability Review (PAR).
- SOG 220-01 for Personnel Accountability.
- Mechanical problems: Notify IC, emergency evacuation if necessary.
Hydrant Information
- Threading: National Standard Thread (NST/NHT)
- Openings: 2 - 2.5" side ports, 1 - 4.5" steamer opening.
- Hydrant Data Source: Water Source Locator software; locations, static pressure, flow, drafting sites, dry hydrants.
- Hydrant Status Indicator: Green = Operational, Red = Non-Operational.
- Hydrant Factors on Operations: Location, operation, and flow.
- Unknown Information in Quick Access Survey: Size of water main.
- Hydrant Information Request: Communications Center or water department.
- Water Utility Contact: IC directs Communications Center.
- Battalion Water Usage: Monthly hydrant water usage submitted to Water Officer, documented in FR-B-103 (Monthly Hydrant Water Usage Log) includes refills, truck checks, training, and emergencies.
- Dry Hydrants: Tested and tagged annually (PBC Fire code).
- Tag colors: Green = Operational, Red = Non-functional.
- Check valve location: Between steamer port and source; marked "CV-No Back-Flush".
- Back-flushing: Required for dry hydrants without check valves.
- Suction size: 6" NST or 4.5" NST (with possible adapters).
- Color on Water Source Locator: Orange hydrant.
- 5" supply lines: Driving speed 10-15 mph, do not exceed 15 mph.
- Reclaimed Water Flushing Hydrants: Purple/pink color, highly chlorinated for irrigation only (not secure water source), last resort.
Fill Site Considerations
- Location: Optimal location at hydrant, considering distance/flow.
- For static sources, minimum pump capacity 1250 gpm.
- Equipment: 5" lines at hydrant; 1250+ gpm for static source filling.
- Cones: Driver visibility in fill/dump.
- Make/Break: Responsible for connections.
General Recommendations for Water Supply Operations
- Pre-Incident Planning: Crucial in non-hydrant areas.
- Deployment Decisions: Informed decisions based on incident information.
- Supply Engine Use: If possible, establish draft and relay water.
Rural Fire Considerations
- Minimum Water Considerations: Typical residence size requires 2,000-10,000 gallons for water.
- Average Fire Flow: 250-500 gpm.
- Lot Size: 1.25-acre lot is approximately 200 feet wide.
- Minimum Deployment: Request a secondary tender in rural responses.
- Water Volume/Deployment Capacity Calculations: IC or WSO uses formula.
- Initial Tender Responsiveness: Within 5 minutes of arrival, begin dumping water, minimum 250 gpm for 2 hours.
- Float a Pump: Last resort where drafting sites are inaccessible.
Water Tank/Cisterns Operation
- Supply Method: Gravity-fed, operational during water shuttles.
- Drafting: Remedy is to pull a draft. Ensure vent openings are open.
- Common Thread Sizes: 4 ½ NST male threads/ 6" - 4 ½" adapter.
Tender Apparatus considerations
- Carries 3000 gallons
- Carry extra foam and SCBA on scene
Dump Site considerations
- Level, unobstructed ground is ideal.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge on key firefighting protocols, including equipment specifications and emergency procedures. This quiz covers radio designations, water flow rates, and evacuation protocols crucial for firefighter effectiveness and safety.