Podcast
Questions and Answers
What is the primary purpose of the Fire Service Option in elevators?
What is the primary purpose of the Fire Service Option in elevators?
- To allow firefighters to control the elevator from inside the car. (correct)
- To enable automatic door closing mechanisms.
- To enhance passenger safety during regular use.
- To provide emergency lighting in case of power failure.
How is an elevator featuring the Fire Service Option typically recalled?
How is an elevator featuring the Fire Service Option typically recalled?
- By a physical key operated by authorized personnel.
- Through the activation of a smoke detector or fire alarm. (correct)
- Automatically by the elevator's internal timer.
- Via a manual switch located inside the elevator car.
What must firefighters do after the elevator returns automatically to the lobby?
What must firefighters do after the elevator returns automatically to the lobby?
- Immediately enter the elevator to begin operations.
- Override the elevator settings using a computer interface.
- Deactivate the fire alarm system before use.
- Place the lobby control switch in the 'ON' position. (correct)
What should be done with the key after it is used to recall the elevator to firefighter service?
What should be done with the key after it is used to recall the elevator to firefighter service?
Which action is necessary for ensuring the elevator doors close properly?
Which action is necessary for ensuring the elevator doors close properly?
What is the correct procedure after reaching the desired floor with the elevator?
What is the correct procedure after reaching the desired floor with the elevator?
Which statement about the Fire Service Option is accurate?
Which statement about the Fire Service Option is accurate?
What is a critical safety feature of elevators equipped with the Fire Service Option?
What is a critical safety feature of elevators equipped with the Fire Service Option?
Study Notes
Hoffman Estates Fire Department Standard Operating Guidelines
Fire Scene Operations - Use of Elevator with Fire Service Option
- Fire Service Option is a feature in an elevator that allows firefighters or authorized personnel to control the elevator from inside the car by locking out hall call buttons.
- Purpose: to enable firefighters to operate the elevator safely and efficiently during emergency situations.
Procedure for Operating Elevator with Fire Service Option
- An elevator with Fire Service Option can be recalled: • Automatically upon actuation of a smoke detector or fire alarm pull station • By operating the key-actuated switch, usually located on the wall adjacent to the elevator at the lobby level
- When the service is actuated, the elevator returns to the lobby non-stop.
- Precautions for firefighters operating an elevator with Fire Service Option: • Place the lobby control switch in the "ON" position to restore the elevator to firefighter use if it returns automatically • Remove the key and place it in the key-actuated switch inside the car, turn it to the "on" position to gain total control from inside the car • Depress the desired floor button on the car's operating panel • Depress and hold the door "close" button until the door is fully closed • After reaching the desired floor, depress and hold the door "open" switch until the door is fully opened