Podcast
Questions and Answers
Where smoke is reported on several floors get off __ floors below the lowest reported. Make sure you know what floors contain ____ stairs
Where smoke is reported on several floors get off __ floors below the lowest reported. Make sure you know what floors contain ____ stairs
Two, access
If the fire is within _ floors of the elevator lobby or sky lobby walk up
If the fire is within _ floors of the elevator lobby or sky lobby walk up
8
Ensure that each unit that enters a elevator has its ___ number, unit and ____ recorded by a ff who is designated ____ control
Ensure that each unit that enters a elevator has its ___ number, unit and ____ recorded by a ff who is designated ____ control
Car, destination, lobby
Each team that enter an elevator should have forcible entry tools and a ____ radio as well as have their SCBA turned ___
Each team that enter an elevator should have forcible entry tools and a ____ radio as well as have their SCBA turned ___
Signup and view all the answers
Upon entering a car immediately hit the ____ button to eliminate any selections previously made
Upon entering a car immediately hit the ____ button to eliminate any selections previously made
Signup and view all the answers
Use only firefighter ____ elevators which are placed in proper operation by a key or other secure means
Use only firefighter ____ elevators which are placed in proper operation by a key or other secure means
Signup and view all the answers
The most important point to make about ff service elevators are that they are not ____, totally safe devices
The most important point to make about ff service elevators are that they are not ____, totally safe devices
Signup and view all the answers
____ or service elevators don’t make good elevators to use since they usually serve every floor
____ or service elevators don’t make good elevators to use since they usually serve every floor
Signup and view all the answers
A large number of serious fires start in accumulated _____ in freight elevator lobbies
A large number of serious fires start in accumulated _____ in freight elevator lobbies
Signup and view all the answers
As soon as the car begins to move from the lobby, press the ____ stop button
As soon as the car begins to move from the lobby, press the ____ stop button
Signup and view all the answers
The trip up to the two floors below fire floor should consist of stops every __ floors
The trip up to the two floors below fire floor should consist of stops every __ floors
Signup and view all the answers
Stopping every 5 floors allows you to verify the elevator is still responding and it allows you to step out and verify the location of the nearest ____ stairway
Stopping every 5 floors allows you to verify the elevator is still responding and it allows you to step out and verify the location of the nearest ____ stairway
Signup and view all the answers
If there is smoke on the floor descend __ floors and try again
If there is smoke on the floor descend __ floors and try again
Signup and view all the answers
If the hall is clear ensure you can get into the ____ before everyone exits the elevator
If the hall is clear ensure you can get into the ____ before everyone exits the elevator
Signup and view all the answers
Don’t stand inside the car doors to hold it open, lay a length of ___ or have a member remain in the car holding the door ____ button
Don’t stand inside the car doors to hold it open, lay a length of ___ or have a member remain in the car holding the door ____ button
Signup and view all the answers
A member must remain with the elevator at all times because it only responds to door open from within the elevator this members title is nicknamed ____
A member must remain with the elevator at all times because it only responds to door open from within the elevator this members title is nicknamed ____
Signup and view all the answers
The personnel of Atleast ___ ladder companies are needed on the fire floor and ___ truck company on the floor above to preform search and rescue and check for extension
The personnel of Atleast ___ ladder companies are needed on the fire floor and ___ truck company on the floor above to preform search and rescue and check for extension
Signup and view all the answers
For fires with open ceiling space and a bunch of partitions below a 2 1/2 in line with a ____ solid tip is the preferred hoseline
For fires with open ceiling space and a bunch of partitions below a 2 1/2 in line with a ____ solid tip is the preferred hoseline
Signup and view all the answers
NFPA 14, 2016 edition states that fire pumps are only required to discharge their capacity at __ psi at the highest hose outlet and a max of ___ psi. The old standard allowed for as little as ___ psi at the top floor outlet prior to 1993
NFPA 14, 2016 edition states that fire pumps are only required to discharge their capacity at __ psi at the highest hose outlet and a max of ___ psi. The old standard allowed for as little as ___ psi at the top floor outlet prior to 1993
Signup and view all the answers
The standard class a pumper is rated to deliver ___ of its capacity at ___ psi
The standard class a pumper is rated to deliver ___ of its capacity at ___ psi
Signup and view all the answers
You need a nozzle that can put out an effective fire stream (___gpm) at as low as __ psi nozzle pressure (the 1 1/4 solid tip)
You need a nozzle that can put out an effective fire stream (___gpm) at as low as __ psi nozzle pressure (the 1 1/4 solid tip)
Signup and view all the answers
Many lightweight master stream devices can be carried by __ member up __ flights
Many lightweight master stream devices can be carried by __ member up __ flights
Signup and view all the answers
One of the problems with lightweight master stream devices is their tendency to kick back when the stream angle is lowered to ____ degrees which is necessary for 8-9ft ceilings
One of the problems with lightweight master stream devices is their tendency to kick back when the stream angle is lowered to ____ degrees which is necessary for 8-9ft ceilings
Signup and view all the answers
The first method to securing these master stream devices is with two steel handled _____ hooks to span a door opening
The first method to securing these master stream devices is with two steel handled _____ hooks to span a door opening
Signup and view all the answers
You can deploy upward of ___ gpm with these lightweight master stream devices applied from the door of the fire stairs or door to the office area
You can deploy upward of ___ gpm with these lightweight master stream devices applied from the door of the fire stairs or door to the office area
Signup and view all the answers
It’s best to supply these portable monitor devices with ___ 2 1/2 in or larger lines. That means the second line will have to be stretched from the outlet __ floors below the fire. In this test that meant __ lengths of hose. This permitted up to 750gpm
It’s best to supply these portable monitor devices with ___ 2 1/2 in or larger lines. That means the second line will have to be stretched from the outlet __ floors below the fire. In this test that meant __ lengths of hose. This permitted up to 750gpm
Signup and view all the answers
Rescue 1 fastens two __ in shanks x _ in deep x 3/8 diameter threaded powder driven studs using a .38 cal powder driven actuated fastener. Secured with the devices ___, utility rope or tubular nylon webbing
Rescue 1 fastens two __ in shanks x _ in deep x 3/8 diameter threaded powder driven studs using a .38 cal powder driven actuated fastener. Secured with the devices ___, utility rope or tubular nylon webbing
Signup and view all the answers
This fastening method used is designed to provide 4,360lb of resistance in the ___ mode. This provides a ___ safety factor against the ___ lbs of nozzle reaction produced by a 1 3/4 tip flowing at 80psi
This fastening method used is designed to provide 4,360lb of resistance in the ___ mode. This provides a ___ safety factor against the ___ lbs of nozzle reaction produced by a 1 3/4 tip flowing at 80psi
Signup and view all the answers
Core construction can provide floor spaces in excess of _____ square feet per floor
Core construction can provide floor spaces in excess of _____ square feet per floor
Signup and view all the answers
Prior to 1993 NFPA only required a standpipe system to supply a max of ____ gpm. In the revision that number was lowered to ___ gpm
Prior to 1993 NFPA only required a standpipe system to supply a max of ____ gpm. In the revision that number was lowered to ___ gpm
Signup and view all the answers
You can use a ____ core drill or concrete cuttting ____ as a last resort to get water on fire from safe areas in an otherwise untenable area
You can use a ____ core drill or concrete cuttting ____ as a last resort to get water on fire from safe areas in an otherwise untenable area
Signup and view all the answers
The floor below nozzle only provides ___ to ____ gpm
The floor below nozzle only provides ___ to ____ gpm
Signup and view all the answers
The concrete core drill is a diamond tipped drill that can bore holes up to ___ in diameter
The concrete core drill is a diamond tipped drill that can bore holes up to ___ in diameter
Signup and view all the answers
There are two styles of the concrete core drill one is _____ and the other is ____ driven, which only drills __ in holes which are to small to pass a 2 1/2 in Bresnan or other distributer
There are two styles of the concrete core drill one is _____ and the other is ____ driven, which only drills __ in holes which are to small to pass a 2 1/2 in Bresnan or other distributer
Signup and view all the answers
Both models require pump tank of water to cool bits, normally they are held in place with powder activated fastener and using ____nuts to hold the drill
Both models require pump tank of water to cool bits, normally they are held in place with powder activated fastener and using ____nuts to hold the drill
Signup and view all the answers
A __ in hole is large enough for a ____ or cellar pipe
A __ in hole is large enough for a ____ or cellar pipe
Signup and view all the answers
A 2 1/2 in bresnan distributer operating at ___ psi flows ___ gpm and covers a 20-25ft radius pg 473
A 2 1/2 in bresnan distributer operating at ___ psi flows ___ gpm and covers a 20-25ft radius pg 473
Signup and view all the answers
The drilling of a ___ in floor can be done in 5 minutes
The drilling of a ___ in floor can be done in 5 minutes
Signup and view all the answers
According to John t o Hagans book high rise fire and life safety, areas in excess of ____ square ft of a moderately fuel loaded area diminish the possibility of success through a direct attack
According to John t o Hagans book high rise fire and life safety, areas in excess of ____ square ft of a moderately fuel loaded area diminish the possibility of success through a direct attack
Signup and view all the answers
Atleast one manufacturer makes a cellar pipe that will pass through a 4 in hole that will flow ___ gpm
Atleast one manufacturer makes a cellar pipe that will pass through a 4 in hole that will flow ___ gpm
Signup and view all the answers