3A2E3 C15 Obj 6

WholesomeMaroon avatar
WholesomeMaroon
·
·
Download

Start Quiz

15 Questions

Which type of hydrant is used when there is a chance the temperature will drop below freezing?

Dry barrel hydrant

What is the purpose of the hydrostatic pressure test of the pump casing?

To check for leakage

What is the purpose of using the test line on the pump discharge during annual testing?

To direct the flow through an orifice

What is the minimum requirement for testing fire pumps annually?

Capacity testing

What is the recommended method for detecting freezing in hydrants?

Lowering a weight on a stout string into the hydrant

Which type of hydrant is used in areas where temperatures remain above freezing?

Wet barrel hydrant

What is the purpose of the drain valve at the base of the barrel in the dry barrel hydrant?

To allow residual water to drain out

What is the minimum duration for maintaining twice the maximum design working pressure during the hydrostatic pressure test of the pump casing?

5 minutes

What is the recommended method for thawing a frozen hydrant?

Using a steam hose

What is the purpose of the annual capacity testing of fire pumps?

To ensure the pump can deliver 150% of the design flow

Which of the following is NOT a purpose of the annual testing of fire pumps?

To manipulate the valves to achieve a pressure that is 65% of design pressure

What is the minimum duration for maintaining twice the maximum design working pressure during the hydrostatic pressure test of the pump casing?

5 minutes

Which of the following is NOT a recommended method for detecting freezing in hydrants?

Using salt or salt solutions to prevent freezing

What is the purpose of the drain valve at the base of the barrel in the dry barrel hydrant?

To drain residual water out of the barrel

What is the purpose of the test line on the pump discharge during annual testing?

To measure the flow using a flow meter

Study Notes

Fire Hydrants and Pumps

  • Dry barrel hydrants are used in areas where the temperature may drop below freezing.
  • Wet barrel hydrants are used in areas where temperatures remain above freezing.

Hydrostatic Pressure Test

  • The purpose of the hydrostatic pressure test of the pump casing is to ensure the pump can withstand twice the maximum design working pressure.
  • The minimum duration for maintaining twice the maximum design working pressure during the hydrostatic pressure test is not specified.

Annual Testing of Fire Pumps

  • The purpose of the annual capacity testing of fire pumps is to ensure the pump can meet its rated capacity.
  • The minimum requirement for testing fire pumps annually is not specified.
  • The test line on the pump discharge is used during annual testing to measure the pump's capacity.

Detecting and Thawing Frozen Hydrants

  • The recommended method for detecting freezing in hydrants is to use a pressure gauge or thermometer.
  • The recommended method for thawing a frozen hydrant is not specified.

Dry Barrel Hydrants

  • The drain valve at the base of the barrel in the dry barrel hydrant is used to drain water from the hydrant to prevent freezing.

Purpose of Annual Testing

  • The purpose of the annual testing of fire pumps is to ensure the pump is functioning properly and can meet its rated capacity.
  • The annual testing of fire pumps is NOT used to determine the pump's flow rate.

Quiz: Types of Fire Hydrants Test your knowledge on the construction and operation of fire hydrants with this informative quiz. Learn about the two general types of fire hydrants, including the most common base valve (dry barrel) type. Enhance your understanding of these crucial fire protection systems.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

Fire Officer Chapter 6 160-177
64 questions
Fire Hydrant Water Supply System
20 questions
Use Quizgecko on...