Questions and Answers

How many feet from a hospital must audible warning devices be turned off?

  • 400 FEET
  • 300 FEET
  • 100 FEET
  • 200 FEET (correct)
  • What is the recommended RPM range for diesel apparatus under no load conditions?

  • 900-1000 RPM (correct)
  • 800-900 RPM
  • 1000-1100 RPM
  • 1100-1200 RPM
  • How often should apparatus with a booster tank have the tank and pump completely drained and flushed?

  • Once per week
  • Once per quarter
  • Once per year
  • Once per month (correct)
  • When should oil levels be checked?

    <p>After 5 MINUTES of cooling down</p> Signup and view all the answers

    How often should preventative maintenance be performed on aerial ladder slides and rails?

    <p>Quarterly</p> Signup and view all the answers

    How many days prior to the scheduled date should state inspections be completed?

    <p>45 DAYS</p> Signup and view all the answers

    When should IV fluids and medications be removed from an ambulance?

    <p>When temperatures are above 86 or below 59 degrees Fahrenheit</p> Signup and view all the answers

    What is the minimum engine hours requirement for preventative maintenance of structural apparatus?

    <p>450 engine hours</p> Signup and view all the answers

    How often will battalion chiefs perform safety equipment quality assurance checks?

    <p>Bi-Monthly</p> Signup and view all the answers

    What is the temperature range for PPE storage areas?

    <p>-25 or 180 degrees Fahrenheit</p> Signup and view all the answers

    How often will ensembles that are issued and used receive advanced cleaning?

    <p>Every 6 months</p> Signup and view all the answers

    When will a risk assessment be revised for SCBA procurement?

    <p>Every 5 years</p> Signup and view all the answers

    What is the minimum acceptable air pressure for SCBA?

    <p>Above 90% of the cylinders operating capacity</p> Signup and view all the answers

    How often will hydrostatic testing be performed on department SCBA?

    <p>Every 5 years</p> Signup and view all the answers

    What is the standard for protective clothing purchased by the department?

    <p>NFPA 1971</p> Signup and view all the answers

    How long will advanced inspection data be maintained at the station?

    <p>2 years</p> Signup and view all the answers

    Study Notes

    Vehicle Operations

    • Audible warning devices are turned off within 200 feet of hospitals
    • Diesel apparatus should be run at idle between 900-1000 RPM under no load conditions for a minimum of 4 minutes before stopping the engine
    • Each company has been issued 5 traffic cones

    Maintenance Schedules

    • Apparatus with booster tanks are drained and flushed once a month
    • Oil levels should be checked 5 minutes after shutting down the engine
    • Transmission fluid should be checked after 20-30 minutes of operation
    • Apparatus that use more than 1 gallon of 50/50 mix within 2 months will be scheduled for diagnostic testing
    • Preventative maintenance for aerial ladders should be performed at least quarterly
    • All state inspections must be completed 45 days prior to the scheduled date

    Scheduling and Operations

    • Units will be scheduled for maintenance at 0730 or 1230 hours
    • If a unit is going to be more than 15 minutes late, it will not report
    • Vehicles will be scheduled for maintenance at the following intervals:
      • 6000 miles for Battalion and ROC
      • 450 engine hours for structural apparatus
      • 250 engine hours for ambulance

    Medical and Safety Protocols

    • IV fluids and medications will be removed when temperatures are below 59 or above 86 degrees Fahrenheit
    • Ambulances involved in minor accidents may proceed to the hospital if damage is less than $500 and there are no injuries
    • The safety equipment quality assurance program is established to maintain and ensure firefighter safety

    Safety Equipment and PPE

    • Items will be cared for and maintained in accordance with NFPA 1851
    • Battalion chiefs will perform bi-monthly safety equipment quality assurance checks of each station within their battalion
    • Protective clothing purchased by the department will comply with or exceed NFPA 1971
    • Risk assessments will be completed by the department prior to procurement of any SPFC and will be revised every 2 years
    • PPE storage areas should not exceed -25 or 180 degrees Fahrenheit
    • Ensembles that are issued and used will receive advanced cleaning at least every 6 months
    • Advanced inspections are done every 12 months
    • Components will be retired after 10 years from the date of manufacture or when damaged beyond repair

    SCBA and Air Quality

    • SCBA will be used at 19.5% or less of oxygen
    • SCBA will be used at 35 ppm or more of Carbon Monoxide
    • At least ½ of a full cylinder must be remaining for EBSS
    • Sleeve of the quick disconnect for the face mask hose should be rotated one-half turn
    • Complete SCBA daily form which will be maintained at the station for a period of 2 years
    • Acceptable air pressure will be above 90% of the cylinders operating capacity