Fire Department Vehicle Operations
16 Questions
2 Views

Fire Department Vehicle Operations

Created by
@YoungTuba

Questions and Answers

How many feet from a hospital must audible warning devices be turned off?

  • 400 FEET
  • 300 FEET
  • 100 FEET
  • 200 FEET (correct)
  • What is the recommended RPM range for diesel apparatus under no load conditions?

  • 900-1000 RPM (correct)
  • 800-900 RPM
  • 1000-1100 RPM
  • 1100-1200 RPM
  • How often should apparatus with a booster tank have the tank and pump completely drained and flushed?

  • Once per week
  • Once per quarter
  • Once per year
  • Once per month (correct)
  • When should oil levels be checked?

    <p>After 5 MINUTES of cooling down</p> Signup and view all the answers

    How often should preventative maintenance be performed on aerial ladder slides and rails?

    <p>Quarterly</p> Signup and view all the answers

    How many days prior to the scheduled date should state inspections be completed?

    <p>45 DAYS</p> Signup and view all the answers

    When should IV fluids and medications be removed from an ambulance?

    <p>When temperatures are above 86 or below 59 degrees Fahrenheit</p> Signup and view all the answers

    What is the minimum engine hours requirement for preventative maintenance of structural apparatus?

    <p>450 engine hours</p> Signup and view all the answers

    How often will battalion chiefs perform safety equipment quality assurance checks?

    <p>Bi-Monthly</p> Signup and view all the answers

    What is the temperature range for PPE storage areas?

    <p>-25 or 180 degrees Fahrenheit</p> Signup and view all the answers

    How often will ensembles that are issued and used receive advanced cleaning?

    <p>Every 6 months</p> Signup and view all the answers

    When will a risk assessment be revised for SCBA procurement?

    <p>Every 5 years</p> Signup and view all the answers

    What is the minimum acceptable air pressure for SCBA?

    <p>Above 90% of the cylinders operating capacity</p> Signup and view all the answers

    How often will hydrostatic testing be performed on department SCBA?

    <p>Every 5 years</p> Signup and view all the answers

    What is the standard for protective clothing purchased by the department?

    <p>NFPA 1971</p> Signup and view all the answers

    How long will advanced inspection data be maintained at the station?

    <p>2 years</p> Signup and view all the answers

    Study Notes

    Vehicle Operations

    • Audible warning devices are turned off within 200 feet of hospitals
    • Diesel apparatus should be run at idle between 900-1000 RPM under no load conditions for a minimum of 4 minutes before stopping the engine
    • Each company has been issued 5 traffic cones

    Maintenance Schedules

    • Apparatus with booster tanks are drained and flushed once a month
    • Oil levels should be checked 5 minutes after shutting down the engine
    • Transmission fluid should be checked after 20-30 minutes of operation
    • Apparatus that use more than 1 gallon of 50/50 mix within 2 months will be scheduled for diagnostic testing
    • Preventative maintenance for aerial ladders should be performed at least quarterly
    • All state inspections must be completed 45 days prior to the scheduled date

    Scheduling and Operations

    • Units will be scheduled for maintenance at 0730 or 1230 hours
    • If a unit is going to be more than 15 minutes late, it will not report
    • Vehicles will be scheduled for maintenance at the following intervals:
      • 6000 miles for Battalion and ROC
      • 450 engine hours for structural apparatus
      • 250 engine hours for ambulance

    Medical and Safety Protocols

    • IV fluids and medications will be removed when temperatures are below 59 or above 86 degrees Fahrenheit
    • Ambulances involved in minor accidents may proceed to the hospital if damage is less than $500 and there are no injuries
    • The safety equipment quality assurance program is established to maintain and ensure firefighter safety

    Safety Equipment and PPE

    • Items will be cared for and maintained in accordance with NFPA 1851
    • Battalion chiefs will perform bi-monthly safety equipment quality assurance checks of each station within their battalion
    • Protective clothing purchased by the department will comply with or exceed NFPA 1971
    • Risk assessments will be completed by the department prior to procurement of any SPFC and will be revised every 2 years
    • PPE storage areas should not exceed -25 or 180 degrees Fahrenheit
    • Ensembles that are issued and used will receive advanced cleaning at least every 6 months
    • Advanced inspections are done every 12 months
    • Components will be retired after 10 years from the date of manufacture or when damaged beyond repair

    SCBA and Air Quality

    • SCBA will be used at 19.5% or less of oxygen
    • SCBA will be used at 35 ppm or more of Carbon Monoxide
    • At least ½ of a full cylinder must be remaining for EBSS
    • Sleeve of the quick disconnect for the face mask hose should be rotated one-half turn
    • Complete SCBA daily form which will be maintained at the station for a period of 2 years
    • Acceptable air pressure will be above 90% of the cylinders operating capacity

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers safety procedures and guidelines for fire department vehicles, including audible warnings, engine maintenance, and equipment checks.

    Use Quizgecko on...
    Browser
    Browser