Questions and Answers

Which test method is used to determine the fire and smoke characteristics of electrical wiring, cables, and non-metallic raceways?

  • Horizontal Flame Test
  • FT6 rating (correct)
  • FT4 rating
  • Vertical Flame Test - Cables in Cable Trays
  • In a plenum, which components of wiring systems are permitted if they exhibit a vertical char of not more than 1.5 m when tested?

  • Combustible insulation
  • Noncombustible raceways
  • Electrical wires and cables (correct)
  • Optical fibre cables
  • Which type of wood used in construction must be pressure impregnated with fire-retardant chemicals and have a flame-spread rating not more than 25?

  • Glued-laminated wood
  • Solid sawn plank
  • Fire-retardant-treated wood (correct)
  • Heavy timber construction
  • What is the minimum thickness required for splice plates used at splices in heavy timber construction?

    <p>64 mm</p> Signup and view all the answers

    What is the minimum thickness required for floors in heavy timber construction?

    <p>64 mm</p> Signup and view all the answers

    Which of the following materials is NOT permitted in noncombustible construction?

    <p>Foamed plastic air sealants</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, how should wood girders and beams in heavy timber construction be connected at adjoining ends?

    <p>By timber splice plates fastened with metal connectors</p> Signup and view all the answers

    What is the minimum width requirement for roof arches, roof trusses, roof beams, and roof girders in heavy timber construction?

    <p>64 mm</p> Signup and view all the answers

    In heavy timber construction, how should intermediate wood beams used to support a floor be supported?

    <p>On top of the girders</p> Signup and view all the answers

    What percentage of the exterior cladding on each exterior wall of buildings conforming to certain articles should consist of noncombustible cladding?

    <p>90%</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following is true about the classification of an arena-type building used for trade shows and similar exhibition purposes?

    <p>It is classified as a Group A, Division 3 occupancy.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the maximum building height and area for a police station with detention quarters to be classified as a Group B, Division 2 major occupancy?

    <p>1 storey in building height and 600 m2 in building area.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what are the requirements for the classification of convalescent homes and children's custodial homes?

    <p>They are classified as residential occupancies.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the classification of buildings or parts thereof used for the storage of baled combustible fibres?

    <p>They are classified as medium-hazard industrial occupancies.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the minimum fire-resistance rating of fire separation between a Group A-3 major occupancy and a Group F-2 major occupancy?

    <p>3 hours</p> Signup and view all the answers

    Which of the following is NOT considered a minor component in building construction?

    <p>Wood blocking within wall assemblies</p> Signup and view all the answers

    Which of the following roofing materials is permitted on a building required to be of noncombustible construction?

    <p>Combustible roof covering with C classification</p> Signup and view all the answers

    What is the minimum thickness required for a concrete deck supporting combustible roof sheathing and roof sheathing supports on a building required to be of noncombustible construction?

    <p>50 mm</p> Signup and view all the answers

    In a building required to be of noncombustible construction, what is the maximum height allowed for the roof space above the concrete deck if combustible roof sheathing and roof sheathing supports are installed?

    <p>1 m</p> Signup and view all the answers

    What is the purpose of fire blocks in the roof space of a building required to be of noncombustible construction?

    <p>To divide the roof space into compartments</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the definition of a storage tank?

    <p>A vessel for flammable liquids or combustible liquids with a capacity of more than 230 L</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, where can the information regarding major components of fire protection be found?

    <p>Subsection 2.2.3. of Division C</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, how should buildings or parts of buildings be classified?

    <p>According to their major occupancy</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what should be done with buildings intended for use by more than one major occupancy?

    <p>They should be classified according to all major occupancies for which they are used or intended to be used</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, where are the defined words found?

    <p>Article 1.4.1.2. of Division A</p> Signup and view all the answers

    Which one of the following is true about buildings classified as Group F, Division 2 major occupancy?

    <p>They can contain a single suite of residential occupancy.</p> Signup and view all the answers

    Which one of the following is NOT permitted in a building conforming to Article 3.2.2.50 or 3.2.2.58?

    <p>Group A, Division 2 major occupancy above the second storey</p> Signup and view all the answers

    Which one of the following is true about buildings permitted to be of combustible construction?

    <p>They can be constructed of either combustible or noncombustible materials.</p> Signup and view all the answers

    Which one of the following is a requirement for protecting foamed plastics in combustible construction?

    <p>Using a combination of all the above options.</p> Signup and view all the answers

    Which one of the following is true about walk-in coolers or freezers in a building required to be of combustible construction?

    <p>They must be protected on both sides by sheet metal.</p> Signup and view all the answers

    Combustible roof covering with an A, B, or C classification is permitted on a building required to be of noncombustible construction.

    <p>True</p> Signup and view all the answers

    Combustible roof sheathing and roof sheathing supports are permitted on a building required to be of noncombustible construction if the concrete deck is at least 50 mm thick.

    <p>True</p> Signup and view all the answers

    The maximum height of the roof space above the concrete deck is 1 m for a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports.

    <p>True</p> Signup and view all the answers

    Openings through the concrete deck, other than for noncombustible roof drains and plumbing piping, must be protected by masonry for a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports.

    <p>True</p> Signup and view all the answers

    Combustible roofing materials are not permitted on a building required to be of noncombustible construction.

    <p>False</p> Signup and view all the answers

    Combustible roof sheathing and roof sheathing supports are not permitted on a building required to be of noncombustible construction.

    <p>False</p> Signup and view all the answers

    The maximum height of the roof space above the concrete deck is 2 m for a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports.

    <p>False</p> Signup and view all the answers

    Openings through the concrete deck, other than for noncombustible roof drains and plumbing piping, do not need to be protected for a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports.

    <p>False</p> Signup and view all the answers

    Combustible roofing materials are permitted on a building required to be of noncombustible construction.

    <p>True</p> Signup and view all the answers

    Combustible roof sheathing and roof sheathing supports are permitted on a building required to be of noncombustible construction if the concrete deck is less than 50 mm thick.

    <p>False</p> Signup and view all the answers

    Combustible roof sheathing and roof sheathing supports are not permitted on a building required to be of noncombustible construction.

    <p>False</p> Signup and view all the answers

    Combustible roof covering with an A, B, or C classification is permitted on a building required to be of noncombustible construction.

    <p>True</p> Signup and view all the answers

    Openings through the concrete deck, other than for noncombustible roof drains and plumbing piping, must be protected by masonry for a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports.

    <p>True</p> Signup and view all the answers

    The maximum height of the roof space above the concrete deck is 2 m for a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports.

    <p>False</p> Signup and view all the answers

    Combustible roof sheathing and roof sheathing supports are permitted on a building required to be of noncombustible construction if the concrete deck is at least 50 mm thick.

    <p>True</p> Signup and view all the answers

    The minimum thickness required for a concrete deck supporting combustible roof sheathing and roof sheathing supports on a building required to be of noncombustible construction is 50 mm.

    <p>True</p> Signup and view all the answers

    Combustible roofing materials are not permitted on a building required to be of noncombustible construction.

    <p>False</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the maximum building height and area for a police station with detention quarters to be classified as a Group B, Division 2 major occupancy?

    <p>False</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the definition of a storage tank?

    <p>False</p> Signup and view all the answers

    What is the purpose of fire blocks in the roof space of a building required to be of noncombustible construction?

    <p>False</p> Signup and view all the answers

    Which of the following is NOT considered a minor component in a building?

    <p>Wood blocking within wall assemblies</p> Signup and view all the answers

    What is the classification of combustible roof covering allowed on a building required to be of noncombustible construction?

    <p>C</p> Signup and view all the answers

    Under what conditions are combustible roof sheathing and roof sheathing supports permitted on a building required to be of noncombustible construction?

    <p>If the concrete deck is less than 50 mm thick</p> Signup and view all the answers

    What is the purpose of fire blocks in the roof space of a building required to be of noncombustible construction?

    <p>To divide the roof space into compartments</p> Signup and view all the answers

    Which one of the following roofing materials is permitted on a building required to be of noncombustible construction?

    <p>Combustible roof covering with an A classification</p> Signup and view all the answers

    What is the maximum height allowed for the roof space above the concrete deck if combustible roof sheathing and roof sheathing supports are installed on a building required to be of noncombustible construction?

    <p>1 m</p> Signup and view all the answers

    What is the minimum thickness required for a concrete deck supporting combustible roof sheathing and roof sheathing supports on a building required to be of noncombustible construction?

    <p>50 mm</p> Signup and view all the answers

    Which one of the following is NOT permitted in a building conforming to Article 3.2.2.50 or 3.2.2.58?

    <p>Wood blocking within wall assemblies</p> Signup and view all the answers

    What is the classification of combustible roofing materials on a building required to be of noncombustible construction?

    <p>D</p> Signup and view all the answers

    What is the purpose of wood blocking within wall assemblies in a building required to be of noncombustible construction?

    <p>To provide attachment points for handrails and fixtures</p> Signup and view all the answers

    Which one of the following is NOT considered a minor component in building construction?

    <p>Tubing for pneumatic controls with an outside diameter of more than 10 mm</p> Signup and view all the answers

    What is the maximum height allowed for the roof space above the concrete deck if combustible roof sheathing and roof sheathing supports are installed on a building required to be of noncombustible construction?

    <p>1 m</p> Signup and view all the answers

    What is the purpose of fire blocks in the roof space of a building required to be of noncombustible construction?

    <p>To divide the roof space into compartments</p> Signup and view all the answers

    Which one of the following is true about buildings permitted to be of combustible construction?

    <p>Combustible roof sheathing and roof sheathing supports are allowed</p> Signup and view all the answers

    What is the definition of a storage tank?

    <p>A tank used for storing liquids or gases</p> Signup and view all the answers

    What is the minimum thickness required for a concrete deck supporting combustible roof sheathing and roof sheathing supports on a building required to be of noncombustible construction?

    <p>50 mm</p> Signup and view all the answers

    Which one of the following roofing materials is permitted on a building required to be of noncombustible construction?

    <p>Combustible roof covering with an A, B, or C classification</p> Signup and view all the answers

    What is the maximum building height and area for a police station with detention quarters to be classified as a Group B, Division 2 major occupancy according to the National Building Code of Canada 2015?

    <p>Limited height and area</p> Signup and view all the answers

    What is the purpose of fire blocks in conformance with Article 3.1.11.5. of the National Building Code of Canada 2015?

    <p>To divide the roof space into compartments</p> Signup and view all the answers

    Which one of the following is a requirement for protecting openings through the concrete deck other than for noncombustible roof drains and plumbing piping in a building required to be of noncombustible construction with combustible roof sheathing and roof sheathing supports?

    <p>Protection by maso</p> Signup and view all the answers