The specific requirements for writing and equipment installation for fire protective signaling system are covered in?
The specific requirements for writing and equipment installation for fire protective signaling system are covered in?
NFPA 70
The code established to help fire authorities continually develop safeguards against fire hazards is?
The code established to help fire authorities continually develop safeguards against fire hazards is?
NFPA 1
Which class of circuits are run in non-redundant paths to increase reliability?
Which class of circuits are run in non-redundant paths to increase reliability?
A
A defined area within the boundaries of a fire alarm system is known as a(n)?
A defined area within the boundaries of a fire alarm system is known as a(n)?
Signup and view all the answers
A fire system with zones that allow multiple signals from several sources to be sent and received over a single communication line is known as a(n)?
A fire system with zones that allow multiple signals from several sources to be sent and received over a single communication line is known as a(n)?
Signup and view all the answers
Which of the following is a type of spot detector?
Which of the following is a type of spot detector?
Signup and view all the answers
An automatic detector that draws air from the protected area back to the detector is called a(n)?
An automatic detector that draws air from the protected area back to the detector is called a(n)?
Signup and view all the answers
Which of the following is a type of fixed-temperature heat detector?
Which of the following is a type of fixed-temperature heat detector?
Signup and view all the answers
NFPA 72 prohibits a duct detector from being used as a supervisor device.
NFPA 72 prohibits a duct detector from being used as a supervisor device.
Signup and view all the answers
The CO2 spike phenomenon for hydrocarbon-based fires is used in?
The CO2 spike phenomenon for hydrocarbon-based fires is used in?
Signup and view all the answers
Which type of pull box is restricted for use in special applications?
Which type of pull box is restricted for use in special applications?
Signup and view all the answers
A verification method used by addressable systems is?
A verification method used by addressable systems is?
Signup and view all the answers
Fire warning system units for commercial use must be listed in accordance with?
Fire warning system units for commercial use must be listed in accordance with?
Signup and view all the answers
Primary power circuits supplying fire alarm systems must be protected by circuit breakers not larger than?
Primary power circuits supplying fire alarm systems must be protected by circuit breakers not larger than?
Signup and view all the answers
The NFPA 72 Temporal 3 sound pattern for a fire alarm signal is?
The NFPA 72 Temporal 3 sound pattern for a fire alarm signal is?
Signup and view all the answers
At 10 feet, public area audible notification devices must have a minimum rating of?
At 10 feet, public area audible notification devices must have a minimum rating of?
Signup and view all the answers
Which of the following code-authorized signals does not require the approval of the AHJ?
Which of the following code-authorized signals does not require the approval of the AHJ?
Signup and view all the answers
Which of the following conduits or cables cannot be buried?
Which of the following conduits or cables cannot be buried?
Signup and view all the answers
Commercial fire alarm cables that run from floor to floor must be?
Commercial fire alarm cables that run from floor to floor must be?
Signup and view all the answers
Power-limited fire alarm circuit conductors must be separated from non-power-limited fire alarm circuit conductors by at least?
Power-limited fire alarm circuit conductors must be separated from non-power-limited fire alarm circuit conductors by at least?
Signup and view all the answers
How many conductors does a Class B SLC require to reach each device on a circuit?
How many conductors does a Class B SLC require to reach each device on a circuit?
Signup and view all the answers
An SLC that consists of a Class A main trunk with a Class B spur circuit is known as a?
An SLC that consists of a Class A main trunk with a Class B spur circuit is known as a?
Signup and view all the answers
For smoke chamber definition purposes, an archway that extends down from the ceiling is considered a(n)?
For smoke chamber definition purposes, an archway that extends down from the ceiling is considered a(n)?
Signup and view all the answers
The primary function of a duct smoke detector is to?
The primary function of a duct smoke detector is to?
Signup and view all the answers
In a fire alarm system, a visual or audible supervisory signal must be?
In a fire alarm system, a visual or audible supervisory signal must be?
Signup and view all the answers
Study Notes
Fire Alarm Codes and Requirements
- NFPA 70 outlines the requirements for writing and installing fire protective signaling systems.
- NFPA 1 establishes a code for fire authorities to develop safeguards against fire hazards.
Fire Alarm Circuit Classes and Zones
- Class A circuits utilize non-redundant paths to enhance reliability.
- A "Zone" refers to a defined area within a fire alarm system.
Fire Alarm System Types
- A "Multiplex system" is a fire alarm system with zones allowing multiple signals from various sources over one communication line.
- "Air sampling detectors" automatically draw air from the protected area to the detector.
- "Thermoelectric" represents a type of spot detector.
Detectors and Signals
- A fixed-temperature heat detector example is the "fusible link."
- NFPA 72 indicates that duct detectors cannot serve as supervisor devices, which is a misconception; the statement is false.
- The CO2 spike phenomenon, relevant for hydrocarbon fires, is detected using infrared detectors.
Manual Activation and Verification Methods
- Key-operated pull boxes are specialized for certain applications.
- "Wail-and-check" is a verification method utilized by addressable systems.
Fire Alarm System Standards
- Commercial fire warning system units must adhere to UL 864 standards.
- Power circuits supplying fire alarms must use circuit breakers not exceeding 20A.
Alarm Sound Patterns and Notification Standards
- NFPA 72 defines the Temporal 3 sound pattern as three short tones followed by a pause and a repeat.
- Audible notification devices in public areas must achieve a minimum rating of 75 dBa at a distance of 10 feet.
Signal Approval and Wiring Standards
- General signals do not require approval from the Authority Having Jurisdiction (AHJ).
- Plain steel EMT conduits or cables are not suitable for burial.
- Commercial fire alarm cables traveling between floors must be rated for riser use.
Fire Alarm Circuit Specifications
- Power-limited fire alarm circuit conductors must be at least 2 inches apart from non-power-limited conductors.
- A Class B SLC requires two conductors to connect to each device within a circuit.
- A "Hybrid SLC" consists of a Class A main trunk paired with a Class B spur circuit.
Specialized Terms in Fire Alarm Systems
- An archway descending from the ceiling is defined as a "Boundary" for smoke chamber purposes.
- The main function of a duct smoke detector is to deactivate the associated HVAC system.
- Supervisory signals in a fire alarm system must differ from alarm and trouble signals.