Podcast
Questions and Answers
What is the correct order of importance?
What is the correct order of importance?
- Efficiency, Waste, Quality, Safety
- Safety, Quality, Waste, Efficiency
- Quality, Safety, Waste, Efficiency (correct)
- Quality, Safety, Efficiency, Waste
When wiring a new receptacle, what is the silver screw for?
When wiring a new receptacle, what is the silver screw for?
- Hot wire
- Neutral wire
- Ground wire (correct)
- None of the above
What is a likely cause of a pilot light not staying lit on a standing pilot water heater?
What is a likely cause of a pilot light not staying lit on a standing pilot water heater?
- Ignito
- Thermocouple (correct)
- Thermostat
- None of the above
If a positive displacement pump is cavitating, what is a high likely cause?
If a positive displacement pump is cavitating, what is a high likely cause?
What would a meter read if you went from one leg to ground in a 480V 3ph system?
What would a meter read if you went from one leg to ground in a 480V 3ph system?
What is the best type of fire extinguisher to use when putting out a grease fire?
What is the best type of fire extinguisher to use when putting out a grease fire?
What is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload?
What is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload?
In a 100-220 volt three wire circuit, which wire is usually neutral?
In a 100-220 volt three wire circuit, which wire is usually neutral?
What is the total resistance in ohms if 35 resistors of 15 ohms each are connected in a series?
What is the total resistance in ohms if 35 resistors of 15 ohms each are connected in a series?
What is the outside diameter of tubing with an outside diameter of 2” and a wall thickness of 1/16”?
What is the outside diameter of tubing with an outside diameter of 2” and a wall thickness of 1/16”?
Flashcards
Prioritized Order
Prioritized Order
Safety, Quality, Efficiency, then Waste.
Motor Runs Wrong Way
Motor Runs Wrong Way
Ensure correct connections via the wiring diagram, check rotation, and correct wiring.
Receptacle Silver Screw
Receptacle Silver Screw
Neutral wire.
Discrete Input Card
Discrete Input Card
Signup and view all the flashcards
Positive Displacement Pump Cavitation
Positive Displacement Pump Cavitation
Signup and view all the flashcards
480V System Leg to Ground
480V System Leg to Ground
Signup and view all the flashcards
Grease Fire Extinguisher
Grease Fire Extinguisher
Signup and view all the flashcards
Automatic Electrical Switch
Automatic Electrical Switch
Signup and view all the flashcards
Neutral Wire Color
Neutral Wire Color
Signup and view all the flashcards
Thermocouple Operation
Thermocouple Operation
Signup and view all the flashcards
Study Notes
Prioritization of Quality, Safety, Waste, and Efficiency
- Quality, Safety, Waste, and Efficiency should be prioritized in the following order: Safety, Quality, Efficiency, and Waste.
3-Phase Motor Running in the Wrong Direction
- If a 3-phase motor is running in the wrong direction, the steps to be taken are:
- Check the motor wiring diagram to ensure correct connections.
- Verify the motor rotation direction using a multimeter or other test equipment.
- Correct the wiring connections to match the motor wiring diagram.
Wiring a New Receptacle
- The silver screw on a receptacle is for: Neutral wire.
Troubleshooting a Standing Pilot Water Heater
- If the pilot light on a standing pilot water heater won't stay lit, the possible cause is: Thermocouple.
Series Resistance Calculation
- 35 resistors of 15 ohms each connected in a series have a total resistance of: 525 ohms.
Discrete Input Card vs. Analog Card
- A discrete input card is used for digital signals, while an analog card is used for analog signals.
Positive Displacement Pump Cavitation
- If a positive displacement pump is cavitating, a high likely cause is: Air in the pump.
3-Phase System Voltage Measurement
- In a 480V 3-phase system, the meter reading from one leg to ground would be: 277V.
Grease Fire Extinguisher
- The best type of fire extinguisher to use for putting out a grease fire is: Baking soda.
Automatically Operated Electrical Switch
- An automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload is called: Circuit breaker.
Painting a Room
- The number of gallons of paint required to paint the walls of a 7'6" x 9' room with an 8' ceiling height is: ½ gallon.
Neutral Wire Color
- In a 100-220 volt three-wire circuit, the neutral wire is usually: White.
Tubing Dimensions
- Tubing with an outside diameter of 2" and a wall thickness of 1/16" has an inside diameter of: 1 ¾".
Testing Elements on a Forced Air Electric Heater
- The best way to test if the elements on a forced air electric heater work or come on properly is by using: Continuity tester.
Thermocouple Operation
- The thermocouple on a gas heater operates: Gas valve.
Electrical Fire Extinguisher
- The correct substance to use in putting out an electrical fire is: Co2 or Baking soda.
Studying That Suits You