DIY Skills Test
48 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What should be avoided when installing carriage bolts into the square hole?

  • Leveling the J-arm with the torpedo level
  • Installing washers between the carriage bolt and the square hole (correct)
  • Tightening rear lock bolts incrementally
  • Ensuring the carriage bolts sit and lock into place without spinning
  • What should be used to locate the rafter beam when penetrating an asphalt shingle roof?

  • A saw
  • A drill
  • A hammer
  • A stud finder (correct)
  • Why should an impact wrench not be used to tighten the hardware?

  • It will make it easier to adjust or remove the mount assembly
  • It will result in the bolts stripping (correct)
  • It will ensure the mount is tightened accurately from both ends
  • It will help keep the arm in place through the leveling process
  • What should be done to limit trips up the roof when using penetrating mounts on asphalt shingle roofs?

    <p>Avoid traveling repeatedly across the roof</p> Signup and view all the answers

    What is the maximum length allowed for extension arms in this installation process?

    <p>19 inches</p> Signup and view all the answers

    How many self-tapping screws should be installed per added extension arm?

    <p>Three</p> Signup and view all the answers

    What is the recommended pattern for installing self-tapping screws to maintain mast stability?

    <p>In a triangular pattern</p> Signup and view all the answers

    What is the recommended tool to use for sinking self-tapping screws?

    <p>Impact drill</p> Signup and view all the answers

    Why should EMT extension arms not be used in Seed radio mounts?

    <p>Seed radios are too large</p> Signup and view all the answers

    What is the protocol for mounting equipment on a customer's roof?

    <p>Place the mount as high on the roof as possible while achieving the best LOS</p> Signup and view all the answers

    How many total photos should be uploaded into SalesForce per failed AP?

    <p>8</p> Signup and view all the answers

    What should be included in the marked up photos of the failed AP(s)?

    <p>Markers such as arrows, circles, and text that clearly show the location of where the AP(s) are located</p> Signup and view all the answers

    What should be done if an additional AP is needed for Leaf installation?

    <p>Work with your manager to coordinate your schedule or another available technician to add the additional AP</p> Signup and view all the answers

    How many zoomed in photos from the current Leaf home to the Super Anchor home(s) are required for the picture requirements?

    <p>2</p> Signup and view all the answers

    What is the purpose of using roof sealant mastic tape during installation?

    <p>To prevent water leakage through the mounting plate</p> Signup and view all the answers

    What type of roofs require non-penetration peak mounts when installing box mounts?

    <p>Membrane, metal, and wood shingle roofs</p> Signup and view all the answers

    How many skids are required for a 2-skid box mount installation?

    <p>2</p> Signup and view all the answers

    What is the purpose of using outdoor rated floor mats during box mount installations?

    <p>To prevent roof damage to the customer's home</p> Signup and view all the answers

    What is the maximum number of skid extensions that can be added to a 2-skid mount?

    <p>3</p> Signup and view all the answers

    What is the purpose of LOS Survey Technicians in the installation process?

    <p>To confirm LOS prior to installation</p> Signup and view all the answers

    What should technicians do if there are any installation variations required?

    <p>Consult with their direct supervisor</p> Signup and view all the answers

    What is the recommended approach for validating LOS for a 2-Man build team?

    <p>Each technician should be on a separate roof</p> Signup and view all the answers

    What should technicians do if they encounter procedures that are contrary to their current understanding?

    <p>Consult with their direct supervisor</p> Signup and view all the answers

    What should technicians do if they encounter local variations during installation?

    <p>Consult with their direct supervisor</p> Signup and view all the answers

    What is the total number of photos that should be uploaded into SalesForce for each failed link?

    <p>16</p> Signup and view all the answers

    When should a single person build be scheduled?

    <p>When the connecting sites are less than 200 meters apart</p> Signup and view all the answers

    What should the marked up photos include to clearly show the location of the other site and/or the obstruction?

    <p>Arrows, circles, and text</p> Signup and view all the answers

    What should technicians do once a failed LOS has been deemed?

    <p>Capture photos of the failed path and report it to their manager</p> Signup and view all the answers

    How many total photos should be uploaded into SalesForce for each failed LOS requirement example, such as the Leaf LOS issue procedure?

    <p>8</p> Signup and view all the answers

    What is the recommended number of cinder blocks to be placed on each sled mount for weight support?

    <p>4-8 cinder blocks</p> Signup and view all the answers

    What should be placed under the sled to prevent potential weight damage to the roof's membrane when using third-party non-pen sled mounts?

    <p>Protective mats</p> Signup and view all the answers

    What size conduit cut-to-length pipe extension can be used to obtain higher radio position?

    <p>1-½’’ EMT conduit</p> Signup and view all the answers

    What should be done before installing the extension pipe into the top of the J-arm?

    <p>Clear the inside of the J-arm on the existing mount from any obstruction</p> Signup and view all the answers

    What tool is needed to drill the tappers into the J-arm and extension arm when installing extension pipes?

    <p>5/16th socket/nut driver</p> Signup and view all the answers

    What should technicians use to level each J-Arm when installing a mount?

    <p>A torpedo level provided in the technician tool kit</p> Signup and view all the answers

    How many visits are required after the initial installation of two mounts?

    <p>Three visits</p> Signup and view all the answers

    What should be avoided when placing mounts?

    <p>Close proximity to roof vents</p> Signup and view all the answers

    What is the consequence of over tightening the bolts when installing a tile mount?

    <p>The metal frame of the mount will bend</p> Signup and view all the answers

    What should technicians use to avoid mount and support arm movement?

    <p>Properly tighten all hardware</p> Signup and view all the answers

    What should be done to ensure proper installation of the MBU lid covers?

    <p>Modify the bottom teeth of the lid covers with a pair of snips</p> Signup and view all the answers

    What is the purpose of creating drip loops on each cable on the outside penetration point?

    <p>To avoid any possible water intrusion</p> Signup and view all the answers

    What should be done to avoid water entry in the UPS enclosure?

    <p>Close the lid with the gasket properly in place</p> Signup and view all the answers

    What should be done to ensure that the carriage bolts lock in place during installation of support arms?

    <p>Insert the carriage bolts in the direction of the square hole</p> Signup and view all the answers

    What is the procedure to follow when an LOS issue is found during an LOS site survey on any infrastructure site?

    <p>Contact your manager and submit a workflow to the planning team</p> Signup and view all the answers

    What should a technician do if they are assigned a build by themselves that is over 200 meters?

    <p>Consult with the manager to arrange another technician or supervisor assistance</p> Signup and view all the answers

    What is the requirement for capturing LOS photos for a 2-man team?

    <p>(4) LOS photos from each side, or (8) total photos captured</p> Signup and view all the answers

    When should a technician mark the LOS link issue in the Techview Aiming Map?

    <p>Once a link has been determined as failed LOS</p> Signup and view all the answers

    What should a technician do if there is an LOS issue on a Fiber site?

    <p>Verify no LOS to all related Anchor sites using the azimuths provided in the Techview Aiming Map</p> Signup and view all the answers

    More Like This

    Roof Design Types
    8 questions

    Roof Design Types

    SofterStrontium avatar
    SofterStrontium
    Firefighting: Roof Support Systems
    5 questions
    Firefighter Roof Support Systems
    10 questions
    Roof & Ceiling Structures Flashcards
    31 questions
    Use Quizgecko on...
    Browser
    Browser