DC Seal Oil Pump Operation

WholesomeMaroon avatar
WholesomeMaroon
·
·
Download

Start Quiz

Study Flashcards

20 Questions

What is the objective of having procedures for responding to adverse conditions in a plant?

To provide guidelines for dealing with common equipment failures

Why must plant operators be well versed in plant blackout procedures?

To understand how power failures affect plant equipment

What is an important consideration for operators during an electrical power failure?

Knowing how to restart equipment after power is restored

Why is it important for operators to know how to manually start a standby generator?

To have a backup plan if the generator fails to start automatically

What is the purpose of the DC seal oil pump mentioned in the text?

To keep hydrogen coolant inside large alternators

What could be a cause of loss of water level in the boiler?

Failure of the boiler feedwater pump

What should be done if a condensate transfer pump fails, resulting in low deaerator level?

Start the standby boiler feedwater pump

What action should be taken if a leak is suspected in the boiler?

Close the pilot and main test firing valves

What should be done if the boiler water level is below the lowest visible part of the gauge glass?

Shut the boiler down, let it cool slowly, and do not add water to restore the water level

What should be done if there is an inadequate pilot flame during the ignition period?

Contact a certified burner technician or Class A gas fitter to adjust the pilot to manufacturer specifications

What causes an unstable main flame in a boiler?

Excessive fuel pressure, inadequate fuel pressure, or excessive combustion air

What should be done if there is a flame failure during boiler operation?

Shut the pilot and main test firing valves and investigate the cause of failure

What happens to valves when a power failure occurs in a power plant?

They go to a fail-safe position, some failing open and others failing shut

What should the operator do immediately on power failure if the fire in the boiler is not out?

Ensure that the main and pilot test firing valves are closed

What does an Emergency Power Supply System (EPSS) in a power plant provide?

Long-term power to essential loads with automatic transfer switches

What is the purpose of a Uninterruptible Power Supply (UPS) in a power plant?

Maintains power to critical equipment at all times through a system of batteries and automatic transfer switches

What should be done if the fuel oil pressure remains inadequate after changing the fuel oil strainer?

Switch to the standby fuel oil pump

What can cause poor quality flames in air or steam-atomized burners?

Inadequate atomizing medium pressure

What should be done if the combustion air proving switch fails to shut down the burner when the forced draft fan fails?

Immediately shut the main and pilot test firing valves

What may be the problem if all normal operating parameters are met but the boiler fails to light off or has repeated flame failures?

Defective programmed combustion control or flame amplifier

Test your knowledge about the operation of DC seal oil pumps and their role in preventing hydrogen coolant leaks and explosion hazards during power failures.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

DC Generator Quiz
5 questions

DC Generator Quiz

NobleChrysocolla avatar
NobleChrysocolla
DC Biasing for JFET and MOSFET
18 questions
Power Electronics: DC-DC Converters
30 questions
DC Machine Characteristics Experiment
18 questions
Use Quizgecko on...
Browser
Browser