What is the objective of having procedures for responding to adverse conditions in a plant?

  • To eliminate the need for manual control by operators
  • To ensure continuous production without interruptions
  • To provide guidelines for dealing with common equipment failures (correct)
  • To reduce the workload of plant personnel
  • Why must plant operators be well versed in plant blackout procedures?

  • To understand how power failures affect plant equipment (correct)
  • To avoid any manual intervention during power failures
  • To minimize the impact of power failures on production
  • To eliminate the need for standby power and generators
  • What is an important consideration for operators during an electrical power failure?

  • Identifying the positions of various control valves for future reference
  • Knowing how to restart equipment after power is restored (correct)
  • Knowing which equipment is fed by uninterrupted power
  • Understanding the impact of power failures on standby power systems
  • Why is it important for operators to know how to manually start a standby generator?

    <p>To have a backup plan if the generator fails to start automatically</p> Signup and view all the answers

    What is the purpose of the DC seal oil pump mentioned in the text?

    <p>To keep hydrogen coolant inside large alternators</p> Signup and view all the answers

    What could be a cause of loss of water level in the boiler?

    <p>Failure of the boiler feedwater pump</p> Signup and view all the answers

    What should be done if a condensate transfer pump fails, resulting in low deaerator level?

    <p>Start the standby boiler feedwater pump</p> Signup and view all the answers

    What action should be taken if a leak is suspected in the boiler?

    <p>Close the pilot and main test firing valves</p> Signup and view all the answers

    What should be done if the boiler water level is below the lowest visible part of the gauge glass?

    <p>Shut the boiler down, let it cool slowly, and do not add water to restore the water level</p> Signup and view all the answers

    What should be done if there is an inadequate pilot flame during the ignition period?

    <p>Contact a certified burner technician or Class A gas fitter to adjust the pilot to manufacturer specifications</p> Signup and view all the answers

    What causes an unstable main flame in a boiler?

    <p>Excessive fuel pressure, inadequate fuel pressure, or excessive combustion air</p> Signup and view all the answers

    What should be done if there is a flame failure during boiler operation?

    <p>Shut the pilot and main test firing valves and investigate the cause of failure</p> Signup and view all the answers

    What happens to valves when a power failure occurs in a power plant?

    <p>They go to a fail-safe position, some failing open and others failing shut</p> Signup and view all the answers

    What should the operator do immediately on power failure if the fire in the boiler is not out?

    <p>Ensure that the main and pilot test firing valves are closed</p> Signup and view all the answers

    What does an Emergency Power Supply System (EPSS) in a power plant provide?

    <p>Long-term power to essential loads with automatic transfer switches</p> Signup and view all the answers

    What is the purpose of a Uninterruptible Power Supply (UPS) in a power plant?

    <p>Maintains power to critical equipment at all times through a system of batteries and automatic transfer switches</p> Signup and view all the answers

    What should be done if the fuel oil pressure remains inadequate after changing the fuel oil strainer?

    <p>Switch to the standby fuel oil pump</p> Signup and view all the answers

    What can cause poor quality flames in air or steam-atomized burners?

    <p>Inadequate atomizing medium pressure</p> Signup and view all the answers

    What should be done if the combustion air proving switch fails to shut down the burner when the forced draft fan fails?

    <p>Immediately shut the main and pilot test firing valves</p> Signup and view all the answers

    What may be the problem if all normal operating parameters are met but the boiler fails to light off or has repeated flame failures?

    <p>Defective programmed combustion control or flame amplifier</p> Signup and view all the answers