DC Seal Oil Pump and Power Failure
30 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What should operators be well versed in to respond correctly to adverse conditions?

  • Plant watering procedures
  • Plant blackout procedures (correct)
  • Plant pruning procedures
  • Plant fertilization procedures
  • What is one of the considerations for dealing with electrical power failures?

  • The size of the control room desk
  • The number of office chairs in the control room
  • The positions in which various control valves fail (open, shut, or last position) (correct)
  • The color of the control room walls
  • What should operators know about equipment fed by standby power?

  • What equipment is fed by solar power, and what is not
  • What equipment is fed by hydroelectric power, and what is not
  • What equipment is fed by standby power, and what is not (correct)
  • What equipment is fed by wind power, and what is not
  • In the event of a standby generator failing to start automatically, what should operators know how to do?

    <p>Manually start a standby generator</p> Signup and view all the answers

    What should operators be knowledgeable about to restart equipment after power is restored?

    <p>The sequence for starting equipment after power is restored</p> Signup and view all the answers

    What should plant operators be able to do if an automatic transfer switch fails to operate automatically?

    <p>Manually operate an automatic transfer switch</p> Signup and view all the answers

    What is the primary purpose of an Emergency Power Supply System (EPSS) in a power plant?

    <p>To start automatically and supply power to critical equipment during a power failure</p> Signup and view all the answers

    What is the function of an Uninterruptible Power Supply (UPS) in a power plant?

    <p>To maintain power to critical equipment at all times through a system of batteries</p> Signup and view all the answers

    What happens to valves when there is a loss of power in a power plant?

    <p>They fail shut or closed, blocking flow</p> Signup and view all the answers

    What is the appropriate action for an operator when a power failure occurs in a plant with no backup power?

    <p>Monitor the boiler as it cools down and perform tasks to put the plant in a safe state</p> Signup and view all the answers

    What is one of the challenges of firing solid fuel during a power failure?

    <p>The fuel in the furnace can continue to burn and lower the boiler water level</p> Signup and view all the answers

    What is the purpose of banking the fire in a boiler during a power failure?

    <p>To prevent unattended light-off when power is restored</p> Signup and view all the answers

    What should be done if the fuel oil pressure remains low after changing the fuel oil strainer?

    <p>Switch to the standby fuel oil pump and check the fuel supply pressure</p> Signup and view all the answers

    What is a common cause of poor quality flames in air or steam-atomized burners?

    <p>Inadequate atomizing medium pressure</p> Signup and view all the answers

    What can cause the flame safeguard control to trip the burner off?

    <p>Failure of flame detection and flame safeguard controls</p> Signup and view all the answers

    What should be done if an FD fan fails, and the combustion air proving switch does not shut down the burner?

    <p>Immediately shut the main and pilot test firing valves</p> Signup and view all the answers

    What should be done after repairs are complete for an FD fan failure?

    <p>Thoroughly purge the furnace prior to beginning a normal restart</p> Signup and view all the answers

    What is recommended to sweep carbon monoxide and unburned fuel from the furnace after shutting down an FD fan?

    <p>Allow air to enter the furnace through the fan damper when the furnace is cooler</p> Signup and view all the answers

    What should be done when the boiler water level is below the lowest visible part of the gauge glass?

    <p>Shut the boiler down and let it cool slowly</p> Signup and view all the answers

    What can cause excessive fuel pressure in a boiler?

    <p>Inadequate fuel pressure regulator</p> Signup and view all the answers

    What may result from an inadequate pilot flame during the ignition period?

    <p>Main flame instability</p> Signup and view all the answers

    What should be done if the boiler water level is above the highest visible part of the gauge glass?

    <p>Lower the boiler water level using blowoff valves</p> Signup and view all the answers

    What should be done if a flame failure occurs in a boiler?

    <p>Shut the test firing valves and isolate the boiler</p> Signup and view all the answers

    What should be done when the boiler water level is outside of the visible portion of the gauge glass?

    <p>Blow down the gauge glass to reveal the water level</p> Signup and view all the answers

    What is the purpose of the DC seal oil pump mentioned in the text?

    <p>To start on a power failure and run until the hydrogen can be vented</p> Signup and view all the answers

    What could be a cause of a loss of water level in the boiler?

    <p>Overheating due to excessive waterside scale accumulation</p> Signup and view all the answers

    What action should be taken if the feedwater control valve is suspected to be closed?

    <p>Remove the feedwater control valve from service and repair promptly</p> Signup and view all the answers

    What could be the consequence of a condensate transfer pump failing?

    <p>Boiler feedwater pump damage and low boiler water level</p> Signup and view all the answers

    How can a quick scan of blowdown and blowoff lines reveal problems with the boiler?

    <p>By checking the temperature with a handheld infrared thermometer</p> Signup and view all the answers

    What is the recommended action if a leak is suspected in the boiler?

    <p>Shut down the boilers until the cause of the low deaerator level is determined and corrected</p> Signup and view all the answers