Podcast
Questions and Answers
What is the minimum distance that a portable ladder needs to extend above the upper ledge?
What is the minimum distance that a portable ladder needs to extend above the upper ledge?
When should a rope being used on a scaffold be replaced?
When should a rope being used on a scaffold be replaced?
What must abrasive wheels used for grinding be equipped with?
What must abrasive wheels used for grinding be equipped with?
Who has the authority to change or adjust the shoring method of an excavation?
Who has the authority to change or adjust the shoring method of an excavation?
Signup and view all the answers
How many feet must an LP Gas container with 650 lbs be stored away from the nearest building?
How many feet must an LP Gas container with 650 lbs be stored away from the nearest building?
Signup and view all the answers
What is the maximum number of gallons of flammable liquid that can be stored in a room without an approved container?
What is the maximum number of gallons of flammable liquid that can be stored in a room without an approved container?
Signup and view all the answers
Who is permitted to work under a suspended load when erecting steel?
Who is permitted to work under a suspended load when erecting steel?
Signup and view all the answers
What should all hand-held powered tools such as drills and grinders be equipped with?
What should all hand-held powered tools such as drills and grinders be equipped with?
Signup and view all the answers
What is the maximum height that all ladder jack scaffolds can exceed without violation?
What is the maximum height that all ladder jack scaffolds can exceed without violation?
Signup and view all the answers
What protection must be provided to each employee on a single-point or two-point adjustable suspension scaffold?
What protection must be provided to each employee on a single-point or two-point adjustable suspension scaffold?
Signup and view all the answers
How far must excavated or other materials be stored from the edge of the excavation?
How far must excavated or other materials be stored from the edge of the excavation?
Signup and view all the answers
What must electric hand tools be equipped with to ensure safety?
What must electric hand tools be equipped with to ensure safety?
Signup and view all the answers
What should an emergency service plan address when a project becomes larger and more complex?
What should an emergency service plan address when a project becomes larger and more complex?
Signup and view all the answers
What is the required method for stacking bag materials on the job site?
What is the required method for stacking bag materials on the job site?
Signup and view all the answers
How frequently should cranes in regular service be inspected for leakage in their systems?
How frequently should cranes in regular service be inspected for leakage in their systems?
Signup and view all the answers
How far must the distance be to the lower level for employees constructing a leading edge to require fall protection?
How far must the distance be to the lower level for employees constructing a leading edge to require fall protection?
Signup and view all the answers
At what depth must guardrail systems, fences, or barricades be used to protect employees at the edge of an excavation?
At what depth must guardrail systems, fences, or barricades be used to protect employees at the edge of an excavation?
Signup and view all the answers
What is the minimum distance stored materials can be from an exterior wall that does not extend above the top of the material?
What is the minimum distance stored materials can be from an exterior wall that does not extend above the top of the material?
Signup and view all the answers
How often should the contents of a first aid kit be checked by the employer?
How often should the contents of a first aid kit be checked by the employer?
Signup and view all the answers
What type of control does momentary contact control represent?
What type of control does momentary contact control represent?
Signup and view all the answers
What type of guards must portable, power-driven circular saws be equipped with?
What type of guards must portable, power-driven circular saws be equipped with?
Signup and view all the answers
What is the minimum clearance between scaffolds and insulated power lines with less than 300 volts?
What is the minimum clearance between scaffolds and insulated power lines with less than 300 volts?
Signup and view all the answers
In which Subpart can the OSHA requirements for formwork be found?
In which Subpart can the OSHA requirements for formwork be found?
Signup and view all the answers
How far must warning lines be flagged with high-visibility material from the edge of the roof?
How far must warning lines be flagged with high-visibility material from the edge of the roof?
Signup and view all the answers
What is the minimum distance without protected sides or edges that requires a fall protection system?
What is the minimum distance without protected sides or edges that requires a fall protection system?
Signup and view all the answers
An oxygen enriched atmosphere contains more than what percentage of oxygen by volume?
An oxygen enriched atmosphere contains more than what percentage of oxygen by volume?
Signup and view all the answers
What is the minimum working clearance under an electric panel under 150 Volts?
What is the minimum working clearance under an electric panel under 150 Volts?
Signup and view all the answers
Which type of eye protection is unsuitable for employees who wear corrective lenses?
Which type of eye protection is unsuitable for employees who wear corrective lenses?
Signup and view all the answers
When employees work in trenches that are 4 feet or deeper, how far can egress be located?
When employees work in trenches that are 4 feet or deeper, how far can egress be located?
Signup and view all the answers
For hook-on and attachable ladders on a scaffold over 35 feet high, what is the maximum vertical interval for rest platforms?
For hook-on and attachable ladders on a scaffold over 35 feet high, what is the maximum vertical interval for rest platforms?
Signup and view all the answers
What should be the first item tested for when checking for atmospheric hazards in a confined space?
What should be the first item tested for when checking for atmospheric hazards in a confined space?
Signup and view all the answers
What is the maximum allowable distance for a ladder, ramp, or stairway from the work area in trenches?
What is the maximum allowable distance for a ladder, ramp, or stairway from the work area in trenches?
Signup and view all the answers
What is the minimum distance a safety net must extend outward when the vertical distance to the level below is over 10 feet?
What is the minimum distance a safety net must extend outward when the vertical distance to the level below is over 10 feet?
Signup and view all the answers
What requirement exists for wire ropes on catenary scaffolds?
What requirement exists for wire ropes on catenary scaffolds?
Signup and view all the answers
What must be avoided between potable and nonpotable water systems?
What must be avoided between potable and nonpotable water systems?
Signup and view all the answers
How much more protective is a full facepiece mask air-purifying respirator compared to a half mask?
How much more protective is a full facepiece mask air-purifying respirator compared to a half mask?
Signup and view all the answers
If a system is rated for 240v, how many leads are used as circuit conductors?
If a system is rated for 240v, how many leads are used as circuit conductors?
Signup and view all the answers
When can compressed air be used to clean dust from equipment?
When can compressed air be used to clean dust from equipment?
Signup and view all the answers
What is the maximum distance that flammable liquids can be stored from a building?
What is the maximum distance that flammable liquids can be stored from a building?
Signup and view all the answers
What is the minimum required dead weight that an anchorage or structural member must support with a lifeline attached?
What is the minimum required dead weight that an anchorage or structural member must support with a lifeline attached?
Signup and view all the answers
What is the minimum support capability required for anchorages used for personal fall arrest equipment?
What is the minimum support capability required for anchorages used for personal fall arrest equipment?
Signup and view all the answers
What is the maximum travel distance to the nearest fire extinguisher in a protected area of 3,000 square feet?
What is the maximum travel distance to the nearest fire extinguisher in a protected area of 3,000 square feet?
Signup and view all the answers
What is the required side clearance for a temporary radiant type heater?
What is the required side clearance for a temporary radiant type heater?
Signup and view all the answers
What is the minimum rear clearance for a temporary circulating room heating device?
What is the minimum rear clearance for a temporary circulating room heating device?
Signup and view all the answers
What is the minimum distance that a scaffold platform can be placed from the face for plastering and lathing operations?
What is the minimum distance that a scaffold platform can be placed from the face for plastering and lathing operations?
Signup and view all the answers
At what height is a guard rail required for cross over excavation?
At what height is a guard rail required for cross over excavation?
Signup and view all the answers
What percentage of oxygen by volume defines an oxygen-deficient atmosphere?
What percentage of oxygen by volume defines an oxygen-deficient atmosphere?
Signup and view all the answers
What is the minimum width of driveways between and around combustible storage piles?
What is the minimum width of driveways between and around combustible storage piles?
Signup and view all the answers
Combustible materials can be piled a maximum of?
Combustible materials can be piled a maximum of?
Signup and view all the answers
Open yard storage of portable fire extinguishing equipment shall be placed so the maximum travel distance
to the nearest unit shall not exceed?
Open yard storage of portable fire extinguishing equipment shall be placed so the maximum travel distance to the nearest unit shall not exceed?
Signup and view all the answers
Study Notes
Ladder Safety
- The minimum distance a ladder must extend above the upper ledge is 3 feet.
- OSHA: Construction Industry Regulations - 1926.1053(b)(1)
Rope Safety on Scaffolds
- A rope used on a scaffold needs replacing when there are six randomly distributed broken wires in one rope lay or three broken wires in one strand in a rope lay.
- OSHA: Construction Industry Regulations - 1926.451(d)(10)(iii).
Abrasive Wheel Safety
- Abrasive wheels must be equipped with safety guards or protection hoods.
- OSHA: Construction Industry Regulations - 1926.303(c)(1)
Excavation Shoring Authority
- The excavator has the authority to change or adjust the shoring method of an excavation.
- OSHA: Construction Industry Regulations - 1926.652(c)
LP Gas Container Storage
- An LP Gas container containing 650 lbs. must be stored 10 feet from the nearest building.
- OSHA: Construction Industry Regulations - 1926.153(k) Table F-3
Flammable Liquid Storage
- The maximum allowable gallons of flammable liquid that can be stored in a room (and not in an approved container) is 25 gallons.
- OSHA: Construction Industry Regulations - 1926.152(b)(1)
Suspended Loads during Steel Erection
- In steel erection, only employees hooking the load are permitted to work under a suspended load.
- OSHA: Construction Industry Regulations - 1926.753(d)
Powered Tool Equipment
- Powered hand tools like drills, tappers, fasteners, and grinders, with wheels larger than 2 inches in diameter, must have a momentary contact "on-off" control, and may have a lock-on control.
- OSHA: Construction Industry Regulations - 1926.300(d)(2)
Ladder Jack Scaffolds
- Ladder jack scaffolds have a maximum height of 20 feet above the floor or ground.
- OSHA: Construction Industry Regulations - 1926.452(k)(1)
Portable Power Saws
- Portable, power-driven circular saws must have guards above and below the base plate.
- OSHA: Construction Industry Regulations - 1926.304(d)
Emergency Service Plans
- Project plans for emergency service must include evacuation procedures when the project becomes complex.
- OSHA: Construction Industry Regulations - 1926.35(d)
Suspension Scaffold Protection
- Employees on single-point or two-point adjustable suspension scaffolds require both a personal fall arrest system and a guardrail system.
- OSHA: Construction Industry Regulations - 1926.451(g)(1)(ii)
Leading Edge Protection
- Each worker erecting a leading edge shall be protected from falling when the distance to the lower level is 6 feet or more.
- OSHA: Construction Industry Regulations - 1926.501(b)(2)(i)
Grounded or Double Insulated Tools
- Electric hand tools must be either grounded or double insulated.
- OSHA: Construction Industry Regulations - 1926.302(a)(1)
Excavation Protection
- Workers at excavation edges need protection (guardrails, fences, or barricades) when the excavation depth is 6 feet or more, or when plant growth or barriers obstruct visibility.
- OSHA: Construction Industry Regulations - 1926.501(b)(Z)(i).
Excavation Material Storage
- Excavated or other materials must be stored at least 2 feet from excavation edges.
- OSHA: Construction Industry Regulations - 1926.651(j)(2).
Bag Material Storage Requirements
- Bag materials on job sites need to be stacked by stepping back the layers and cross-keying every 10 bags.
- OSHA: Construction Industry Regulations - 1926.250(b)(4)
Crane Inspections
- Cranes in regular service must be inspected each shift for leakage in air or hydraulic systems.
- OSHA: Construction Industry Regulations - 1926.1412(d)(1)(iii).
Material Storage Inside Construction Buildings
- Materials stored inside construction buildings cannot be placed within 10 feet of exterior walls that do not extend above the top of the materials.
- OSHA: Construction Industry Regulations - 1926.250(b)(1)
First Aid Kit Maintenance
- First aid kits must have contents in a weatherproof container with sealed packages and should be checked weekly by employers.
- OSHA: Construction Industry Regulations - 1926.50(d)(2).
Scaffold and Power Line Clearance
- The minimum clearance between scaffolds and insulated power lines with less than 300 volts must be 3 feet.
- OSHA: Construction Industry Regulations - 1926.451(f)(6)
Formwork Requirements
- OSHA requirements for formwork are in Subpart Q.
- OSHA: Construction Industry Regulations - 1926.703(a).
Warning Lines on Roofs
- Warning lines on roofs need to be flagged with high-visibility material a maximum of 6 feet distance from the edge of the roof.
- OSHA: Construction Industry Regulations - 1926.502(f)(2)(i).
Excavation Kickout Safety
- A "kickout" in an excavation means a cross brace in a shoring system has failed.
- OSHA: Construction Industry Regulations - 1926.650(b) Definitions
Minimum Working Clearance for Electrical Panels
- The minimum working clearance for electrical panels under 150 volts is 3 square feet
- OSHA: Construction Industry Regulations - 1926.403 Table K-1
Eye Protection for Corrective Lens Wearers
- Protective goggles with generic magnification lenses are NOT suitable for employees who wear corrective lenses (glasses).
- OSHA: Construction Industry Regulations - 1926.102(a)(3)
Trench Egress Requirements
- When employees work in trenches 4 feet deep or more, the means of egress (stairway, ladder, ramp etc.) requires maximum travel laterally shall be no more than 25 feet.
- OSHA: Construction Industry Regulations - 1926.651(c)(2)
Scaffold Ladder Rest Platforms
- When using hook-on and attachable ladders on scaffolds over 35 feet in height, rest platforms must have maximum vertical intervals of 35 feet at maximum.
- OSHA: Construction Industry Regulations - 1926.451(e)(2)(iii)
Confined Space Testing
- When testing for atmospheric hazards in a confined space, the first item to test for is oxygen.
- OSHA: Construction Industry Regulations - 1926.1203(e)(2)(iii).
Safety Net Extension Distances
- When the distance from a working level to the level below is over 10 feet, safety nets must extend outward from the outermost projection a minimum of 13 feet.
- OSHA: Construction Industry Regulations - 1926.502(c)(2)
Wire Rope on Catenary Scaffolds
- Wire ropes on catenary scaffolds must be continuous and not connected with splices between anchors.
- OSHA: Construction Industry Regulations - 1926.452(r)(4)
Water and Non-potable Water System Separation
- There must be no cross-connection between systems furnishing potable water and non-potable water.
- OSHA: Construction Industry Regulations - 1926.51(b)(2)
Face Piece Air-Purifying Respirator Protection Factor
- A full facepiece mask air-purifying respirator has a protection factor five times greater than a half mask.
- OSHA: Construction Industry Regulations - 1910.134(d)(3)(i)(A) Table 1
Electrical Conductor Lead Requirements
- If an electrical system is rated for 240V, then four leads are required as circuit conductors
- OSHA: Construction Industry Regulations - 1926.404(f)(1)(iv)
Compressed Air for Cleaning Equipment
- OSHA regulations do not expressly state when compressed air can be used for cleaning equipment.
Portable Fire Extinguisher Requirements
- For every 3,000 square feet of protected building area, a portable fire extinguisher rated at least 2A must be available and accessible within a 100-foot distance.
- OSHA: Construction Industry Regulations - 1926.150(c)(1)(i).
Scaffold Platform Placement for Plastering/Lathing
- Scaffold platforms for plastering and lathing operations must be placed no further than 18 inches from the face of the work.
- OSHA: Construction Industry Regulations - 1926.451(b)(3)(ii)
Flammable Liquid Storage Distance from Buildings and piles
- Flammable liquids should be stored at least 20 feet from a building in piles or groups of containers.
- OSHA: Construction Industry Regulations - 1926.152(c)(1)
Temporary Heating Device Rear Clearance
- Temporary circulating room heating devices need at least 12 inches of rear clearance.
- OSHA: Construction Industry Regulations - 1926.154(b)(2) Table F-4
Temporary Radiant Room Heater Side Clearance
- Temporary radiant room heating devices need at least 36 inches of side clearance.
- OSHA: Construction Industry Regulations - 1926.154 (Table F-4)
Anchorage Minimum Dead Weight
- Anchorages or structural members with attached lifelines must be able to support a minimum dead weight of 5,400 lbs.
- OSHA: Construction Industry Regulations - 1926.104(b)
Combustible Storage Pile Driveway Width
- Driveways between and around combustible storage piles must be at least 15 feet wide.
- OSHA: Construction Industry Regulations - 1926.151(c)(2)
Combustible Material Pile Height
- Combustible materials can be piled to a maximum height of 20 feet.
- OSHA: Construction Industry Regulations - 1926.151(c)(1)
Open Yard Storage Distance
- Open yard storage of portable fire extinguishing equipment must have a maximum travel distance to the nearest unit of 100 feet.
- OSHA: Construction Industry Regulations - 1926.151(c)(6)
Stairway/Ladder Provision for Elevation Change
- Stairways or ladders must be provided at all points of access where there is a break in elevation of 19 inches or more.
- OSHA: Construction Industry Regulations - 1926.1051(a)
Excavation Inspection Frequency
- Excavation sites must be inspected daily, and after every rainstorm.
- OSHA: Construction Industry Regulations - 1926.651(k)(1)
Fire Door Clearance
- A 24-inch clearance must be maintained around the travel path of fire doors; any barricade needs no clearance.
- OSHA: Construction Industry Regulations - 1926.151(d)(Z)
Fire Door Storage Restriction
- Materials shall not be stored within 36 inches of a fire door opening.
- OSHA: Construction Industry Regulations - 1926.151(d)(Z)
Oxygen Cylinder Storage Distance
- Oxygen cylinders should be stored at least 20 feet from fuel-gas cylinders or combustible materials.
- OSHA: Construction Industry Regulations - 1926.350(a)(10)
Excavation Slope for Type B Soil
- The maximum allowable slope for an 18' deep Type B soil excavation is 1:1.
- OSHA: Construction Industry Regulations - Subpart P Appendix B Table B-1
Soil Type for Vertical Excavation Sides
- Stable Rock allows for excavation with vertical 90-degree sides that remain intact upon exposure.
- OSHA: Construction Industry Regulations - Subpart P Appendix B Table B-1
Electrical Panel Workspace Minimum Width
- The minimum width of a workspace in front of an electrical panel box is 30 inches.
- OSHA: Construction Industry Regulations - 1926.403(i)(1)(i)
Wire Rope Replacement Criteria
- Six randomly distributed broken wires in a rope lay or three in a strand, require replacing the rope.
- OSHA: Construction Industry Regulations - 1926.1413(a)(4)(ii)(B).
Damaged Wire Rope Length Before Replacement
- If a 3/4" wire rope is used as a sling, up to 6 inches of damage can occur before a replacement is required
- OSHA: Construction Industry Regulations - 1926.251(c)(4)(iv)