Podcast
Questions and Answers
What is used as a heat source for fuel oil (FO) and lubricating oil (LO) tanks?
What is used as a heat source for fuel oil (FO) and lubricating oil (LO) tanks?
Where does the drain from the saturated steam return to?
Where does the drain from the saturated steam return to?
What is used to make up for shortages in the cascade tank drain?
What is used to make up for shortages in the cascade tank drain?
Where are boiler compounds injected for proper boiler water management?
Where are boiler compounds injected for proper boiler water management?
Signup and view all the answers
What is used to convey fresh water to the auxiliary boiler?
What is used to convey fresh water to the auxiliary boiler?
Signup and view all the answers
What is the purpose of the inspection tank in the boiler water management system?
What is the purpose of the inspection tank in the boiler water management system?
Signup and view all the answers
When is it appropriate to dissolve and inject boiler compounds into the cascade tank?
When is it appropriate to dissolve and inject boiler compounds into the cascade tank?
Signup and view all the answers
Where should a boiler water sample be taken from for testing?
Where should a boiler water sample be taken from for testing?
Signup and view all the answers
What action is recommended based on the results of the boiler water test?
What action is recommended based on the results of the boiler water test?
Signup and view all the answers
What is the purpose of the inspection tank in the boiler water management system?
What is the purpose of the inspection tank in the boiler water management system?
Signup and view all the answers
Where does the drain from the saturated steam return to in the boiler water management system?
Where does the drain from the saturated steam return to in the boiler water management system?
Signup and view all the answers
When is it appropriate to dissolve and inject boiler compounds into the cascade tank for proper boiler water management?
When is it appropriate to dissolve and inject boiler compounds into the cascade tank for proper boiler water management?
Signup and view all the answers
What action is recommended based on the results of the boiler water test in terms of managing impurities?
What action is recommended based on the results of the boiler water test in terms of managing impurities?
Signup and view all the answers
What is the recent trend in marine boilers that has emphasized the importance of water quality management?
What is the recent trend in marine boilers that has emphasized the importance of water quality management?
Signup and view all the answers
In which type of ships are main boilers typically used?
In which type of ships are main boilers typically used?
Signup and view all the answers
What is imperative to prevent turbine plant accidents in relation to water quality?
What is imperative to prevent turbine plant accidents in relation to water quality?
Signup and view all the answers
What must be ensured to meet the requisite quality standards for feed water, condensate, and boiler water?
What must be ensured to meet the requisite quality standards for feed water, condensate, and boiler water?
Signup and view all the answers
Where is the main boiler feed water/condensate used in?
Where is the main boiler feed water/condensate used in?
Signup and view all the answers
What is highlighted as important to manage and maintain in terms of water quality?
What is highlighted as important to manage and maintain in terms of water quality?
Signup and view all the answers
Study Notes
Boiler Water Management System
- Electric heaters are used as a heat source for fuel oil (FO) and lubricating oil (LO) tanks.
- The drain from the saturated steam returns to the cascade tank.
- Fresh water from the auxiliary boiler is used to make up for shortages in the cascade tank drain.
- Boiler compounds are injected into the boiler drum for proper boiler water management.
- Fresh water is conveyed to the auxiliary boiler through the feedwater system.
- The inspection tank is used to inspect and maintain the quality of boiler water.
- Boiler compounds should be dissolved and injected into the cascade tank during low-load or standby periods.
- Boiler water samples should be taken from the boiler drum or downcomer for testing.
- Based on the results of the boiler water test, adjustments should be made to the chemical dosage and blowdown rate to manage impurities.
- The inspection tank is used to inspect and maintain the quality of boiler water.
- The drain from the saturated steam returns to the cascade tank.
- Boiler compounds should be dissolved and injected into the cascade tank during low-load or standby periods for proper boiler water management.
- Based on the results of the boiler water test, adjustments should be made to the chemical dosage and blowdown rate to manage impurities and maintain water quality.
- The recent trend in marine boilers emphasizes the importance of water quality management.
- Main boilers are typically used in large container ships, cruise ships, and other vessels that require high power output.
- It is imperative to prevent turbine plant accidents by maintaining good water quality.
- It is essential to ensure that the requisite quality standards for feed water, condensate, and boiler water are met.
- The main boiler feed water/condensate is used in the steam turbine.
- It is important to manage and maintain the quality of feed water, condensate, and boiler water to prevent turbine plant accidents.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge of the steam and feed water flow diagram for a composite boiler. Understand the utilization of saturated steam for various heating and galley purposes, and its drainage process in the system.