What is the purpose of the containment boot on D-401, and where is the collected water routed?

The containment boot on D-401 is designed to remove any water entrained in the C6+ feed. The collected water is then routed to D-353.

Describe the function of E-401, including the heating medium used and a condition under which it's bypassed.

E-401 preheats the C6+ feed using 100 psig steam. It can be bypassed if the feed originates directly from the bottom of T-380.

Explain the separation process that occurs in T-400, listing the two resulting streams and their destinations.

T-400 separates the partially vaporized C6+ feed into an overhead vapor stream (C6-C10) which goes to E-400, and a bottom liquid stream (C12-C30+) which goes to E-405.

Describe the dual function of P-400A/B and the two possible destinations of the liquid they pump from D-400.

<p>P-400A/B pumps liquid from D-400 either back to T-400 as reflux or to T-410 as feed.</p> Signup and view all the answers

Explain the function of E-405 and its role in temperature control of the bottom of T-400.

<p>E-405, a reboiler, heats the bottom liquid stream from T-400 using Dowtherm. The resulting overhead vapor is sent back to the bottom of T-400 to provide temperature control.</p> Signup and view all the answers

Flashcards

D-401 (C6-C10 Tower Feed Coalescer)

Removes entrained water from the C6+ feed using a containment boot.

E-401 (C6-C10 Tower Feed Preheater)

Heats the C6+ feed using 100 psig steam.

E-403 (C6-C10 Tower Feed Vaporizer)

Partially vaporizes the heated C6+ feed using 400 psig steam.

T-400 (C6-C10 Tower)

Separates the partially vaporized C6+ feed into overhead vapor (C6-C10) and bottom liquid (C12-C30+).

Signup and view all the flashcards

E-400 (C6-C10 Tower Condenser)

Cools the overhead vapor stream (C6-C10) using cooling water.

Signup and view all the flashcards

Study Notes

  • C6+ feed goes to the top of D-401 (C6-C10 Tower Feed Coalescer).
  • Entrained water in D-401 drops into a containment boot and goes to D-353.
  • C6+ feed exits D-401 and goes to the tube side of E-401 (C6-C10 Tower Feed Preheater).
  • In E-401, the C6+ feed is heated by 100 psig steam on the shell side.
  • E-401 is not needed if the feed comes directly from T-380 bottom.
  • Heated C6+ feed goes to the tube side of E-403 (C6-C10 Tower Feed Vaporizer).
  • In E-403, the C6+ feed is partially vaporized by 400 psig steam on the shell side.
  • The partially vaporized C6+ feed goes to T-400.
  • In T-400, the feed is separated into an overhead vapor stream (C6-C10) and a bottom liquid stream (C12-C30+).
  • The T-400 overhead vapor stream goes to the shell side of E-400 (C6-C10 Tower Condenser).
  • In E-400, the vapor is cooled by cooling water on the tube side.
  • Condensed vapor from E-400 goes to the bottom of D-400 (C6-C10 Tower Reflux Drum).
  • Any entrained water in D-400 separates and goes to D-433 (Process Water Surge Drum).
  • Non-condensable vapor from D-400 is vented to D-531 (Vent Header K.O. Drum).
  • P-400A/B (C6-C10 Tower Reflux & Product Pumps) route liquid from D-400 back to T-400 as reflux or to T-410 (C6 Tower) as feed.
  • The T-400 bottom liquid stream is routed to the shell side of E-405 (C6-C10 Tower Reboiler).
  • In E-405, the liquid is heated by Dowtherm on the tube side.
  • Vapor from E-405 is routed back to the bottom of T-400 for temperature control.
  • P-405A/B (C6-C10 Tower Bottom Pumps) route the liquid bottom from E-405 to T-430 (C12-C24 Tower) as feed.

Equipment Details

  • D-401 (C6-C10 Tower Feed Coalescer), removes water from the product stream, dimensions are 2’D x 9’L.
  • E-401 (C6-C10 Tower Feed Preheater) heats the C6+ feed to T-400, using 100 psig steam.
  • E-403 (C6-C10 Tower Feed Vaporizer) vaporizes the C6+ feed to T-400, using 400 psig steam.
  • T-400 (C6-C10 Tower) separates C6-C10 from C12-C30+, dimensions are 5’D x 72’3”H.
  • T-400 keeps C12 concentration in the overhead and C10 concentration at the bottoms within specification.
  • C6+ feed enters the side of T-400, C6-C10 exits the top, and C12-C30+ exits the bottom.
  • E-400 (C6-C10 Tower Condenser) cools and condenses overhead vapor from T-400.
  • D-400 (C6-C10 Tower Reflux Drum) separates liquid for reflux to T-400 and feed for T-410 from non-condensable vapor, dimensions are 4’D x 20’L.
  • Water collected in D-400 is sent to D-430.
  • P-400A/B (C6-C10 Tower Reflux & Product Pumps) circulate reflux to T-400 and routes feed to T-410, using single-stage centrifugal pumps driven by 20 HP 3550 RPM motors.
  • E-405 (C6-C10 Tower Reboiler) boils bottoms into a vapor.
  • E-405 is a kettle-type reboiler that heats T-400 bottoms with Dowtherm.
  • Vapor goes out of E-405 top nozzle, and remaining liquid goes out the bottom nozzle.
  • P-405A/B (C6-C10 Tower Bottom Pumps) route liquid bottom to T-430 as feed, using single-stage centrifugal pumps driven by 20 HP 3550 RPM motors.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

More Like This

C6: Radiological Monitoring and Method - Area
15 questions
C6, P2 Chp 31: Reproductive System Flashcards
44 questions
C6-C10 Tower System Overview
20 questions

C6-C10 Tower System Overview

WellEducatedEllipse6137 avatar
WellEducatedEllipse6137
Use Quizgecko on...
Browser
Browser