Building Permit Application Guidelines
37 Questions
3 Views

Building Permit Application Guidelines

Created by
@FruitfulPanPipes

Questions and Answers

What is the main construction material for Type II buildings?

  • Brick only
  • Masonry and concrete
  • Steel and iron
  • Wood with fire-resistant materials (correct)
  • Which type of building construction allows the use of fire-retardant treated wood for non-bearing partitions?

  • Type V
  • Type II (correct)
  • Type I
  • Type IV (correct)
  • What is the required fire-resistive rating for exterior walls in Type III buildings?

  • Two-hour fire-resistive
  • Non-combustible (correct)
  • One-hour fire-resistive
  • Fire-retardant treated
  • Which types of construction are permitted for Type IV buildings' walls and ceilings?

    <p>Steel, iron, concrete, or masonry</p> Signup and view all the answers

    Which type of building is explicitly classified as fire-resistive?

    <p>Type V</p> Signup and view all the answers

    What is required for someone to obtain a building permit?

    <p>An application in writing on a prescribed form</p> Signup and view all the answers

    Which document must be submitted if the applicant is not the registered owner of the lot?

    <p>A copy of the contract of lease</p> Signup and view all the answers

    What information must be included in a building permit application regarding the proposed work?

    <p>A description of the work to be covered by the permit</p> Signup and view all the answers

    Who is authorized to order discontinuance of occupancy for violations of the Code?

    <p>Building Officials</p> Signup and view all the answers

    How many sets of plans must be submitted with a building permit application at a minimum?

    <p>Five sets</p> Signup and view all the answers

    What must be included in the application regarding the estimated costs?

    <p>The estimated cost of the proposed work</p> Signup and view all the answers

    What types of engineers need to sign and seal the submitted plans according to the Code?

    <p>Both mechanical and electrical engineers</p> Signup and view all the answers

    What aspect of the building's intended use is required in the permit application?

    <p>The use or occupancy for which the proposed work is intended</p> Signup and view all the answers

    Which type of occupancy is categorized under Group A?

    <p>Residential dwellings</p> Signup and view all the answers

    What defines a Group B occupancy?

    <p>Multiple dwelling units accommodating more than 10 persons</p> Signup and view all the answers

    Which of the following is NOT classified under Group C?

    <p>Mental hospitals</p> Signup and view all the answers

    What is the primary characteristic of Group D occupancies?

    <p>They include mental hospitals and jails</p> Signup and view all the answers

    Which group includes business and mercantile occupancy?

    <p>Group E</p> Signup and view all the answers

    Which division of Group E includes gasoline filling stations?

    <p>Division 1</p> Signup and view all the answers

    What type of establishments are classified as Group E Division 2?

    <p>Wholesale and retail stores</p> Signup and view all the answers

    What occupancy type is associated with a capacity of less than one hundred persons under Group D?

    <p>Restaurants</p> Signup and view all the answers

    What should be ensured about the supports and braces of a sign?

    <p>They must not obstruct any traffic signs.</p> Signup and view all the answers

    What is prohibited regarding the construction of signs?

    <p>Signs can obstruct natural views of the landscape.</p> Signup and view all the answers

    What design consideration is required for signs in relation to building loads?

    <p>They must transmit loads through the building's structural frame.</p> Signup and view all the answers

    How should the earth be placed over footings of signs?

    <p>It must be placed carefully and compacted thoroughly.</p> Signup and view all the answers

    What is required for signs erected near high voltage power lines?

    <p>They must comply with the Philippine Electrical Code.</p> Signup and view all the answers

    How should signs be positioned in relation to fire escapes, exits, or standpipes?

    <p>They should not obstruct any openings for free usage.</p> Signup and view all the answers

    What maintenance is required for the display of signs?

    <p>They must be kept neatly painted and secured at all times.</p> Signup and view all the answers

    What should be avoided when designing signs?

    <p>Sign designs that might create a traffic hazard.</p> Signup and view all the answers

    Under what condition can existing buildings in fire zones be moved?

    <p>When they are entirely demolished</p> Signup and view all the answers

    What is the maximum value of repairs allowed per year for existing buildings without requiring compliance updates?

    <p>Twenty percent of the existing building's value</p> Signup and view all the answers

    What type of materials can be used for repairs on existing buildings after fire or earthquake damage?

    <p>The same kind of materials as originally constructed</p> Signup and view all the answers

    What does the term 'fire-resistive rating' refer to?

    <p>The degree to which a material can withstand fire</p> Signup and view all the answers

    What is a requirement for changes or alterations to existing buildings in fire zones concerning combustible materials?

    <p>Changes must not add additional combustible materials</p> Signup and view all the answers

    What classification method must be used for buildings proposed for construction?

    <p>According to their use or occupancy character</p> Signup and view all the answers

    Which condition allows for modifications to existing buildings in fire zones?

    <p>If the value of work does not exceed certain limits</p> Signup and view all the answers

    What is a key factor in determining if changes to an existing building increase fire hazard?

    <p>The judgement of the Building Official</p> Signup and view all the answers

    Study Notes

    Building Official Authority

    • Authorized to halt occupancy or use of any structure violating code provisions.

    Application for Building Permits

    • Written application required for obtaining a building permit.
    • Must include:
      • Work description for the project.
      • Certified true copy of the Transfer Certificate of Title (TCT) for the lot.
      • If not the owner, submit TCT and lease contract.
      • Intended use or occupancy of the project.
      • Estimated cost of proposed work.
    • Requires five sets of plans and specifications, prepared and sealed by registered engineers.

    Certificate of Occupancy

    • Must be posted conspicuously on premises.
    • Removal only by order of the Building Official.

    Types of Buildings and Fire-resistive Requirements

    • Type II: Wood with fire-resistant materials; one-hour fire-resistive.
    • Type III: Masonry and wood; one-hour fire-resistive.
    • Type IV: Steel, iron, concrete, or masonry; requires incombustible materials.
    • Type V: Fire-resistive; structural elements must be incombustible.

    Fire Zones Regulation

    • Specific building types allowed based on use and fire resistance.
    • Existing structures in fire zones must comply with new regulations unless:
      • Entirely demolished.
      • Moved to a less restrictive zone.
      • Changes not exceeding 20% of existing building's value, not increasing fire hazard.

    Fire-resistive Rating

    • Indicates a material's capability to withstand fire based on recognized tests.

    Occupancy Classifications

    • Group A: Residential dwellings.
    • Group B: Hotels and apartments accommodating more than 10 persons.
    • Group C: Educational and recreational buildings.
    • Group D: Institutions like mental hospitals and correctional facilities.
    • Group E: Businesses and mercantile spaces with specific divisions for types of establishments.

    Sign Regulations

    • Signs must not obstruct traffic views or aesthetic values.
    • Maintenance of signs is required for safety and preservation.
    • Design must comply with structural and safety codes:
      • Adequate clearance from power lines.
      • Free access to fire escapes and exits.
      • Cannot obstruct light or ventilation openings as per code requirements.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz focuses on the essential guidelines for applying for building permits, including required documentation and occupancy regulations. It also covers the types of buildings and their fire-resistive requirements. Test your knowledge on the procedures and codes governing building permits.

    More Quizzes Like This

    Use Quizgecko on...
    Browser
    Browser