🎧 New: AI-Generated Podcasts Turn your study notes into engaging audio conversations. Learn more

Building Occupancy Change Regulations
12 Questions
1 Views

Building Occupancy Change Regulations

Created by
@FeistyHyperbola

Podcast Beta

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What are the types of Occupancy Separation based on fire-resistive rating?

  • Four types: One-Hour, Two-Hour, Three-Hour, Four-Hour (correct)
  • Two types: One-Hour, Three-Hour, Four-Hour
  • Three types: One-Hour, Two-Hour, Three-Hour
  • Five types: One-Hour, Two-Hour, Three-Hour, Four-Hour, Five-Hour
  • What type of fire-resistive construction is required for a 'Three-Hour Fire-Resistive Occupancy Separation'?

  • Four-hour fire-resistive construction
  • One-hour fire-resistive construction
  • Two-hour fire-resistive construction
  • Three-hour fire-resistive construction (correct)
  • How are openings in a 'One-Hour Fire-Resistive Occupancy Separation' protected?

  • With no protection needed
  • With three-hour fire-resistive rating
  • With a one-hour fire-resistive rating (correct)
  • With two-hour fire-resistive rating
  • What is required for the total width of all openings in a 'Three-Hour Fire-Resistive Occupancy Separation wall'?

    <p>Cannot exceed 25% of the length of the wall in any storey</p> Signup and view all the answers

    What type of fire-resistive construction is required for a 'Two-Hour Fire-Resistive Occupancy Separation'?

    <p>Two-hour fire-resistive construction</p> Signup and view all the answers

    What is the minimum required occupancy separation if any separation is needed?

    <p>'One-Hour Fire-Resistive Occupancy Separation'</p> Signup and view all the answers

    What is the requirement when changing the character of occupancy of a building according to Section 702?

    <p>The building must comply with the requirements for the new occupancy.</p> Signup and view all the answers

    What is required when changing the character of occupancy in terms of life and fire risk?

    <p>The new use must be less hazardous than the existing use.</p> Signup and view all the answers

    In mixed occupancy buildings, which requirement applies to the whole building?

    <p>The most restrictive requirement pertaining to any type of occupancy found in the building.</p> Signup and view all the answers

    If a one-storey building houses multiple occupancies, what requirement applies to each portion of the building?

    <p>Each portion must conform to the requirement of the particular occupancy housed therein.</p> Signup and view all the answers

    What restriction applies to minor accessory uses in mixed occupancy buildings?

    <p>They cannot occupy more than 10% of any floor area.</p> Signup and view all the answers

    How is the occupancy classification determined in mixed occupancy buildings with major and minor uses?

    <p>The major use always determines the occupancy classification.</p> Signup and view all the answers

    More Quizzes Like This

    Use Quizgecko on...
    Browser
    Browser