What is one of the conditions that must be met for a building to be considered as separate and distinct buildings?
What is one of the conditions that must be met for a building to be considered as separate and distinct buildings?
Which type of construction is required for a building below a horizontal assembly in a Group S-2 enclosed parking garage with Group S-2 open parking garage above?
Which type of construction is required for a building below a horizontal assembly in a Group S-2 enclosed parking garage with Group S-2 open parking garage above?
What is the maximum allowable area ratio for buildings with multiple separate occupancies?
What is the maximum allowable area ratio for buildings with multiple separate occupancies?
In the context of the text provided, what determines the maximum building height in feet for separate and distinct buildings?
In the context of the text provided, what determines the maximum building height in feet for separate and distinct buildings?
Signup and view all the answers
For using a Group S-2 enclosed parking garage with no more than one story above grade plane and located below a Group S-2 open parking garage, what occupancy classification is required?
For using a Group S-2 enclosed parking garage with no more than one story above grade plane and located below a Group S-2 open parking garage, what occupancy classification is required?
Signup and view all the answers
Study Notes
Construction Requirements for Occupancies
- Each occupancy must apply the specified type of construction individually, except for structural members and main bracing within open parking structures.
- Means of egress for upper occupancies must conform to Chapter 10 and be separated from parking occupancies by fire barriers with at least a 2-hour fire-resistance rating.
Separation Requirements for Group B or M with Group S-2 Open Parking Garage
- Group B or M occupancies can be considered separate buildings for construction purposes if:
- They are separated by a horizontal assembly with a minimum 2-hour fire-resistance rating.
- Occupancies below the horizontal assembly are limited to Groups B and M.
- The occupancy above the horizontal assembly is limited to a Group S-2 open parking garage.
Special Industrial Occupancies
- Buildings designed for special industrial processes can be exempt from building height and area limitations if they require large areas and unusual building heights to accommodate craneways or special machinery and equipment.
Multiple Buildings on the Same Plot
- Two or more buildings on the same plot can be regulated as separate buildings or as portions of one building if the building height of each building and the aggregate building area of the buildings are within the limitations of Table 503.
Type I Construction
- Buildings of Type I construction can be of unlimited tabular building heights and areas, and are not subject to special requirements that allow unlimited area buildings or increased building heights and areas for other types of construction.