Building Construction and Fire Safety Quiz
5 Questions
4 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is a major problem in fire resistive buildings during a fire?

  • The central air conditioning system (correct)
  • The lack of fire walls
  • The size of the floor areas
  • The heat activated fire damper

Which type of building construction is most susceptible to the spread of flame and smoke through concealed spaces and voids?

  • Noncombustible/limited combustible
  • Heavy timber
  • Ordinary brick and joint
  • Fire resistive (correct)

What measures should be taken to fully protect a fire resistive high-rise building?

  • Limiting the size of floor areas
  • Automatic sprinkler system and fire walls (correct)
  • Interconnected concealed spaces and voids
  • Heat activated fire dampers and fire partitions

What is the primary cause of fire deaths?

<p>Smoke (B)</p> Signup and view all the answers

What is the purpose of a heat activated fire damper in a fire resistive building?

<p>To stop smoke spread in air ducts (C)</p> Signup and view all the answers

Study Notes

Major Problems in Fire Resistive Buildings

  • Fire resistive buildings may still face significant challenges, such as smoke spreading rapidly through compartments and shafts.
  • Ineffective fire barriers or inspections can lead to failures in containing fires and smoke, increasing hazards.

Susceptibility in Building Construction

  • Type I construction, characterized by non-combustible materials, is particularly vulnerable to flame and smoke spread through concealed spaces and voids.
  • Concealed spaces, such as those in ceilings and walls, can act as conduits for smoke movement, complicating fire response efforts.

Protection Measures for High-Rise Buildings

  • Implement regular fire drills and emergency response training for occupants and staff to ensure preparedness.
  • Install comprehensive sprinkler systems to quickly address fires.
  • Ensure proper maintenance and inspection of fire safety equipment, including extinguishers and alarms.
  • Use fire-stopping materials in wall and ceiling penetrations to minimize smoke travel and fire spread between compartments.

Primary Cause of Fire Deaths

  • Smoke inhalation is identified as the leading cause of fire-related fatalities, accounting for a majority of deaths during fires.
  • Compounding factors include rapid smoke accumulation and toxic byproducts of combustion that impair survival chances.

Purpose of Heat Activated Fire Dampers

  • Heat activated fire dampers serve to prevent the spread of smoke and flames through ductwork in fire resistive buildings.
  • They automatically close upon detecting high temperatures, thereby enhancing compartmentalization and protecting escape routes.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Description

Test your knowledge of fire standard types of building construction and basic building construction types when dealing with building collapse. Learn about fire resistive, noncombustible/limited combustible, ordinary brick and joint, heavy timber, and wood frame construction. Understand the major problems associated with fire resistive buildings and the potential dangers of interconnected systems and concealed spaces.

More Like This

Building Construction Chapter 12
31 questions

Building Construction Chapter 12

AgileBlueTourmaline7875 avatar
AgileBlueTourmaline7875
International Building Code: Chapter 7 Quiz
24 questions
Construction Safety and Regulations Quiz
42 questions
Use Quizgecko on...
Browser
Browser