Which law governs the electrical systems and installations as per the Electrical Regulations?
Which law governs the electrical systems and installations as per the Electrical Regulations?
- Philippine Electrical Act No. 184
- Commonwealth Act No. 294
- Republic Act No. 184 (correct)
- Republic Act No. 294
What is the maximum allowable weight of film negatives stored in a single cabinet?
What is the maximum allowable weight of film negatives stored in a single cabinet?
- 110 kilograms (correct)
- 300 kilograms
- 450 kilograms
- 200 kilograms
What type of envelopes should be used for storing film negatives?
What type of envelopes should be used for storing film negatives?
- Paper folders
- Heavy Manila envelopes (correct)
- Plastic bags
- Cardboard boxes
How far from heat sources should films be stored?
How far from heat sources should films be stored?
Which type of light is permitted for use in film storage areas?
Which type of light is permitted for use in film storage areas?
What feature must door openings in storage vaults have?
What feature must door openings in storage vaults have?
In which situation must storage rooms for unexposed photographic and x-ray films have automatic fire extinguishing systems?
In which situation must storage rooms for unexposed photographic and x-ray films have automatic fire extinguishing systems?
What must be posted prominently in storage areas for film?
What must be posted prominently in storage areas for film?
Which type of film is exempted from the provisions of Section 1402?
Which type of film is exempted from the provisions of Section 1402?
What is the required storage practice for discarded films?
What is the required storage practice for discarded films?
What distinguishes safety photographic X-ray film?
What distinguishes safety photographic X-ray film?
What must every device used to connect prefabricated assemblies do?
What must every device used to connect prefabricated assemblies do?
Which is NOT a required characteristic of prefabricated assemblies as per the guidelines?
Which is NOT a required characteristic of prefabricated assemblies as per the guidelines?
What must be inspected when placing prefabricated assemblies?
What must be inspected when placing prefabricated assemblies?
What is the purpose of the fire extinguishing system as detailed in Section 1403?
What is the purpose of the fire extinguishing system as detailed in Section 1403?
What is the definition of prefabricated assembly as per Section 1501?
What is the definition of prefabricated assembly as per Section 1501?
What is the maximum area allowed for a section of plastic veneer above the first storey in less restrictive Fire Zones?
What is the maximum area allowed for a section of plastic veneer above the first storey in less restrictive Fire Zones?
Under what condition can plastic light diffusers be installed in a manner that may become detached at temperatures of 80°C?
Under what condition can plastic light diffusers be installed in a manner that may become detached at temperatures of 80°C?
What is the minimum vertical separation required between sections of plastic veneer?
What is the minimum vertical separation required between sections of plastic veneer?
Which of the following can utilize approved plastics in their construction according to the Flame Spread characteristics?
Which of the following can utilize approved plastics in their construction according to the Flame Spread characteristics?
What is the maximum height for plastic veneer attached to exterior walls?
What is the maximum height for plastic veneer attached to exterior walls?
What type of materials may be used in lieu of plain glass in greenhouses located in less restrictive Fire Zones?
What type of materials may be used in lieu of plain glass in greenhouses located in less restrictive Fire Zones?
Which of the following statements about plastic light diffusers is true?
Which of the following statements about plastic light diffusers is true?
What is the requirement for plastic materials used in partitions?
What is the requirement for plastic materials used in partitions?
What is the primary concern regarding the construction of signs in natural landscapes?
What is the primary concern regarding the construction of signs in natural landscapes?
Which of the following is a requirement for the maintenance of signs?
Which of the following is a requirement for the maintenance of signs?
How should sign structures be designed in relation to the National Structural Code for Buildings?
How should sign structures be designed in relation to the National Structural Code for Buildings?
What materials are allowed for signs in highly restrictive Fire Zones?
What materials are allowed for signs in highly restrictive Fire Zones?
What should be considered when placing supports and anchorages for signs?
What should be considered when placing supports and anchorages for signs?
Which type of materials can be used for non-structural trim and portable display surfaces?
Which type of materials can be used for non-structural trim and portable display surfaces?
What is the requirement for display surfaces in all types of signs?
What is the requirement for display surfaces in all types of signs?
What clearance requirement is highlighted for signs near high voltage power lines?
What clearance requirement is highlighted for signs near high voltage power lines?
What is the maximum allowable area for a paint spray booth in square meters?
What is the maximum allowable area for a paint spray booth in square meters?
Which material is specified for the construction of paint spray booth floors?
Which material is specified for the construction of paint spray booth floors?
What is the minimum depth requirement for a fire curtain or metal deflector at the booth opening?
What is the minimum depth requirement for a fire curtain or metal deflector at the booth opening?
What is the minimum ventilation air movement rate required for paint spray booths?
What is the minimum ventilation air movement rate required for paint spray booths?
Which type of glass panels should be used for lighting in paint spray booths?
Which type of glass panels should be used for lighting in paint spray booths?
What is the minimum distance that exhaust ducts must be located from combustible construction?
What is the minimum distance that exhaust ducts must be located from combustible construction?
What gauge of steel is specified as a minimum thickness for paint spray booth construction?
What gauge of steel is specified as a minimum thickness for paint spray booth construction?
What is the requirement for the design of the interior surfaces of paint spray booths?
What is the requirement for the design of the interior surfaces of paint spray booths?
Study Notes
Plastic Light Diffusers in Ceilings
- Ceiling light diffusers larger than 10% of any 10 square meters of a room should be made from approved plastics that meet building code requirements.
- Installation of plastic light diffusers should be done in a way that prevents them from detaching easily when subjected to a room temperature of 80 degrees Celsius for 15 minutes.
- Exceptions are made for plastic light diffusers on the first floor of Group C Occupancies with direct egress to the exterior and those installed between automatic fire-extinguishing systems and the protected area, excluding public corridors in Group A, B, C, D, E, G, H, and I Occupancies, as long as testing by the Secretary confirms they don't interfere with the fire systems.
Partitions
- Approved plastics meeting building code requirements can be used for partitions that aren't required to be fire-resistive or incombustible.
Exterior Veneer
- Plastic materials can be utilized for exterior veneer, subject to the provisions mentioned.
- Plastic veneer is prohibited on exterior walls above the first storey, with exceptions for buildings outside highly restrictive Fire Zones where the veneer height doesn't exceed 10.00 meters above the adjacent grade of elevation.
- Maximum area of plastic veneer sections is 15.00 square meters, with a 50% increase permissible in less restrictive Fire Zones.
- Plastic veneer sections should be separated by at least 1.20 meters vertically and 600 millimeters horizontally.
Awnings and Canopies
- Plastics meeting Flame Spread requirements can be used in awnings and canopies as long as they adhere to the specific provisions on projections and appendages.
- Approved plastics can be used in awnings where untreated canvass is allowed.
- Approved plastics may replace plain glass in green-houses in less restrictive Fire Zones.
Photographic and X-ray Films
- Unexposed photographic and x-ray films exceeding 14.00 cubic meters in storage require automatic fire extinguishing systems.
- The same applies to shelving with a storage capacity exceeding 1.40 cubic meters.
- Film negatives in storage or handling should be stored in heavy Manila envelopes, not exceeding 12 films per envelope.
- Film negatives should be kept in insulated vented cabinets, vaults, or detached structures, with a maximum of 110 kilograms per cabinet.
- Storage exceeding 450 kilograms requires vented storage vaults or a detached structure with four-hour fire-resistive doors.
- Only incandescent electric lights are permitted, protected by guards/vapor-proof globes. Portable lights and smoking are prohibited.
- No films should be stored within 600 millimeters of heat sources.
- First aid provisions using water or water solutions are necessary.
- Discarded films should be stored and handled as normal films until removed from the premises.
- These provisions do not apply to amateur photographic film in original packages less than 1.40 cubic meters, safety film, dental X-ray film, film manufacturers' storage, and films used in standard motion picture booths.
Prefabricated Construction
- Prefabricated assemblies should be pre-built before incorporation into a building and subject to special tests by the Secretary for structural adequacy, durability, soundness, weather and fire resistance.
- Connection devices should be robust enough to maintain the strength of the members as an integral structure.
- Anchorages and connections should be capable of withstanding external and internal forces and conditions.
- Allowance for material displacement during installation of pipes, conduits, or equipment should be factored into structural design.
- Placement of prefabricated assemblies should be inspected for compliance with building codes.
Plastics
- This section provides general guidelines for the use of plastics but does not contain specific details.
Sheet Metal Paint Spray Booths
- Paint spray booths should be made of steel, minimum No. 18 U.S. gauge, and designed in accordance with building codes.
- Maximum area of a paint spray booth is 150 square meters or 10% of the permitted area based on the building's occupancy group.
- The floor should be incombustible.
- Booths should enable free airflow and have smooth, continuous interior surfaces without protruding edges.
- Booths with open fronts over 1.00 square meter lacking doors require a fire curtain or metal deflector at the upper edge.
- Illumination should be provided through hammered wire or heat-treated glass panels.
- Mechanical ventilation is required to the exterior.
- The exhaust system should maintain an air flow rate of at least 30.00 lineal meters per minute.
- Exhaust fans should be non-ferrous and mounted to prevent contact with the exhaust duct.
- Motors should not be installed inside the spray booth or duct system, and belts should be enclosed where they enter those areas.
- Exhaust ducts should be made of steel with a thickness defined by the Secretary. The discharge point should adhere to specified distances from combustible construction and wall openings, with exceptions for waterwash spray booths.
Signs
- Signs should not obstruct views of the landscape, distract drivers, or be aesthetically offensive.
- Support structures need to be maintained and kept in good repair.
- Signs must be designed to withstand all forces in accordance with the National Structural Code.
- Load transmissions from building signs to the ground must be designed to prevent overstressing of building elements.
- Supports and anchorages should be placed on private property.
- Materials for signs must adhere to building code standards.
- Signs in highly restrictive Fire Zones require incombustible materials with exceptions made for ground signs.
- Non-structural trim and portable display surfaces can be made of wood, metal, approved plastics, or a combination of those.
- Display surfaces can be made of metal, glass, or approved plastics.
- Clearances from high voltage power lines should comply with the Philippine Electrical Code.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz covers the building code requirements for the use of plastic materials in ceiling light diffusers, partitions, and exterior veneers. Understand the specifications that ensure safety and compliance in various occupancy groups. Test your knowledge on the exceptions and standards for installation.