Podcast
Questions and Answers
Which clause of the BCA requires that buildings over 25m in effective height must have at least 2 exits provided to each storey?
Which clause of the BCA requires that buildings over 25m in effective height must have at least 2 exits provided to each storey?
What is the minimum secondary water supply storage capacity required for buildings over 25m in effective height, as per the BCA?
What is the minimum secondary water supply storage capacity required for buildings over 25m in effective height, as per the BCA?
Which table in the BCA specifies the requirement for stair pressurisation in buildings over 25m in effective height?
Which table in the BCA specifies the requirement for stair pressurisation in buildings over 25m in effective height?
Which class of buildings or parts of buildings require the provision of zone smoke control/zone pressurisation systems, as per AS/NZS 1668.1?
Which class of buildings or parts of buildings require the provision of zone smoke control/zone pressurisation systems, as per AS/NZS 1668.1?
Signup and view all the answers
Which clause of the BCA specifies the requirement for Emergency Warning and Intercommunication Systems (EWIS)?
Which clause of the BCA specifies the requirement for Emergency Warning and Intercommunication Systems (EWIS)?
Signup and view all the answers
Study Notes
Building Code of Australia (BCA) Requirements
- Clause that mandates at least two exits per storey for buildings with effective height exceeding 25m is crucial for safety and accessibility.
- Minimum secondary water supply storage capacity required for buildings over 25m in effective height is specified to ensure adequate resources during emergencies.
- Table within the BCA outlines the specific requirements for stair pressurisation necessary for buildings taller than 25m to maintain safe evacuation routes.
Smoke Control Systems
- Class of buildings requiring zone smoke control or zone pressurisation systems according to AS/NZS 1668.1 includes high-rise structures and certain commercial buildings to enhance life safety during fires.
Emergency Systems
- Clause in the BCA detailing the requirements for Emergency Warning and Intercommunication Systems (EWIS) is essential for effective communication during emergencies, aiding in timely evacuations.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge on the Building Code of Australia (BCA) requirements for buildings over 25m in effective height versus buildings under 25m. Learn about the 8 main differences between the two, including the number of exits, re-entry from fire isolated exits, and water supply requirements. Challenge yourself and see how well you understand these BCA regulations!