ASME BPVC Section I Part PG-67 Quiz
10 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What should be done if the installed safety valve capacity is adequate for the boiler?

  • The firing rate of the boiler should be determined and adjusted according to manufacturer specifications (correct)
  • The safety valve should be replaced
  • The boiler should be immediately shut down
  • No action is necessary
  • What can cause a furnace explosion?

  • Excessive internal pressure
  • Ignition and explosion of combustible gases within the furnace (correct)
  • Structural weakening of pressure vessels
  • Improper installation of safety valves
  • What action is required in most jurisdictions following a furnace or pressure vessel explosion?

  • Immediate reporting to the Chief Inspector by telephone or telegraph (correct)
  • Reporting to the manufacturer only
  • No action is required
  • Reporting to local law enforcement only
  • What does the New Brunswick Boiler and Pressure Vessel Act require after an explosion?

    <p>Immediate reporting to the Chief Inspector by telephone or telegraph</p> Signup and view all the answers

    Why did the boiler shown in Figure 3 not pass inspection after experiencing a pressure vessel explosion?

    <p>There was structural weakening of the pressure vessel</p> Signup and view all the answers

    What should be done if an overpressure event occurs in a boiler?

    <p>Shut down the boiler, isolate, cool, and drain it, then inform the boiler inspector</p> Signup and view all the answers

    What does ASME BPVC Section I Part PG-67 state regarding pressure relief valve capacity for each boiler?

    <p>It should discharge all the steam that can be generated by the boiler without allowing the pressure to rise excessively</p> Signup and view all the answers

    What is recommended to determine the integrity of the pressure vessel after an overpressure event?

    <p>Conduct a thorough internal and external inspection of the vessel</p> Signup and view all the answers

    What action should be taken if the pressure relief valve fails to open when boiler pressure reaches the safety valve set point?

    <p>Shut down the boiler and address the issue immediately</p> Signup and view all the answers

    What is the purpose of performing an accumulation test on the safety valve?

    <p>To determine if the safety valve can discharge all the steam that can be generated by the boiler</p> Signup and view all the answers