NBC 2015 - Section 3.7 - 01
20 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

According to the National Building Code of Canada 2015, if a service building is required for mobile homes that do not have individual sanitary facilities, it should contain at least one water closet for each sex if the service building facilities serve not more than how many mobile homes?

  • 15
  • 5
  • 10 (correct)
  • 20
  • According to the National Building Code of Canada 2015, if a service building is required for mobile homes that do not have individual sanitary facilities, it should contain at least one bathtub or shower for each sex.

  • False
  • True (correct)
  • According to the National Building Code of Canada 2015, safety glass should not be used for a shower or bathtub enclosure.

  • True (correct)
  • False
  • According to the National Building Code of Canada 2015, what is the minimum distance that wall and floor surfaces below the uppermost surfaces of a urinal should be protected from deterioration by impervious and durable material?

    <p>900 mm</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, a floor drain should be installed in a washroom containing a urinal equipped with an automatic flushing device.

    <p>True</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, grab bars should be able to resist a load of not less than how much applied vertically or horizontally?

    <p>1.3 kN</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, in a hotel or motel, a bathtub should have a clear floor space at least how wide along its length?

    <p>900 mm</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, in a hotel or motel, grab bars located vertically at the end of the bathtub should be not less than how long?

    <p>1200 mm</p> Signup and view all the answers

    According to Section 3.7.1.1, what is the purpose of having a sufficient height in every room and space?

    <p>To provide a comfortable living environment</p> Signup and view all the answers

    According to Section 3.7.2.1, what are the acceptable means for the disposal of human waste if the installation of a sanitary drainage system is not possible due to the absence of a water supply?

    <p>All of the above</p> Signup and view all the answers

    According to Section 3.7.2.2, when are water closets required for each sex assuming that the occupant load is equally divided between males and females?

    <p>When the proportion of each sex expected in the building can be determined with reasonable accuracy</p> Signup and view all the answers

    According to Section 3.7.2.2, when can the total number of persons in the building be reduced by 10 when determining the number of water closets required?

    <p>When a single universal washroom is provided</p> Signup and view all the answers

    According to Section 3.7.2.2, when is the water closet in a single universal washroom not taken into consideration when determining the number of water closets required?

    <p>When a single universal washroom is provided</p> Signup and view all the answers

    According to Section 3.7.2.1, when are waterless urinals permitted to be used in buildings?

    <p>When a water supply is available</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following statements is true about the number of water closets required for assembly occupancies?

    <p>The number of water closets required for assembly occupancies is determined by Table 3.7.2.2.-A.</p> Signup and view all the answers

    In a primary school or daycare centre, how many water closets are required for each sex?

    <p>One for each 30 males and one for each 25 females.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, how many water closets are required for a care or residential occupancy?

    <p>At least one for each 10 persons of each sex.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, how many water closets are required for a mercantile occupancy?

    <p>At least one for each 300 males and one for each 150 females.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, how many water closets are required for an industrial occupancy?

    <p>The number of water closets required for an industrial occupancy is determined by Table 3.7.2.2.-C.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, how many lavatories are required for a room containing 4 water closets?

    <p>At least 2 lavatories.</p> Signup and view all the answers

    More Like This

    NBC 2015 Section 3.1 - 01
    70 questions
    NBC 2015 Section 3.1 - 02
    40 questions
    NBC 2015 Section 3.1 - 04
    35 questions
    NBC 2015 - Section 3.2 - 01
    50 questions
    Use Quizgecko on...
    Browser
    Browser