Apparatus Operations during Freezing Weather
14 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which of the following is not a step required to drain a Tower 22 aerial waterway after use?

  • Place the ladder at a 60° to 70° elevation.
  • Open the aerial straight tip valve and leave it open. (correct)
  • Open the aerial drain located next to the LDH supply connection on the right side of the apparatus.
  • Open the aerial valve located next to the master stream device in the basket.
  • After draining the Reserve Tower 22 aerial waterway, which valves should be left open?

  • Aerial valve only.
  • Aerial drain valve only. (correct)
  • Both aerial drain valve and aerial straight tip valve.
  • Aerial straight tip valve only.
  • Which type of apparatus requires the removal of the appliance from the apparatus piping and draining of all water?

  • Apparatus with prepiped deluge guns. (correct)
  • All apparatus.
  • Apparatus with prepiped aerial waterways.
  • Apparatus with a pump.
  • What is the primary responsibility of the apparatus operator in regards to the pump?

    <p>Monitor the pump to prevent overheating.</p> Signup and view all the answers

    Which of the following is not mentioned in the document as a step for draining an aerial waterway?

    <p>Checking for leaks after draining.</p> Signup and view all the answers

    Based on the document, which apparatus should have its pump drained and left dry after each use?

    <p>Both Tower 22 and Reserve Tower 22.</p> Signup and view all the answers

    What is the primary purpose of the guidelines established for apparatus operations during freezing weather?

    <p>To prevent or minimize frozen components on the apparatus</p> Signup and view all the answers

    By what date must the under pump heat panels be installed on the apparatus each year?

    <p>November 15th</p> Signup and view all the answers

    Which action should be taken after conducting a daily pump test on the apparatus?

    <p>Drain all discharge lines equipped with drains</p> Signup and view all the answers

    What is the specified operation for apparatus pumps when sitting idle at an emergency scene?

    <p>Put the pump in gear to circulate water</p> Signup and view all the answers

    What should an operator do if the under pump heat panels are damaged and cannot be installed by the deadline?

    <p>Complete a work order in time for repairs</p> Signup and view all the answers

    Which apparatus is exempt from running with wet pumps during freezing conditions?

    <p>Reserve Tower 22</p> Signup and view all the answers

    When do these freezing weather guidelines take effect each year?

    <p>November 15th</p> Signup and view all the answers

    What is NOT one of the components that needs to be drained after pump use?

    <p>Water tank overflow</p> Signup and view all the answers

    Study Notes

    Apparatus Operations during Freezing Weather

    • Special precautions must be taken during cold weather operations to prevent or minimize frozen components on the apparatus.
    • Apparatus operators are responsible for following these guidelines from November 15 to April 1.

    Heat Panels

    • Apparatus equipped with under pump heat panels must have them installed by November 15 of each year.
    • If heat panels are damaged, the operator must complete a work order to have them replaced by November 15.

    Draining Procedures

    • After daily apparatus pump tests or any time the pump is used, the following must be drained:
      • All discharge lines equipped with drains
      • All suction lines equipped with drains
      • All relief valve drain cocks for relief and pilot valves
    • All apparatus (except Reserve Tower 22) will run with wet pumps.
    • When an apparatus with a pump is sitting idle at an emergency scene for more than a couple of minutes, the pump must be put in gear to circulate water and prevent freezing.

    Tower 22 and Prepiped Deluge Guns

    • The pump on Tower 22 must be drained of all water and left dry after each use.
    • Prepiped deluge guns must be removed from the apparatus piping and drained of all water after each use.

    Draining Aerial Waterways

    • Apparatus equipped with prepiped aerial waterways must be drained as follows after each use:
      • For Tower 22:
        • Place ladder at 60° to 70° elevation
        • Open aerial drain
        • Open aerial valve
        • Allow water to drain out, then bed the ladder slowly
        • Leave aerial straight tip valve and aerial drain valve open
      • For Reserve Tower 22:
        • Place ladder at 60° to 70° elevation
        • Open aerial drain
        • Open aerial valve
        • Allow water to drain out, then bed the ladder and close all valves
        • Leave aerial valve closed and serial valve open

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Standard Operating Guidelines for the Hoffman Estates Fire Department on equipment operations during freezing weather (Nov 15 - Apr 1).