2x25 kV Auto-Transformer Feed System
80 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is a significant advantage of composite insulators compared to conventional porcelain insulators?

  • Enhanced impact withstand capability (correct)
  • Lower cost of materials
  • Higher weight for easier handling
  • Better hydrophobic properties
  • Which materials are commonly used to make the core of composite insulators?

  • Wood and glass
  • Alumino or resin bonded glass fibre (correct)
  • Copper and ceramic
  • Steel and rubber
  • What characteristic of conventional porcelain insulators makes them susceptible to damage?

  • Lightweight construction
  • High thermal resistance
  • Poor impact withstand capability (correct)
  • Flexible structure
  • How is moisture prevented from entering the composite insulator?

    <p>Through a sealed interface with a special compound</p> Signup and view all the answers

    Which elastomer is mentioned as a material used in the sheds of composite insulators?

    <p>Silicone elastomer</p> Signup and view all the answers

    What problem associated with conventional porcelain insulators does not occur with composite insulators?

    <p>Moisture ingress</p> Signup and view all the answers

    Why are the end fittings of composite insulators usually crimped to the core?

    <p>To ensure mechanical stability</p> Signup and view all the answers

    What type of tests have composite insulators exhibited excellent performance in?

    <p>Simulated pollution tests</p> Signup and view all the answers

    What is a disadvantage of the glazed surface of conventional porcelain insulators?

    <p>It does not have good hydrophobic properties</p> Signup and view all the answers

    Which organization is working towards the introduction of composite insulators?

    <p>RDSO</p> Signup and view all the answers

    What is a main advantage of using dry cast resin transformers?

    <p>Elimination of theft risk</p> Signup and view all the answers

    Which type of relay is currently used for distance protection of the overhead equipment?

    <p>Electromechanical relay</p> Signup and view all the answers

    What is a characteristic of the new static type distance protection relay developed by RDSO?

    <p>Three zone operation</p> Signup and view all the answers

    How long can the time settings be adjusted in the second and third zones of the new relay?

    <p>Zero to 0.5 seconds</p> Signup and view all the answers

    What is the main disadvantage of the electromechanical relay mentioned in the content?

    <p>Prone to trip on normal overloads</p> Signup and view all the answers

    What does the first zone of the new relay typically cover?

    <p>About 80% of the OHE</p> Signup and view all the answers

    What is the purpose of the under voltage relay at the SP?

    <p>To act as primary protection</p> Signup and view all the answers

    What characteristic do the first two zones of the static distance protection relay have?

    <p>A Mho characteristic</p> Signup and view all the answers

    What is a feature of the third zone of the new static relay?

    <p>Lenticular characteristic</p> Signup and view all the answers

    What is a current limitation regarding the static relays with parallelogram characteristics?

    <p>Must be imported</p> Signup and view all the answers

    What is the typical spacing of auto-transformers in the system design?

    <p>15 km</p> Signup and view all the answers

    What is the standard capacity of the auto-transformers mentioned in the content?

    <p>2 MVA</p> Signup and view all the answers

    Which of the following is NOT a parameter proposed to be monitored on the pantograph?

    <p>Height of contact wire</p> Signup and view all the answers

    What is one of the proposed features of the on-board computer in the trailer type car?

    <p>Video recording of arcs</p> Signup and view all the answers

    What type of vehicle is suitable for propulsion both on road and track?

    <p>Rail-cum-Road Vehicle</p> Signup and view all the answers

    Which advantage is associated with dry type cast resin transformers compared to oil filled ones?

    <p>Maintenance free</p> Signup and view all the answers

    Which measurement is taken on the OHE?

    <p>Body lateral acceleration</p> Signup and view all the answers

    What is an essential feature of the transportable self-propelled trolley?

    <p>Extendable swivelling platform</p> Signup and view all the answers

    What is a key measurement related to the quality of current collection on the pantograph?

    <p>Loss of contact</p> Signup and view all the answers

    Which of the following parameters is related to assessing the state of the contact wire?

    <p>Detection of hard spots</p> Signup and view all the answers

    What is the main purpose of using Wood-bridge/V-connected transformers in the traction substations?

    <p>To manage load unbalances within acceptable limits</p> Signup and view all the answers

    What voltage does the incoming extra high voltage power get stepped down to in the traction substation?

    <p>2x25 kV</p> Signup and view all the answers

    How is the 25 kV supply reference established in the traction power supply system?

    <p>Connected to the rail potential</p> Signup and view all the answers

    What is the function of a short neutral section in the overhead equipment (OHE)?

    <p>To facilitate sectioning and paralleling of tracks</p> Signup and view all the answers

    What determines the capacity and spacing of auto-transformers in the system?

    <p>The traffic pattern in the section</p> Signup and view all the answers

    Which component is connected to the overhead catenary wires in the auto-transformer arrangement?

    <p>Mid terminal of the auto-transformer</p> Signup and view all the answers

    Where is a sectioning and paralleling post typically located in relation to traction substations?

    <p>Midway between two adjacent traction substations</p> Signup and view all the answers

    What is the arrangement at the Feeding Post generally similar to?

    <p>25 kV conventional system feeding post</p> Signup and view all the answers

    How many phases do the duplicate feeders from the grid sub-station to the traction substation typically consist of?

    <p>Two phases</p> Signup and view all the answers

    What is an essential feature of the auto-transformer feeding system regarding transformer placement?

    <p>Transformers are placed adjacent to tracks throughout the section</p> Signup and view all the answers

    What is a primary characteristic of composite insulators that distinguishes them from conventional porcelain insulators?

    <p>They can withstand greater impact forces.</p> Signup and view all the answers

    Which of the following materials is specifically mentioned as being used for the sheds of composite insulators?

    <p>Silicone elastomer</p> Signup and view all the answers

    How do composite insulators prevent moisture ingress?

    <p>Through sealed interfaces between materials</p> Signup and view all the answers

    Which disadvantage of traditional porcelain insulators is effectively mitigated by composite insulators?

    <p>Susceptibility to vandalism during handling</p> Signup and view all the answers

    What specialized feature allows composite insulators to perform well in pollution tests?

    <p>Design of the molded sheds</p> Signup and view all the answers

    What aspect of the interface between the core and the sheds in composite insulators is crucial for their performance?

    <p>It is sealed with a special compound.</p> Signup and view all the answers

    Which of the following statements regarding the settings of the discussed relay is accurate?

    <p>Settings must follow specific guidelines.</p> Signup and view all the answers

    Why is the interface between the core and sheds of composite insulators sealed?

    <p>To prevent moisture and tracking</p> Signup and view all the answers

    Which scenario best highlights the significance of composite insulators in modern applications?

    <p>Growing need for enhanced vandal resistance</p> Signup and view all the answers

    What is the primary composite material for the core of composite insulators mentioned in the context?

    <p>Alumino porcelain</p> Signup and view all the answers

    What specific upward force is measurable on the pantograph?

    <p>Acrodynamic upward force</p> Signup and view all the answers

    Which of the following describes a benefit of dry type cast resin transformers?

    <p>Practically maintenance-free</p> Signup and view all the answers

    What is one of the functions of the on-board computer in the proposed trailer type car?

    <p>Data acquisition and processing</p> Signup and view all the answers

    Which parameter is NOT monitored on the overhead equipment (OHE)?

    <p>Pantograph arm length</p> Signup and view all the answers

    What specific aspect of the transportable self-propelled trolley is highlighted?

    <p>It is designed to be transported by truck</p> Signup and view all the answers

    What type of vehicle is suitable for dual propulsion on road and track?

    <p>Rail-cum-road vehicle</p> Signup and view all the answers

    Which parameter is monitored for the quality of current collection on the OHE?

    <p>Loss of contact</p> Signup and view all the answers

    What provides an essential advantage of dry type transformers over oil-filled transformers?

    <p>Reduced maintenance needs</p> Signup and view all the answers

    Which movement is measured regarding the pantograph?

    <p>Horizontal movement</p> Signup and view all the answers

    What is the typical spacing of auto-transformers in the system design mentioned?

    <p>15 km</p> Signup and view all the answers

    What is the primary risk eliminated by using dry cast resin transformers in the context of theft?

    <p>The theft of transformer components</p> Signup and view all the answers

    What characteristic of the electromechanical relay presents a potential problem in distance protection?

    <p>It lacks adequate discrimination between different types of currents</p> Signup and view all the answers

    The static type distance protection relay developed by RDSO uses which type of characteristic for its first two zones?

    <p>Mho characteristic</p> Signup and view all the answers

    What is the purpose of introducing a time delay in the second and third zones of the static distance relay?

    <p>To achieve adequate discrimination between faults</p> Signup and view all the answers

    Which statement describes the third zone of the static distance protection relay?

    <p>It employs an adjustable aspect ratio</p> Signup and view all the answers

    Why are static relays with parallelogram characteristics currently imported?

    <p>Indigenous development efforts are still ongoing</p> Signup and view all the answers

    What is the maximum distance the first zone of the static relay is designed to cover?

    <p>About 80% of the OHE</p> Signup and view all the answers

    What issue is anticipated with the increase in traffic and traction power transformer capacity?

    <p>Greater likelihood of false tripping of the circuit breaker</p> Signup and view all the answers

    What key design aspect distinguishes the static relay from its electromechanical counterpart?

    <p>Multi-zone capability with specific characteristics</p> Signup and view all the answers

    What function does the under voltage relay at the SP serve in the protection scheme?

    <p>It acts as a primary protection mechanism</p> Signup and view all the answers

    What is the purpose of using Wood-bridge/V-connected transformers in the traction substations?

    <p>To reduce unbalance in power supply within acceptable limits</p> Signup and view all the answers

    What is the incoming extra high voltage power stepped down to in the traction substation?

    <p>2x25 kV</p> Signup and view all the answers

    How is the 25 kV supply related to the rail potential in the traction power supply system?

    <p>It is established with respect to the rail through the auto-transformer's midpoint</p> Signup and view all the answers

    What arrangement is typical at the Sectioning and Paralleling Post (SP)?

    <p>It features a short neutral section in the overhead equipment</p> Signup and view all the answers

    What determines the spacing and capacity of the auto-transformers in the system?

    <p>The traffic pattern in the section served</p> Signup and view all the answers

    What is a notable feature of the auto-transformer post in the 2x25 kV system?

    <p>It is situated adjacent to the track throughout the section</p> Signup and view all the answers

    What is the significance of having duplicate feeders from the grid sub-station to the traction substation?

    <p>To provide redundancy and enhance reliability in supply</p> Signup and view all the answers

    Where is the feeder wire supported in relation to the overhead contact/catenary wire?

    <p>It runs parallel and is supported from super masts</p> Signup and view all the answers

    In conditions where the grid system capacity is insufficient, what might happen in the traction substations?

    <p>Failure to manage unbalance within permissible limits</p> Signup and view all the answers

    What is the function of cut-in insulators at the feeder wire?

    <p>To isolate sections during maintenance</p> Signup and view all the answers

    Study Notes

    2x25 kV Auto-Transformer Feed System

    • Incoming power supply scheme mirrors a 25 kV feed system, drawing from the nearest grid substation (132 kV or 220 kV, two-phase).
    • Loads are higher (2-3 times) than 25 kV systems, requiring Wood-bridge/V-connected transformers at traction substations to manage imbalances within acceptable limits. Grid system capacity needs to be sufficient.
    • Power is received at the traction substation by stepping down the extra-high voltage to 2x25 kV via a traction power transformer.
    • 2x25 kV supply is fed to an auto-transformer. One terminal connects to overhead catenary wires, the other to a feeder wire running parallel to the overhead wires (supported from super masts).
    • The auto-transformer's midpoint is connected to the rail, creating a 25 kV supply relative to the rail potential for traction.
    • Auto-transformer capacity and spacing are dictated by section traffic patterns.
    • Distribution is similar to 25 kV conventional systems for the feeding post (FP) and sectioning/paralleling post (SP).
    • Auto-transformer posts are spaced every 15 km, with a 2 MVA capacity. Current distribution is detailed in Figure 11.02.

    Distribution of Traction Power Supply

    • Feeding Post (FP) arrangements mirror 25 kV conventional systems.
    • Sectioning and Paralleling Post (SP) designs are similar to 25 kV conventional SSP systems. Neutral sections are part of the overhead equipment (OHE).
    • Short neutral sections are provided in the OHE opposite feeding posts, and mid-way between adjacent substations to provide grounding.
    • Feeder wire neutral sections are also included, using cut-in insulators.

    Overhead Equipment

    • OHE is similar to 25 kV systems, except for an additional feeder wire running parallel to the overhead contact wire.
    • This feeder wire is insulated at 25 kV from the steel structure and at 2x25 kV from the traction OHE.

    Protective Systems

    • Include relays and protection devices for transformer protection; specific relays are designed for 2x25 kV AT feed systems; these include distance relays, AC failure detection devices, and over-current relays.

    OHE Recording-cum-Test Car

    • Crucial to maintain precise overhead equipment geometry for reliable current collection (height, stagger, contact wire conditions).
    • Manual monitoring is prone to inaccuracies; a mechanized monitoring system is needed.
    • Increased freight/passenger traffic and higher train speeds necessitate evaluating existing OHE and pantograph systems for improvements.
    • A dedicated Overhead Equipment Recording cum Test Car is in development to measure and record OHE and pantograph parameters under both static and dynamic conditions (speeds up to 200 km/h).

    Transformer and Auxiliary Transformer

    • Conventional oil-filled transformers require maintenance; dry-type cast resin transformers are more reliable and maintenance-free.
    • Dry-type transformers eliminate fire and explosion risks.

    Static Distance Protection Relay

    • Electromechanical relays, prone to tripping on normal overloads, are less effective in current schemes.
    • Static distance protection relay (3-zone) with adjustable time-settings are more advanced.
    • This relay uses a lenticular characteristic.
    • This relay can be used as a method for backup protection in case of feed extension.
    • An alternative is a static relay with a parallelogram characteristic; this is being developed indigenously.

    Composite Insulators

    • Conventional porcelain insulators have limited impact resistance, break easily, and are not hydrophobic.
    • Composite insulators (porcelain or resin bonded glass fiber with elastomeric/plastic sheds) offer improved impact resistance and eliminate moisture ingress, making them more reliable.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    This quiz explores the 2x25 kV auto-transformer feed system used for traction supply. It covers the incoming power supply scheme, transformer management, and distribution patterns necessary to maintain efficient rail operations. Test your understanding of these critical concepts!

    More Like This

    EL25 Auto-transformers and Instrument Transformers
    37 questions
    EL25 Topic Assessment 2: Auto-transformers
    12 questions
    Auto-transformers and Instrument Transformers
    12 questions
    Use Quizgecko on...
    Browser
    Browser