Tabelas Curso Pedro (1) PDF
Document Details
Uploaded by SupremeGuitar
Tags
Summary
This document provides examples of calculating electrical energy consumption for various appliances, following the ABNT NBR-5410 2004 standards and is relevant for electric calculation.
Full Transcript
VOTAGEM (TENSÃO) AMPERAGEM (CORRENTE) POTENCIA (W) ENERGIA (KWH) (NESSE CASO SERIA A POTENCIA X TEMPO) CALCULAR O CONSUMO DE ENERGIA) EXEMPLO DE TARIFA ENEL DE R$ 1,10 PARA CADA KWH DE CONSUMO EX1 : COMPUTADOR 500W DE POTÊNCIA OU 0.5KW LIGADO 1 HORA AO DIA TERÁ UM CONSUMO DE 0.5KWH/DIA. SE FICAR L...
VOTAGEM (TENSÃO) AMPERAGEM (CORRENTE) POTENCIA (W) ENERGIA (KWH) (NESSE CASO SERIA A POTENCIA X TEMPO) CALCULAR O CONSUMO DE ENERGIA) EXEMPLO DE TARIFA ENEL DE R$ 1,10 PARA CADA KWH DE CONSUMO EX1 : COMPUTADOR 500W DE POTÊNCIA OU 0.5KW LIGADO 1 HORA AO DIA TERÁ UM CONSUMO DE 0.5KWH/DIA. SE FICAR LIGADO OS 30 DIAS POR 1 HORA AO DIA TEREMOS UM CONSUMO DE: 0.5 (KW/DIA) X 30 (DIAS) = 15KWH/MES LOGO COM A TARIFA DE R$ 1,10 X 15KWH/MÊS DE CONSUMO, A CONTA DE ENERGIA VIRÁ: R$ 1,10 (TARIFA) x 15KWH (CONSUMO DE ENERGIA) = R$ 16,50 NA CONTA DE LUZ LIGADO 10 HORA AO DIA TERÁ UM CONSUMO DE 5KWH/DIA. SE FICAR LIGADO OS 30 DIAS POR 10 HORA AO DIA TEREMOS UM CONSUMO DE: 5 (KW/DIA) X 30 (DIAS) = 150KWH/MES LOGO COM A TARIFA DE R$ 1,10 X 150KWH/MÊS DE CONSUMO, A CONTA DE ENERGIA VIRÁ: R$ 1,10 (TARIFA) x 150KWH (CONSUMO DE ENERGIA) = R$ 165,00 NA CONTA DE LUZ EX1 : CHUVEIRO ELÉTRICO 5500W DE POTÊNCIA OU 5.5KW QUANDO SE FALA NA POTENCIA EM CONSUMO (5.5KW) SEMPRE SE REFERE EM 1 HORA DE USO. LOGO UMA HORA DE USO TEMOS 60 MINUTOS. NESSE CASO O CONSUMO POR MINUTO SERIA: 5.000W / 60 MINUTOS. LOGO CADA MINUTO CONSOME 91,66W (VALOR ARREDONDADO) DE ENERGIA DA CONCESSIONÁRIA UM BANHO DE 10 MINUTOS AO DIA TERÁ UM CONSUMO DE (5.500W/60 MINUTOS) X 10 MINUTOS = 916,6WH/DIA OU 0,916KWH/DIA TOMANDO BANHO TODOS OS 30 DIAS POR 1O MINUTOS AO DIA TEREMOS UM CONSUMO DE: 0.916 (KW/DIA) X 30 (DIAS) = 27,48KWH/MES LOGO COM A TARIFA DE R$ 1,10 X 27,48KWH/MÊS DE CONSUMO, A CONTA DE ENERGIA VIRÁ: R$ 1,10 (TARIFA) x 27,48KWH (CONSUMO DE ENERGIA) = R$ 30,22 NA CONTA DE LUZ EXEMPLO DE REFERÊNCIA DEPOTÊNCIA DE EQUIPAMENTOS ELÉTRICOS: LEMBRANDO QUE CADA EQUIPAMENTO VARIA CONFORME O FABRICANTE. CALCULANDO A FIAÇÃO PARA EQUIPAMENTOS ELÉTRICO TODAS AS INFORMAÇÕES A SEGUIR SÃO RETIRADAS DA ABNT NBR-5410 DE 2004 (INSTALAÇÃO ELÉTRICA DE BAIXA TENSÃO). SOMOS OBRIGADOS A SEGUIR AS REFENCIAS DESSA NORMA (ELETRICISTA, ELETROTÉCNICO, ENGENHEIRO, FABRICANTES ETC.) TABELA DE CONDUÇÃO DE CORRENTE SEM LEVAR EM CONSIDERAÇÃO AS PERDAS QUE VEREMOS A SEGUIR. TABELAS PARA CONSULTA RETIRADOS DA NBR- 5410 UTILIZAR MÉTODO B1 COM 2 CONDUTORES CARREGADOS (MAIS UTILIZADO EM RESIDÊNCIA) 2 CONDUTORES CARREGADOS: TV, CHUVEIRO, LÂMPADAS ETC. OU SEJA INSTALAÇÃO FESE-NEUTRO 127V OU FASE-FASE 220V 3 CONDUTORES CARREGADOS (EQUIPAMENTOS TRIFÁSICOS) EX: MOTORES DE ALTA PERFORMACE MÉTDO DE INSTALAÇÃO/APLICAÇÃO: LOCAL ONDE OS CABOS ELÉTRICOS SERÃO INSTALADOS. NESSE CASO USAMOS O MÉTODO B1 POIS É O MAIS UTILIZADO EM RESIDÊNCIAS) CURIOSIDADE: OS CABOS ELÉTRICOS PERDEM A CONDUTIVIDADE DE ACORDO QUE SOFREM AQUECIMENTO. SEJA POR EFEITO JOULE OU POR TEMPERATURA AMBIENTE POR EXEMPLO. LOGO QUANTO MAIS VENTILADO E REFRIGERADO ESTÃO OS CABOS ELÉTRICOS MAIOR SERÁ A CONDUTIVIDADE DO CABO. POR ESSE MOTIVO EXISTE O MÉTODO DE APLICAÇÃO. OS CABOS SEM ISOLAÇÃO NAS RUAS SÃO OS QUE MAIS CONDUZEM ELÉTRICIDADE, PORÉM EXISTE TODO O RISCO DE CHOQUE E CURTO CIRCUITO. É TOTALMENTE PROIBIDO DEIXAR UM CONDUTOR ELÉTRICO SEM ISOLAÇÃO OU PROTEÇÃO MECÂNICA AO CONTATO HUMANO SOB RISCO DE RESPONDER CRIMINALMENTE PELO ERRO DE EXECUÇÃO. FATORES DE AGRUPAMENTO: QUANTO MAIS CIRCUITOS ELÉTRICOS PASSAREM NO MESMO CONDUTOR, MENOR SERÁ A CAPACIDADE DE CONDUÇÃO DE ELETRICA. POR ISSO TEMOS A TABELA DE AGRUPAMENTO ONDE VEMOS O PERCENTUAL DE PERDAS. EX: SE EM UMA TUBULAÇÃO PASSAR 3 CIRCUITOS ELÉTRICOS COMO ILUMINAÇÃO, TOMADA E CHUVEIRO ELÉTRICO. TOTAL DE 3 CIRCUITOS TEMOS UM PERCENTUAL DE CONDUÇÃO DE 70% EM TODOS OS CIRCUITOS ELÉTRICOS. CALCULANDO A FIAÇÃO DE UM EQUIPAMENTO CONFORME NBR 5410 (MÉTODO SIMPLIFICADO) LEVANDO EM CONSIDERAÇÃO AS TABELAS ACIMA. PORÉM EXISTE OUTROS FATORES QUE GERAM MAIS PERDAS MAS NÃO ESTAMOS LEVANDO EM CONSIDERAÇÃO NESSE MOMENTO COMO (DISTÂNCIA, TEMPERATURA AMBIENTE ETC.) EXEMPLO 1: 1 CUVEIRO ELÉTRICO COM POTÊNCIA DE 5500W INSTALADO EM REDE 127V. 5.500W/127V= 43,3A SE ESTIVER PASSANDO EM UMA TUBULAÇÃO COM 3 CIRCUITOS ELETRICOS PASSANDO JUNTOS COMO ILUMINAÇÃO, TOMADAS COZINHA E O PRÓPRIO CIRCUITO DO CHUVEIRO, TEMOS UM FATOR DE AGRUPAMENTO DE 3 CIRCUITOS. LOGO TEMOS UMA PERDA DE 70% ONDE DEVEMOS CONSIDERAR NO CÁLCULO. LOGO 43,3A/0.7 (FATOR AGRUPAMENTO) = CORRENTE CORRIGIDA DE 61,85A CONFORME A TABELA DE CAPACIDADE DE CONDUÇÃO, O CABO A SER UTILIZADO DEVERÁ SER DE 16MM QUE TEMOS UMA CAPACIDADE MÁXIMA DE 76ª DE CONDUÇÃO CURIOSIDADE: A CORRENTE REAL DO CHUVEIRO MEDIDA EM APARELHOS SEMPRE SERÁ 43,3A. POREM TEMOS QUE USAR ESSAS CORREÇÕES, SENÃO NÃO TEREMOS A ENERGIA CHEGANDO DA MANEIRA CORRETA NOS EQUIPAMENTOS E A CONSEQUENCIA SERÁ DO CHUVEIRO NÃO AQUECENDO DA MANEIRA CORRETA. EXEMPLO 2: 1 CUVEIRO ELÉTRICO COM POTÊNCIA DE 5500W INSTALADO EM REDE 220V. 5.500W/220V= 25A SE ESTIVER PASSANDO EM UMA TUBULAÇÃO COM 3 CIRCUITOS ELETRICOS PASSANDO JUNTOS COMO ILUMINAÇÃO, TOMADAS COZINHA E O PRÓPRIO CIRCUITO DO CHUVEIRO, TEMOS UM FATOR DE AGRUPAMENTO DE 3 CIRCUITOS. LOGO TEMOS UMA PERDA DE 70% ONDE DEVEMOS CONSIDERAR NO CÁLCULO. LOGO 25A/0.7 (FATOR AGRUPAMENTO) = CORRENTE CORRIGIDA DE 35.71A CONFORME A TABELA DE CAPACIDADE DE CONDUÇÃO, O CABO A SER UTILIZADO DEVERÁ SER DE 6MM QUE TEMOS UMA CAPACIDADE MÁXIMA DE 41A DE CONDUÇÃO OBS: A CORRENTE REAL DO CHUVEIRO MEDIDA EM APARELHOS SEMPRE SERÁ 25A. POREM TEMOS QUE USAR ESSAS CORREÇÕES, SENÃO NÃO TEREMOS A ENERGIA CHEGANDO DA MANEIRA CORRETA NOS EQUIPAMENTOS E A CONSEQUENCIA SERÁ DO CHUVEIRO NÃO AQUECENDO DA MANEIRA CORRETA. CURIOSIDADE: SEMPRE QUE UTILIZAR UM EQUIPAMENTO EM VOLTAGEM (TENSÃO) MAIOR, TEREMOS UMA MENOR CORRENTE NOS CABOS ECONOMIZANDO EM R$ NA FIAÇÃO. PORÉM QUANTO MAIOR A VOLTAGEM, MAIOR MAIOR É O RISCO DE CHOQUE ELÉTRICO E DANO A VIDA HUMANA. ENTÃO DEVEMOS SER CRITERIOSOS NA HORA DE ESCOLHER A VOLTAGEM CORRETA NOS EQUIPAMENTOS. EXEMPLO 3: 1 CUVEIRO ELÉTRICO COM POTÊNCIA DE 5500W INSTALADO EM REDE 127V. 5.500W/127V= 43,3A SE ESTIVER PASSANDO EM APENAS UMA TUBULAÇÃO TEMOS UM FATOR DE AGRUPAMENTO DE 1 CIRCUITO. LOGO NÃO TEMOS PERDA POR AGRUPAMENTO. LOGO 43,3A/1 (FATOR AGRUPAMENTO) = CORRENTE CORRIGIDA DE 43,3A CONFORME A TABELA DE CAPACIDADE DE CONDUÇÃO, O CABO A SER UTILIZADO DEVERÁ SER DE 10MM QUE TEMOS UMA CAPACIDADE MÁXIMA DE 57A DE CONDUÇÃO. CURIOSIDADE: SEMPRE QUE POSSÍVEL, PODEMOS TENTAR TRABALHAR COM A MENOR QUANTIDADE POSSÍVEL DE CIRCUITOS NUM ÚNICO ELETRODUTO PARA ECONOMIZAR NA FIAÇÃO. PORÉM NEM SEMPRE VAMOS CONSEGUIR DISTRIBUIR MUITAS TUBUALAÇÕES POR INÚMEROS FATORES FÍSICOS DA LAJE OU CORTES DEMAIS EM PAREDES AUMENTANTO OUTROS CUSTOS. UM CIRCUITO ELÉTRICO É UM SISTEMA FECHADO DE ELEMENTOS INTERLIGADOS QUE PERMITE A PASSAGEM DE CORRENTE ELÉTRICA. É COMPOSTO POR UMA FONTE DE ENERGIA, CONDUTORES, EQUIPAMENTOS ELÉTRICOS E CONTROLE (PROTEÇÃO,SECCIONAMENTO ETC.) FONTE DE ENERGIA: SOLAR, HIDROELÉTRICA, EÓLICA, BATERIAS, GERADORES A DIESEL, ETC. CONDUTORES: CABOS ELÉTRICOS EQUIPAMENTOS: LÂMPADAS, MOTORES, CHUVEIRO, TV ETC. CONTROLE E PROTEÇÃO: INTERRUPTOR, RELÉS, DISJUNTORES, DR, ETC. EXEMPLO DE UM CIRCUITO ELÉTRICO CALCULANDO A FIAÇÃO PARA EQUIPAMENT OS ELÉTRICOS: CRITÉRIOS PARA SEPARAÇÃO DE CIRCUITOS ELÉTRICOS CONFORME NBR-5410 10A DEVE-SE ADOTAR PELO MENOS 2 CIRCUITOS PARA COZINHA CIRCUITOS DE ILUMINÇÃO E TOMADAS DEVEM SER SEPARADOS PARA ÁREAS MOLHADAS, DEVE UTILIZAR O DISPOSITIVO IDR COMO PROTEÇÃO COMPLEMENTAR. POR QUESTÕES DE BOA PRÁTICA, NO DIMENSIONAMENTO DE CIRCUITOS ELÉTRICOS, RECOMENDAMOS SEPARAR OS SEGUINTES CIRCUITOS TORNANDO UMA TUE (TOMADA DE USO ESPECÍFICO): AR CONDICIONADO AQUECEDORES DE AMBIENTE BOMBAS DÁGUA ETC. EXEMPLO: AR CONDICIONADO 10.000BTUS=1350W/220V=6.13A NOTA: EM CASO DE MANUTENÇÃO DE UM AR CONDICIONADO, SERÁ NECESSÁRIO O DESLIGAMENTO DO DISJUNTOR, E CASO O CIRCUITO ESTEJA JUNTO AS TOMADA DO QUARTO POR EXEMPLO, O CLIENTE FICARÁ SEM AS TOMADAS DO QUARTO FUNCIONANDO. DEMAIS EQUIPAMENTOS COMO FORNO, FOGÃO A INDUÇÃO, CHUVEIRO JÁ TEM A OBRIGAÇÃO DESER INSTALADO NUM ÚNICO CIRCUITO CONFORME A NBR 5410 POIS EXCEDE A POTÊNCIA MÍNIMA PARA EQUIPAMENTOS AGRUPADO NUM ÚNICO CIRCUITO. DEFINIÇÃO DE CRITÉRIO DO CABO DOS CIRCUITOS ELÉTRICOS INFORMAÇÕE S COMPLEMENT ARES DE UM PROJETO: