Machinery Watch/ECRT Casualty Control Procedures PDF

Summary

This document outlines procedures for handling various machinery incidents, detailing controlling actions, immediate actions, and supplementary actions for different casualty types. The document provides specific instructions for situations like fires in diesel generators or propulsion turbine modules. It also mentions additional actions like securing fire boundaries, desmoking affected spaces, and investigating causes.

Full Transcript

**Machinery Watch/ECRT Casualty Control** **\ ** **TABLE OF CONTENTS** A Charlie Fire in Ships Service Diesel Generator CCFG ---- ----------------------------------------------------- ------- B Charlie Fire in a Switchboard CCFS C Bravo· Fire in Pro...

**Machinery Watch/ECRT Casualty Control** **\ ** **TABLE OF CONTENTS** A Charlie Fire in Ships Service Diesel Generator CCFG ---- ----------------------------------------------------- ------- B Charlie Fire in a Switchboard CCFS C Bravo· Fire in Propulsion Turbine Module BGTM D Gas Turbine Module Cooling Air System Failure CASF E Gas. Generator Overspeeds GGOS F Gas Generator Stall GGS G MPDE Crankcase Explosion DECE H MPDE Governor Malfunction DEGM I SSDG Crankcase Explosion DGCE J MPDE Overheating DGEO K Hot Bearing in SSDG DGHB L SSDG Overheating DGOH M Excessive Propulsion Turbine Vibration EPTV N Hot Bearing in Main Reduction HBRG O Hot Line Shaft Bearing HLSB P High Power Turbine Inlet Gas Temperature HTIT Q Loss of Controllable Pitch Propeller LCRP R Loss of Digital Fuel Control LDFC S MPDE Loss of Fuel Oil Pressure LFOP T Loss of SSDG Fuel Oil Pressure LFOPD U Loss of Gas Turbine Fuel Oil Pressure LFOPT V Major Leak CPP Hydraulic Oil System LHOL W Loss of CPP Hydraulic Oil System LHOP X Major Lube Oil Leak LLOL Y MPDE Loss of Lube Oil Pressure LLOP Z Loss of SSDG Lube Oil Pressure LLOPD A1 Loss of Lube Oil Pressure to Red/CC Gear LLOPR B1 Loss of Machinery Control/Monitoring System LMCMS C1 Loss of Machinery Control/Monitoring System LMCMS D1 Gas Turbine Lube Oil Supply Pressure Low LPTO E1 Loss of Steering Control LSC F1 Loss of SSDG LSSG G1 Major Fuel Oil Leak MFOL H1 Unusual Noise or Vibration in SSDG NVDG I1 Unusual Noise or Vibration in MPDE NVME J1 Unusual Noise or Vibration in Red. Gear or Shafting NVRG K1 Post Shutdown Fire in Propulsion Turbine PSFP L1 Power Turbine Overspeeds PTOS M1 Setting Emergency Ahead Pitch SEAR +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | A. When detected, Machinery | | | Watch emergency stop | | | affected SSDG and report | | | to EOW, \"Class CHARLIE | | | fire No. [ ] | | | SSDG. No. [ ] | | | SSDG emergency stopped.\" | | | | | | B. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | C. Shoulder EEBDs. | | | | | | D. Secure generator heater | | | at local switchboard. | | | | | | E. When ordered, Duty | | | Electrician electrically | | | isolate affected SSDG and | | | report to EOW, \"No. [ | | | ] SSDG | | | electrically isolated.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | F. When required, set fire | | | boundaries as required, and | | | report to | | | | | | | | | | | | G. If it is determined that the | | | fire has self extinguished | | | after electrical isolation, | | | proceed to step H. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ -- -- -- -- +-----------------------------------+-----------------------------------+ | H. Man firefighting equipment | | | and combat Class Charlie | | | fire. Attack any fire that | | | spreads beyond the affected | | | generator. | | | | | | I. When the fire has been | | | extinguished, standby while | | | affected generator cools and | | | do **[not]** open | | | or remove generator panels. | | | | | | J. Report, \"Fire appears to be | | | out in No. [ ] | | | SSDG. Reflash watch is set.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | | | | | | | A. When the area is cool enough | | | to access | | | **[without]** | | | risk of injury, enter IAW | | | NSTM 300 for working on | | | deranged equipment. Verify | | | all circuits are de-energized | | | prior to entry. Verify that | | | fire is out, conduct | | | inspection to ensure the fire | | | is completely extinguished. | | | | | | B. Report to EOW, \"Class | | | CHARLIE fire in No. [ | | | ] SSDG is out.\" | | | | | | C. When ordered, secure | | | established fire boundaries | | | and report to EOW, \"Fire | | | boundaries secured.\" | | | | | | D. When load shedding occurred, | | | reset and close load shed | | | breakers. | | | | | | E. When required, restart all | | | | | | | | | | | | F. When required, restore | | | ventilation. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | G. When ordered, desmoke | | | affected space with installed | | | equipment. | | | | | | H. When affected space has been | | | desmoked, report to EOW, \" [ | | | ] (affected | | | space) desmoked.\" | | | | | | I. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | J. Report to EOW cause of | | | casualty and estimated time | | | for repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, restore | | | from the casualty (CP NO. | | | RCFG). | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ -- -- +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | B. When detected, Machinery | | | Watch emergency stop | | | affected SSDG and report | | | to EOW, \"Class CHARLIE | | | fire No. [ ] | | | switchboard. No. [ | | | ] SSDG | | | emergency stopped.\" | | | | | | C. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | D. Machinery Watch/ECRT/Duty | | | Electrician shoulder | | | EEBDs. | | | | | | E. When ordered, Duty | | | Electrician electrically | | | isolate the affected | | | switchboard, and report | | | to EOW, \"No. [ | | | ] switchboard | | | is electrically | | | isolated.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | E. After switchboard is reported | | | isolated and fire appears to | | | be out, standby while | | | affected | | | | | | | | | | | | F. If it is determined that the | | | fire has self extinguished | | | after electrical isolation, | | | report to EOW, \"Class | | | CHARLIE fire No. [ | | | ] switchboard | | | appears to be out.\" | | | | | | | | | | | | G. When required, secure fuel | | | oil conditioning module. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | H. Man firefighting equipment | | | and combat Class Charlie | | | fire. | | | | | | I. Report to EOW, \"Class | | | CHARLIE fire in No. [ | | | ] switchboard is | | | **[not]** | | | extinguished, continuing with | | | fire fighting effort.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | J. When the fire has been | | | extinguished, ECRT standby | | | while affected switchboard | | | cools and do | | | **[not]** open or | | | remove switchboard panels. | | | | | | K. Set reflash watch when fire | | | is verified out. | | | | | | L. Report to EOW, \"Class | | | CHARLIE fire No. [ | | | ] switchboard is | | | out and reflash watch is set. | | | | | | | | | | | | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | A. When load shedding | | | occurred, reset and close | | | load shed breakers. | | | | | | B. When required, restart | | | all | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | C. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | D. When required, restore | | | ventilation. | | | | | | E. When ordered, desmoke | | | affected space with installed | | | equipment. | | | | | | F. When affected space has been | | | desmoked, report to EOW, \" [ | | | ] (affected | | | space) desmoked.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | G. When ordered, Duty | | | Electrician tag affected | | | switchboard bus tie and SSDG | | | circuit breakers open and | | | rack out and tag open | | | unaffected switchboard bus | | | tie breakers that feed the | | | affected switchboard. | | | | | | H. Duty Electrician report to | | | EOW, "Affected switchboard | | | bus tie and SSDG circuit | | | breakers tagged open and | | | unaffected switchboard bus | | | tie breakers are racked out | | | and tagged open." | | | | | | I. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | J. Report to EOW cause of the | | | casualty and estimated time | | | to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, restore | | | from the casualty (CP NO. | | | RCFS). | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ -- -- +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | | | | | | | B. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | C. Shoulder EEBDs. | | | | | | D. Report status of module fire | | | to EOW. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | D. Shut the synthetic lube oil | | | inlet valve. | | | | | | E. Pplace the hydraulic start | | | module main power ON/OFF | | | selector switch to the OFF | | | position. | | | | | | F. Place the fuel oil | | | conditioning module main | | | power ON/OFF selector switch | | | to the OFF position. | | | | | | G. When ordered, man | | | firefighting equipment. | | | | | | H. Monitor module fire through | | | observation window. Report to | | | EOW, \"Fire is out in GT | | | module and reflash watch is | | | set.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | A. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | | | | | | | B. When ordered, enter module | | | using CP NO. GTMI and | | | investigate for fuel/lube oil | | | leaks. | | | | | | C. Report to EOW, fuel/lube oil | | | leaks/**[no]** | | | leaks in module. | | | | | | D. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | E. Report to EOW cause of the | | | casualty and estimated time | | | to repair. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, restore | | | from casualty as | | | directed. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | | | | | | | B. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | | | | | | | A. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | | | | | | | B. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | C. Report to EOW cause of the | | | casualty and estimated time | | | to repair. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, restore | | | from casualty as | | | directed. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | | | | | | | A. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | B. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | C. Report to EOW cause of the | | | casualty and estimated time | | | to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | D. When ordered, restore | | | from casualty as | | | directed. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | | | | | | | B. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | A. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | B. When ordered, investigate for | | | the cause of the casualty | | | using | | | | | | | | | | | | C. Report to EOW the cause of | | | the casualty and estimated | | | time to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. Restore from casualty as | | | ordered. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | B. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | III. [SUPPLEMENTARY | | | ACTIONS] | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | C. Investigate for system | | | integrity and report to EOW, | | | \"Systems | | | intact/**[not]** | | | intact.\" | | | | | | D. Isolate fuel oil to affected | | | MPDE. Report to EOW, \"Fuel | | | oil supply to No. MPDE | | | isolated.\" | | | | | | | | | | | | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | A. Perform preliminary | | | investigation for cause | | | of the casualty, check | | | the following: | | | | | | 1. Take MPDE lube oil | | | sample and test for | | | fuel oil dilution. | | | | | | 2. Conduct external | | | check of MPDE in | | | vicinity of | | | explosion. | | | | | | | | | | | | B. Report to EOW cause of the | | | casualty was | | | **[not]** | | | determined by preliminary | | | investigation. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | | | | | | | B. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | C. Shoulder EEBDs. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | C. When ordered, investigate for | | | cause of casualty using | | | approved maintenance | | | procedures and technical | | | manuals. | | | | | | D. Report to EOW cause of the | | | casualty and estimated time | | | to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. This casualty is | | | **[non]**-res | | | torable. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | A. Perform preliminary | | | investigation to | | | determine cause of the | | | casualty, check for the | | | following: | | | | | | 1. Governor connections | | | for loose fittings. | | | | | | 2. Actuator mechanical | | | linkages. | | | | | | 3. Injector racks for | | | erratic movement, | | | binding or loose | | | fittings. | | | | | | | | | | | | B. Report to EOW cause of the | | | casualty was | | | **[not]** | | | determined by preliminary | | | investigation. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. When ordered report to [ | | | ] space. | | | | | | B. Investigate primary | | | governor failure of | | | affected MPDE. | | | | | | | | | | | | II. [IMMEDIATE | | | ACTIONS] | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | C. When ordered, investigate for | | | cause of casualty using | | | approved maintenance | | | procedures and technical | | | manuals. | | | | | | D. Report to EOW cause of the | | | casualty and estimated time | | | to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, test No. [ | | | ] MPDE using | | | approved test procedures | | | and technical manuals. | | | | | | B. Report to EOW, \"No. [ | | | ] MPDE tested | | | satisfactory and is ready | | | for operation.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | A. Machinery Watch emergency | | | stop affected SSDG and report | | | to EOW, \"Crankcase explosion | | | No. [ ] SSDG. No. | | | [ ] SSDG | | | emergency stopped.\" | | | | | | B. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | C. Shoulder EEBDs. | | | | | | | | | | | | D. Investigate for system | | | integrity and report to EOW, | | | \"systems | | | intact/**[not]** | | | intact.\" | | | | | | E. Isolate fuel oil to affected | | | SSDG and report to EOW, | | | \"SSDG fuel oil system | | | isolated.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | A. When automatic load | | | shedding has occurred, | | | reset and close load shed | | | breakers. | | | | | | B. When required restart all | | | **[non]**-vit | | | al | | | and semi-vital equipment. | | | | | | | | | | | | C. When ordered, investigate | | | cause of casualty as follows: | | | | | | 1. Conduct external check of | | | SSDG in vicinity of | | | explosion. | | | | | | 2. Take lube oil sample and | | | test for fuel oil | | | dilution. | | | | | | | | | | | | D. Report to EOW, cause of | | | casualty was | | | **[not]** | | | determined by preliminary | | | investigation. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | E. When ordered, investigate for | | | cause of casualty using | | | approved maintenance | | | procedures and technical | | | manuals. | | | | | | F. Report to EOW, cause of | | | casualty and estimated time | | | to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. This casualty is | | | **[non]**-res | | | torable. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | | | | | | | B. Investigate for system | | | integrity. Report to EOW, | | | "system | | | intact/**[not]** | | | intact.\" | | | | | | | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | C. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | D. Perform preliminary | | | investigation to | | | determine cause of the | | | casualty. Check the | | | following: | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | 1. Jacket water expansion tank | | | for proper water level. | | | | | | 2. Coolant thermostat for proper | | | operation. | | | | | | 3. Jacket water system for | | | proper alignment/operation. | | | | | | 4. Seawater cooling system | | | alignment/operation. | | | | | | 5. Inspect seawater cooling | | | strainer(s). | | | | | | 6. Engine lube oil sump level. | | | | | | 7. Lube oil sample taken. | | | | | | | | | | | | B. Report to EOW, cause of | | | casualty was | | | **[not]** | | | determined by preliminary | | | investigation. | | | | | | C. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | D. Report to EOW, cause of | | | casualty and estimated time | | | to repair. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, test No. [ | | | ] MPDE using | | | approved test procedures | | | and technical manuals. | | | | | | B. Report to EOW, \"No. [ | | | ] MPDE tested | | | satisfactory and is ready | | | for operation.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | | | | | | | A. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | B. Monitor hot bearing on | | | affected SSDG. Report | | | condition of affected SSDG | | | bearing to EOW. | | | | | | C. When bearing temperature | | | remains above normal limits | | | or is determined | | | uncontrollable, proceed to | | | IMMEDIATE ACTIONS. | | | | | | | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | D. When ordered, emergency | | | stop affected SSDG. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | A. When automatic load | | | shedding has occurred, | | | reset and close load shed | | | breakers. | | | | | | B. When required, restart | | | all | | | | | | | | | | | | C. When ordered, investigate for | | | cause of the casualty using | | | | | | | | | | | | D. Report to EOW, cause of the | | | casualty and estimated time | | | to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | E. When ordered, test No. [ | | | ] SSDG in | | | accordance with approved | | | maintenance procedures | | | and technical manuals. | | | | | | F. Report to EOW, \"No. [ | | | ] SSDG tested | | | satisfactory and ready | | | for operation.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | | | | | | | A. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | B. When ordered, align affected | | | SSDG emergency cooling (No. 3 | | | SSDG only), monitor jacket | | | water temperature. | | | | | | C. Report to EOW, \"SSDG | | | emergency cooling aligned | | | (No. 3 SSDG only), jacket | | | water temperature | | | increasing/decreasing.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | II. [IMMEDIATE | | | ACTIONS] | | | | | | | | | | | | A. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | B. When jacket water temperature | | | rises above 225QF, emergency | | | stop affected SSDG. | | | | | | C. Report to EOW, \"No. [ | | | ] SSDG | | | overheating uncontrollable, | | | emergency stopped No. [ | | | ] SSDG.\" | | | | | | | | | | | | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | D. When automatic load | | | shedding has occurred, | | | reset and close load shed | | | breakers. | | | | | | E. When required, restart | | | all | | | | | | | | | | | | F. When ordered, investigate for | | | cause of casualty as follows: | | | | | | 1. Inspect seachest | | | strainers. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | 2. Seawater pump for proper | | | operation. | | | | | | 3. Seawater cooling system | | | alignment. | | | | | | 4. Jacket water expansion tank | | | level. | | | | | | 5. Jacket cooling water system | | | alignment. | | | | | | 6. Vent heat exchangers, | | | jacketwater and seawater | | | pumps/system. | | | | | | 7. Take jacket water sample. | | | | | | 8. Take lube oil sample. | | | | | | | | | | | | D. Report to EOW cause of | | | casualty was | | | **[not]** | | | determined by preliminary | | | investigation. | | | | | | E. When ordered, investigate for | | | cause of casualty using | | | approved maintenance | | | procedures and technical | | | manuals. | | | | | | F. Report to EOW cause of | | | casualty and estimated time | | | to repair. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | IV. [RESTORE | | | CASUALTY] | | | | | | A. When ordered, test No. [ | | | ] SSDG in | | | accordance with approved | | | maintenance procedures | | | and technical manuals. | | | | | | B. Report to EOW, \"No. [ | | | ] SSDG tested | | | satisfactory and ready | | | for operation.\" | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. None. | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | B. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | III. [SUPPLEMENTARY | | | ACTIONS] | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | A. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | B. When ordered, investigate for | | | the cause of the casualty | | | using | | | | | | | | | | | | C. Report to EOW the cause of | | | the casualty and estimated | | | time to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. Restore from casualty as | | | directed by EOW. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | A. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | | | | | | | B. When the EOW identifies the | | | hot bearing inspect for any | | | unusual conditions. | | | | | | C. Report to EOW any unusual | | | conditions noted during | | | inspection. | | | | | | D. Perform the following: | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | 1. Verify lube oil cooler | | | alignment and system | | | intact/**[not]** | | | intact. | | | | | | 2. Draw and retain lube | | | | | | | | | | | | 3. Sample and inspect lube oil | | | cooler, oilside and | | | waterside, for possible | | | contamination or leaks. | | | | | | 4. Shift lube oil filter(s). | | | | | | 5. When required, adjust the | | | lube oil cooler outlet | | | temperature as required, to | | | lower lube oil header | | | temperature. | | | | | | | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | A. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | III. [SUPPLEMENTARY | | | ACTIONS] | | | | | | 0 | | | | | | A. When required and when | | | ordered, perform emergency | | | cooldown on GT. | | | | | | B. Perform preliminary | | | investigation to determine | | | cause of the casualty. Check | | | for the following: | | | | | | 1. Insufficient lube oil | | | sump level. | | | | | | 2. Water in the lube oil. | | | | | | 3. Proper lube oil cooler | | | alignment. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | 4. Contaminated lube oil cooler | | | oilside and watersides. | | | | | | 5. Clogged lube oil filter(s). | | | | | | | | | | | | C. Report to EOW cause of the | | | casualty was | | | **[not]** | | | determined by preliminary | | | investigation. | | | | | | D. When ordered, investigate for | | | the cause of the casualty | | | using the approved | | | maintenance procedures and | | | technical manuals. | | | | | | E. Report to EOW the cause of | | | the casualty and estimated | | | time to repair. | | | | | | | | | | | | IV. [RESTORE | | | CASUALTY] | | | | | | A. Restore the casualty as | | | directed by the EOW. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+-----------------------------------+ | I. [CONTROLLING | | | ACTIONS] | | | | | | | | | | | | A. When ordered, report to [ | | | ] (location) and | | | establish communications with | | | EOW. | | | | | | B. If line shaft bearing | | | temperature does | | | **[not]** | | | stabilize and bearing | | | temperature continues to | | | increase, proceed to | | | IMMEDIATE ACTIONS. | | | | | | | | | | | | II. [IMMEDIATE | | | ACTIONS] | | | | | | C. When ordered, report to [ | | | ] (location) | | | and establish | | | communications with EOW. | | | | | | D. When ordered, attempt to | | | bar over main engine | | | until lube oil sump | | | temperature drops below | | | 1800F. | | +-----------------------------------+-----------------------------------+ | | | +-----------------------------------+----------------------------------

Use Quizgecko on...
Browser
Browser