BAL_1800124_03_001_1_EN.pdf

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...

Transcript

www.reinhausen.com On-load tap-changer VACUTAP® VT Technical Data TD 124/03 2 TD 124/02 124/02/01/0 Contents Contents 1 General....................................................................................................

www.reinhausen.com On-load tap-changer VACUTAP® VT Technical Data TD 124/03 2 TD 124/02 124/02/01/0 Contents Contents 1 General.................................................................................................................................................................................................................. 4 1.1 Summary of technical data................................................................................................................................................................ 4 2 Technical Data.................................................................................................................................................................................................. 5 2.1 Rated through-current (Iu), rated step voltage Ui, rated switching capacity (PStN)....................................................... 5 2.2 Contact life.............................................................................................................................................................................................. 5 3 Appendix............................................................................................................................................................................................................... 6 NOTE These technical data are intended for the calculator and designer of the transformer. These type-specific data are only valid in connection with the information contained in the general section (TD 61) since this section contains important information on such subjects as potential connection, leakage inductance, current division, and so on. Dimensional drawings and connection diagrams are subject to change without prior notice. Drawings submitted during bidding and ordering are always binding. Since the on-load tap-changer is delivered to the specifications of the transformer manufacturer, the transformer manufacturer is responsible for selecting the correct properties of the on-load tap-changer so that the requirements of the transformer are met. 124/03/01/0 TD 124/03 3 1 General 1 General 1.1 Summary of technical data The on-load tap-changers in all their specifications are subject to all relevant international and national guidelines and standards, particularly IEC Publication 60214 3ED 89 and the VDE standard DIN EN 60214 (VDE 0532 Teil 30): 1998-06. On-load tap-changer VT I 500 3 x VT I 500 Number of poles 1 3 Max. rated through-current Ium (A) 500 Rated short-time withstand current, r.m.s. value (kA) 5 Rated short-circuit duration (s) 3 Rated peak withstand current (kA) 12.5 Max. rated step voltage Uim (V) 900 Step capacity (PStN) kVA 250 Operating positions max. 9, no change-over selector available Rated frequency (Hz) 50... 60 Rated insulation level Highest voltage for equipment Um (kV) 40.5 Rated lightning impulse withstand voltage to ground and 200 between phases (for VT I 500 only to ground) kV, 1.2I50 µs Rated AC withstand voltage to ground and 85 between phases (for VT I 500 only to ground) kV, 50 Hz, 1 min Rated lightning impulse withstand voltage between any 20 two adjacent contacts of the tap selector (kV, 1.2I50 µs) Rated AC withstand voltage between any two adjacent 5 contacts of the tap selector (kV, 50 Hz, 1 min) Rated lightning impulse withstand voltage between the first 80 and last contacts of the tap selector (kV, 1.2I50 µs) Rated AC withstand voltage between the first and last contacts 20 of the tap selector (kV, 50 Hz, 1 min) Installation position vertical, attachment of the on-load tap-changer is provided on top only Environmental medium air Operating conditions (ambient class E0 in acc. with IEC 60076-11) indoor installation; max. 1000 m amsl Ambient temperature Can be operated in the rated load range at temperatures of –25 °C to +65 °C Frequency of operation max. 1 switching operation per minute Running time per operation in s (with motor drive unit ED) 5.3 Weight (kg) ca. 70 ca. 210 Drive mechanism Motor drive unit ED, protective housing in outdoor design, motor for 3 AC 230/400 V,50 Hz, 0.75 kW, step-by-step operation with local/remote control, electrical/mechanical end position limit, connection facility for remote position indication, hand crank for adjustment purposes and emergency operation 4 TD 124/03 124/03/01/0 2 Technical Data 2 Technical Data 2.1 Rated through-current (Iu), rated step voltage (Ui), rated step capacity (PStN) On-load tap-changer Rated through-current Iu (in A) 280 500 Relevant rated step voltage Ui (in V) 900 500 Step capacity PStN (in kVA) 250 250 Table Rated through-currents (Iu), relevant rated step voltages (Ui) and rated switching capacity (PStN), at highest and lowest rated step voltage of the step capacity curve (see fig. 1). Ui, (V) 8985633E Fig.1 Rated step capacity (Iu, Ui) Iu (A) 2.2 Contact life The contact life of the vacuum interrupters amounts to 200.000 switching operations, regardless of step voltage and through-current. After 200.000 switching operations, the vacuum interrupters have to be replaced. 124/03/01/0 TD 124/03 5 3 Appendix 3 Appendix On-load tap-changer VACUTAP® VT I 500, installation drawing............................................................................................................ 898312 On-load tap-changer VACUTAP® VT I 500, dimension drawing.............................................................................................................. 897979 On-load tap-changer VACUTAP® VT I 500, switching sequence............................................................................................................. 899507 Motor drive unit ED-S, protective housing................................................................................................................................................... 898801 Bevel gear CD 6400, dimension drawing........................................................................................................................................................ 892916 Motor drive unit ED-S with CD 6400, limit dimensions of vertical drive shaft................................................................................. 898598 On-load tap-changer VACUTAP® VT I 500, drive shaft arrangements.................................................................................................. 897377 On-load tap-changer VACUTAP® VT I 500, adjustment plan................................................................................................................... 898613 On-load tap-changer VACUTAP® VT I 500, determination of the insulating shaft length............................................................ 897975 On-load tap-changer VACUTAP® VT I 500, connection diagrams.......................................................................................................... ZS010157 6 TD 124/03 124/03/01/0 On-load tap-changer VACUTAP® VT I 500 8983123E Installation drawing 124/03/01/0 TD 124/03 7 On-load tap-changer VACUTAP® VT I 500 8979794E Dimension drawing 8 TD 124/03 124/03/01/0 On-load tap-changer VACUTAP® VT I 500 8995070E Switching sequence 124/03/01/0 TD 124/03 9 Motor-drive unit ED-S 8988012E Protective housing Vertical guard plate with spacing ring Hand crank * for design with intermediate bearing 3 dummy plates for packing glands special design with OLTC monitoring required Wall of transformer tank Shim Attachment of protective housing The cover can be opened to the left or to the right depending on the arrange- ca. 690 if opened 130° ment of the hinge pins. ca. 864 if opened 180° Aperture of fixing holes on protective housing Aperture in protective housing for cables (rear view) (underside view) 10 TD 124/03 124/03/01/0 Bevel gear CD 6400 8929167M Dimension drawing 124/03/01/0 TD 124/03 11 Motor-drive unit ED with CD 6400 8985981E Limit dimensions of vertical drive shaft 12 TD 124/03 124/03/01/0 On-load tap-changer VACUTAP® VT I 500 8973776E Drive shaft arrangements 124/03/01/0 TD 124/03 13 On-load tap-changer VACUTAP® VT I 500 8986134E Adjustment plan 14 TD 124/03 124/03/01/0 On-load tap-changer VACUTAP® VT I 500 8979754E Determination of the insulating shaft length 124/03/01/0 TD 124/03 15 On-load tap-changer VACUTAP® VT I 500 ZS010157 Connection diagrams - 16 TD 124/03 124/03/01/0 © Maschinenfabrik Reinhausen GmbH Phone +49 941 40 90-0 www.reinhausen.com Falkensteinstrasse 8 Fax +49 941 40 90-7001 93059 Regensburg, Germany E-Mail [email protected] Please note: The data in our publications may differ from the data of the devices delivered. We reserve the right to make changes without notice. TD 124/03 en 01/17 F0020202 Printed in Germany

Tags

technical specifications electrical engineering transformers
Use Quizgecko on...
Browser
Browser