Railway Electric Traction - RDSO Specifications PDF

Summary

This document is a section of a technical manual, providing specifications and drawings for railway electric traction, focusing on overhead equipment. It includes details on various components and materials, such as copper conductors, insulators, and support structures.

Full Transcript

APPENDIX - IX LIST OF SPECIFICATIONS AND DRAWINGS FOR EQUIPMENTS AND MATERIALS FOR RAILWAY ELECTRIC TRACTION CHAPTER – I RDSO SPECIFICATIONS SECTION – I – OVERHEAD EQUIPMENT 1. Conventional OHE (Cd Cu Catenary + Cu C...

APPENDIX - IX LIST OF SPECIFICATIONS AND DRAWINGS FOR EQUIPMENTS AND MATERIALS FOR RAILWAY ELECTRIC TRACTION CHAPTER – I RDSO SPECIFICATIONS SECTION – I – OVERHEAD EQUIPMENT 1. Conventional OHE (Cd Cu Catenary + Cu Contact wire ) SN Specification No. Amend Subject Remarks 1. ETI/OHE/3(1/83) 2(2/85) Annealed standard copper conductor for jumper wire. 2. RE/30/OHE/5(11/60) Copper busbar 3. RE/OHE/10(3/66) Splices and ending clamps. Withdrawn 4. ETI/OHE/11(5/89) Steel tubes. 5. ETI/OHE/13(4/84) 3(4/90) Hot dip zinc coating on steel masts (rolled and fabricated), tubes & fittings used on 25 Kv ac OHE. 6. ETI/OHE/14(7/86) 1(9/89) Stainless steel wire rope 7. ETI/OHE/15(9/91) Solid core porcelain insulators for 25 kV 50 Hz. Overhead lines. 8. ETI/OHE/16(9/84) 25 kV single and double pole isolators. 9. ETI/OHE/18(4/84) 3(9/87) Steel and stainless steel bolts nuts and washers. 10. ETI/OHE/21(9/74) Aluminum alloy section and tubes. 11. RE/OHE/22(9/61) Dynamometers. 12. RE/OHE/23(9/61) Pull lifts 13. RE/OHE/25(3/66) Standard for drawing for traction. 14. ETI/OHE/27(8/84) Standard insulator Assembly Without sectioning insulator 15. RE/OHE/28(3/72) Double wire section insulator Obsolete 16. ETI/OHE/33(8/85) Enamelled steel plates 17. ETI/OHE/36(12/73) Galvanized steel wire 18. ETI/OHE/37(12/73) Hard drawn copper catenary For WKR 19. ETI/OHE/42(2/92) Hard drawn grooved copper contact wire for ac electric traction. 20. ETI/OHE/44(7/78) PVC hand rail covering used Withdrawn for traction bond. (VideETI Dt 18/19.7.84 21. ETI/OHE/48(7/84) 1(9/87) Winch type regulating equipment for 25 kV ac traction. 22. ETI/OHE/48a(9/85) 1(11/87) Three pulley type regula- ting equipment (3:1 Ratio) 23. ETI/OHE/49(5/84) 5(4/90) Fittings for 25 kV ac OHE INDIAN RAILWAY- AC TRACTION MANUAL-VOLII-PARTII 24. ETI/OHE/50(8/83) 4(12/93) Cadmium copper conductor for overhead/railway traction 25. ETI/OHE/51(9/87) Discharge/earthing pole assembly for 25 kV ac traction. 26. ETI/OHE/52(10/84) Interlock for ac traction switchgears. 27. ETI/OHE/53(6/88) 3(6/90) Principles for OHE layout plans and sectioning diagrams for 25 kV ac traction. 28. ETI/OHE/56(5/85) 1(12/89) Contact wire manufactured from Withdrawn Continuous cast hot rolled electro vide lytic copper wire rods. ETI/OHE/CC/1/4 Dt.11.4.99 29. ETI/OHE/59(12/90) 4(10/91) Tender specifications of 8 wheeler OHE Inspection Car. 30. ETI/OHE/63(5/91) Short neutral section assembly ( Phase break) 31/ ETI/OHE/64(10/88) 1(9/89) Solid core cylindrical post insul ator system with nominal voltage of 220, 132, 110 and 66 kV. 32. EI/OHE/65(8/87) 2(4/90) Continuous cast wire rods. 33. ETI/OHE68(11/87) Polymer insulators for 25 kV single phase 50 Hz. Overhead traction line. 34. ETI/OHE/69(12/87) Toughened Glass Insulators. 35. ETI/OHE/70(10/88) Rubber mat for use below overline Structure in the 25 kV ac,50 Hz. Single phase electric traction areas. 36. ETI/OHE/71(11/90) 1(8/91) Code for bonding & Earthing for kV, single phase, 50 Hz., ac Traction System. 37. ETI/OHE/72(11/91) For axle car for winding and/or unwinding of contact wire & catenary wire. 2. Aluminum OHE SN. Specification No. Amend Subject Remarks 1. ETI/OHE/54(2/85) 1(11/89) 19/2.79mm all Al. Alloy standard catenary wire. 2. ETI/OHE/55(4/90) Bimetallic (Al-Cu) strip for kV traction OHE. 3. AL OHE/101 (8/83) Al. Alloy grooved contact wire 16.4 mm dia 193/190 mm2 cross section. 3. Civil SN. Specification No. AmendSubject Remarks 1. ETI/C/1(1/80) Standard code of practice Not to be painting of rolled steel used. electrification mast. 2. ETI/C2(1/82) Indian Rly. Standard Spe- cification for Prestressed concrete (spun type) OHE traction masts. 3. ETI/C/3(5/83) Indian Rly. Standard spec- ification for spraying zinc coating on the OHE masts. 4. ETI/C/4(5/88) Draft Indian Rly. Standard specification for cold roll formed mast for Railway electrification. 5. ETI/C/4(5/88) Specification for FLO-COAT STEEL TUBES. INDIAN RAILWAYS-AC TRACTION MANUAL-VOLII-PARTII CHAPTER – I RDSO SPECIFICATIONS SECTION – II – POWER SUPPLY INSTALLATION. 1. 25 kV ac System SN. SPECIFICATION NO. Amend Subject Remarks 1. ETI/PSI/1 (6/81) Battery charger for 110 volt battery, 40 Ah. 2. ETI/PSI/3(8/75) Lightning Arrestor, 7.5 kV 3. ETI/PSI/4(9/79) Interruptors, 25 kV. Obsolete 4. ETI/PSI/8(12/79) Potential Transformers, 25KV. Superseded by ETI/PSI 134(8/89) 5. ETI/PSI/11(12/81) Single pole circuit breakers,25KV Obsolete 6. ETI/PSI/13(3/85) Booster transformer, 25 kV Obsolete 7. ETI/PSI/14(1/86) 25 kV Dropout fuse switch and operating pole. 8. ETI/PSI15(10/73) 25 KV/240 V LT supply Add. Slipno.3 = 2(3/89) transformer 10 KVA (12/81) applicable in case of seal type 9. ETI/PSI/15A(7/82) 25KV/240V LT supply trans- formers, 100 KVA 10. ETI/PSI/17(1/72) Admittance relay for 25KV 11. ETI/PSI/18(8/75) Lightning Arrestor, 120KV. Superseded by ETI/PSI137(8/89) 12 ETI/PSI/19(7/85) Lightning Arrester, Valvetype 42 kV, Station class. 13. ETI/PSI/20(6/79) Double pole&Triple pole isolators, 132 kV ) 14. ETI/PSI/20A(6/79) Earthing blade assembly Superseded for double pole & Triple) by ETI/PSI Triple pole isolators, 132 kV) 122(3/89) 15. ETI/PSI/20B(7/79) Double pole & triple pole motor operated Isolators),132 kV. 16. ETI/PSI/21(6/81) Lead acid batteries 110V,400 Ah. 17. ETI/PSI23(4/72) Double pole & triple pole circuit breakers, 132KV. Obsolete 18. ETI/PSI/23A(1/73) Double pole & triple pole circuit breakers 110KV Obsolete 19. ETI/PSI/24(6/81) Battery charger for 110 V,battery, 220 Ah. 20. ETI/PSI/25(6/81) Lead acid batteries 110,200 Ah. 21. ETI/PSI/27(6/87) Rly. 1 Control & relay board for =1(4/88),2(8/88),3(4/89) railway traction sub-station. 22. ETI/PSI/29(12/79) Low tension distribution panels for railway ac traction sub-station 23. ETI/PSI/30(12/82) Lead acid batteries 24 V type I & II for RC Equipment. INDIAN RAILWAYS-AC TRACTION MANUAL-VOLII-PARTII 24. ETI/PSI/31(5/76) Standards for drawings for power supply installations 25. ETI/.PSI/35(4/75) Potential transformers, 132 kV 26. ETI/PSI/36(5/75) Current transforerm, 132 Kv, (Type II) 27. ETI/PSI/37(7/74) Battery charger type I & II for 24 V lead acid batteries for remote control equipment. 28. ETI/PSI/38(1/73) Selective frequency level meter Analyser. 29. ETI/PSI/39(5/75) Impulse recorder. 30. ETI/PSI/41(1/73) Double pole & triple pole Superseded by isolator 110 kV ETI/PSI 122(3/89) 31. ETI/PSI/42(8/75) Lightening arrestors 96 kV. Superseded by ETI/PSI 137(8/89) 32. ETI/PSI/43(10/90) Control & distribution panel for color light signalling supply 33. ETI/PSI/44(12/73) Standard for electrical distribution system in Station & Yards where kV ac traction is to be Introduced. 34. ETI/PSI/46(8/90) Single pole vacuum circuits breakers, = 3(1/92) 25 kV. 35. ETI/PSI/47(9/78) Telemetering equipment for 25 kV,ac traction. 36. ETI/PSI/50(8/79) Double pole & triple pole isolators Superseded by 66 kV ETI/PSI 122(3/89) 37. ETI/PSI/50A(8/79) Earthing blade assembly for double pole & triple pole isolators, 66KV. 38. ETI/PSI/50B(4/80) Double pole and triple pole motor operated isolators, 66 kV. 39. ETI/PSI/53(8/79) Lightning arrestors 60 kV Superseded by ETI/PSI 137(8/89) 40. ETI/PSI/56(3/80) Potential transformers, 66 kV 41. ETI/PSI/58(8/82) 400 KVA, 25 KV/415V110V single phase power transformers. 42. ETI/PSI/59(1/81) 25 kV dropout fuse switch & operating pole emergency power supply equipment. 43. ETI/PSI/61(9/86) 13.5/20 MVA (I) 132/25KV, (II) 110/25KV =36(6/88), 4(7/88) (III) 66/25 kV, Single phase, power transformer. 44. ETI/PSI/62(7/82) Insulating transformer oil purification Superseded plant (2500Ltr. Per hour capacity) work- byETI/PSI able on 230 Vlts ac single phase supply for railway ac sub-station. 103(7/89 45. ETI/PSI/63(7/82) Low tension distribution panels. 46. ETI/PSI/65(8/84) Control & relay pane board incorporating =1(9/89) static type relay for 25 kV ac traction sub- station. INDIAN RAILWAY-AC TRACTION MANUAL -VOLII PARTII 47. ETI/PSI/66(9/86) Rev II Single pole SF-6 circuit breakers 25 kV superseded by = 3(9/86 ac for railway traction sub-station ETI/PSI 43(5/87) 48. ETI/PSI/67(3/89) 25 kV shunt capacitor equipment for =4(8/91) railway traction sub-station 49. ETI/.PSI/70(11/84) Hollow porcelain insulator and bushing 50. ETI/PSI/71(1/87) Rev.I Metal oxide gapless type lightning = 4(12/91) arrestor for use on 25 kV side of Rly. Traction sub-station and switching Station. 51. ETI/PSI/73(10/88) Single pole outdoor SF-6 gas =3(1/92) interruptor for 25 kV ac traction sub-station 52. ETI/PSI/74(6/90) Single pole vacuum interruptor = 3(1/92) for 25 kV ac traction sub-stn. 53. ETI/PSI/75(8/85) 25 kV single phase series capacitor 54. ETI/PSI/76(7/890 Rev IV For SRC equipment and data superseds =1(6/90) acquisition for control of 25 kV spec. ETI/ single phase 50 Hz. Traction PSI/48(10/76) power supply 55. ETI/PSI/77(9/85) Distributed type 25 kV ac single phase series capacitor for installation at boos- ter transformer location. 56. ETI/PSI/78(4/86) 20/27 MVA, I 132/25 kV , (II) 110/25 Superseded by kV(Iii) 66/325 kV single phase power ETI/PSI 118 Transformer. (7/88) 57. ETI/PSI/79(1/87) 280 KVA, 25 kV, single phase, 50Hz = 1(9/89) oil filled conventional type booster transformer. 58. ETI/PSI/80(10/86) 25 kV 240 V dry type cast resin LT = 1(9/89) supply transformer, 10 KVA for railway ac traction sub-station. 59. ETI/PSI/81(11/86) 280 KVA, 25 kV, single phase, 50Hz dry type cast resin booster transformer 60. ETI/PSI/82(2/87) Metal Oxide gapless type lightning Superseded = 1(3/87_) arrestor for use on 132 kV side of ETI/PSI 137 railway traction sub-station (8/89) 61. ETI/PSI/83(4/87) 3.3 MVA 3 phase dry type cast epoxy resin rectifier transformer for use in DC traction sub-station. 62. ETI/PSI/84(3/87) Dry type cast resin potential transformer = 1(5/89) 25 kV for use in railway ac traction substation. 63. ETI/PSI/86(3/87) Dry cast resin type current transformer = 1(4/89) 25 kV for use in railway ac traction sub-station. 64. ETI/PSI/88(4/87) 220 kV ac double pole/triple pole isolato (Superseded by ETI/PSI/122 (3/89) 65. ETI/PSI/89(4/87) Metal oxide gapless type lightning Superseded by arrestor for use on 220 kV side of ETI/PSI/137 railway traction sub-station. (8/89) 66. ETI/PSI/90(9/87) 25 kV current transformers with ratio = 3(3/89) of (I) 1000-500 /5A (ii) 1500-750/5A INDIAN RAILWAYS-AC TRACTION MANUAL-VOLUME-II-PARTII 67. ETI/PSI/92(5/87) 100 KVA, 25 kV dry type single phase 50 Hz. Cast resin booster transformer 68. ETI/PSI/93(5/87) 25 kV ac single pole SF-6 circuit breaker = 5(1/92) for railway traction sub-station( for heavy haul train section) 69. ETI/PSI/97(6/87) 100 KVA, 25 kV single phase 50Hz. Dry = 1(9/88) type cast resin booster transformer 70. ETI/PSI/98 (6/87) 150 KVA, 25 kV single phase 50 Hz., = 1(9/88) oil filled conventional type booster transformer 71. ETI/PSI/99(6/87) Trivector meter and maximum demand indicator for railway ac traction substation. 72. ETI/PSI/100(10/.90) Specification for thyristor switched shunt capacitor equipment for railway traction sub- station. 73. ETI/PSI/101(8/87) Two zones static relay for distance protection for 25 kV ac single phase, 50 Hz traction over head equipment. 74. ETI/PSI/103(7/89) High vacuum type insulating/transformer Supersedes oil purification plant( capacity 3000 LPH) specn. No. for railway traction sub-station ETI/PSI/62 (7/82) 75. ETI/PSI/104 (9/87) Re-current surge generator for use in railway traction sub-station. 76. ETI/PSI/105(9/87) Gas chromatograph for use in analysis of dissolved gases of transformer oil. 77. ETI/PSI/106 (9/87) capacitance bridge and dissipation factor bridge for the measurement of solid insulations of insulating oil. 78. ETI/PSI/108(9/87) Power system disturbance recorder. 79. ETI/PSI/PSS/LAB/ Digital storage oscilloscope. 109(10/87) 80. ETI/PSI/PSS/LAB/110 Dual trace oscilloscope (10/87) 81. ETI/PSI/PSS/LAB/112 Digital frequency meter (10/87) 82. ETI/PSI/PSS/114(3/88) Waveform analyser 83. ETI/PSI/PSS/LAB/115 Data logger (11/87) 84. ETI/PSI/116(4/88) 220/132/110/66 kV DP/TP SF-6 7(3/92) gas circuit breaker. 85. ETI/PSI/117(7/88) Current transformer =5(6/90) I) 220 kV, 200/110/5 ii)132KV,400-200/5 iii)110 kV, 400-200/5 iv) 66KV,800-400/5 86. ETI/PSI/118(7/89 Power transformer 20 MVA single Supersedes specn = 1(3/92) phase 50Hz. 220/132/110/66 kV for No. ETI/PSI/118 traction sub-station. (7/89) 87. ETI/PSI/119(7/88) Specification for 8 channel U-Vrecorder 88. ETI/PSI/120(2/91) Code of practice for earthing of power Draft. Supply installation for 25 kV ac 50 Hz. Single phase traction system INDIAN RAILWAYS-AC TRACTION MANUAL-VOLUME-II-PARTII

Use Quizgecko on...
Browser
Browser