What are the key element to WHMIS?

  • Worker education transportation of goods and SDS
  • Transportation of dangerous goods labelling requirements in SDS
  • Worker education explosive limits and STS
  • Worker education labelling requirements and SDS (correct)

Which class of extinguishers is used to extinguish wood fire?

  • A (correct)
  • B
  • C
  • D

Refer to figure what is done to achieve zero energy status when locking out the system?

  • Drain store to pressure lock drain open on the tank then plug relief valve
  • Drain stored pressure than plug relief valve
  • Log out electrical energy then plug relief fell
  • Lock all electrical energy drain pressure then lockout drain open on tank (correct)

What is done to a power tool that has a defective firing pin?

<p>Removed from service until repaired by an authorized person (C)</p> Signup and view all the answers

How many people are able to work on a motorized platform?

<p>Equal to the maximum weight requirement (C)</p> Signup and view all the answers

Which link condition is acceptable to use on a job site?

<p>Sling with soiled and mud (D)</p> Signup and view all the answers

What are the steps to repair a brazed copper to brass joint?

<p>Measure cut clean ream flux assemble (D)</p> Signup and view all the answers

When installing a washroom when is the plumbing inspector initially called

<p>After the Rough in (A)</p> Signup and view all the answers

Given the following info 25 water closet in eight hours 15 minutes to move unit into location

<p>5 (D)</p> Signup and view all the answers

Refer to figure 29 how many 200 x 90 L balls are there

<p>2 (B)</p> Signup and view all the answers

Refer to figure 91 for a hospital lavatory installation what is the Rough in height of the fixture drain from the finished floor?

<p>556mm 21 ½ (C)</p> Signup and view all the answers

Refer to figure 11 with the allowance of 15% waist what is the minimum length of half inch pipe

<p>110' (A)</p> Signup and view all the answers

Referred to figure 98 what is the length of air if measurement of Z is 1000 mm (40“)?

<p>1132mm 45 ⅜ (C)</p> Signup and view all the answers

Refer to figure 82 reference to appendix A given the following info what is the minimum number of clevis hangers required inside the room for the horizontal including at each wall?

<p>18 (D)</p> Signup and view all the answers

What is done if the instructions by your supervisor or not clear

<p>ask supervisor to clarify instruction (B)</p> Signup and view all the answers

When installing the hydronic baseboard heating distribution system which colour code indicates the minimum type of copper to be used?

<p>red (C)</p> Signup and view all the answers

Referred to figure 22 what is the length of travel if the offset is 3 m (10’)?

<p>4.242m 14 1 ¾ (C)</p> Signup and view all the answers

Referred to figure 35 the distance between elevation a an elevation P is 3 m (10’) what is the length of the pipe that needs to be cut?

<p>2873mm 115’ (C)</p> Signup and view all the answers

Refer to figure 58 what length of copper tube is used to bend the expansion loop from point A if the gain is 9.5 mm per bend?

<p>1.232mm 48 1/2 (A)</p> Signup and view all the answers

in plumbing what angle does a flaring tool provide on a copper tubing?

<p>45 (D)</p> Signup and view all the answers

What is done to prepare copper for soldering?

<p>measure cut rheem then flux (B)</p> Signup and view all the answers

When connecting plastic water service pipe through the copper water distribution line which type of fitting is required?

Signup and view all the answers

What is the procedure to assemble a compression joint of copper tubing?

<p>Cut Rheem slide nut and feral over the tubing pushing completely into the socket then tighten nut (A)</p> Signup and view all the answers

When installing ABS pipe and fittings at -15. What is done to ensure adhesion?

<p>dilute the glue (A)</p> Signup and view all the answers

What is the procedure to assemble a hub and spigot gasket joint on plastic pipe?

<p>Cut end of pipe square, bevel end of pipe, clean pipe end and fittings, mark pipe for insertion depth, lubricate gasket and spigot, then push spigot into pipe until depth reached (A)</p> Signup and view all the answers

Refer to figure 62 What is used to join the black iron pipe to B?

<p>threaded union (B)</p> Signup and view all the answers

How is tight of loose threaded corrected?

<p>By adjusting the dies (A)</p> Signup and view all the answers

What is the change in direction with a cast iron ⅛ bend?

<p>45 (B)</p> Signup and view all the answers

How is a cast iron pipe jointed to a 4” hub in an existing system?

<p>By caulking the joint using oakum and cold caulking compound (C)</p> Signup and view all the answers

What is the procedure to cut glass?

<p>Measure mark score heat then tap (C)</p> Signup and view all the answers

What diameter pipe is requiredWith a sanitary building sewer of 830 FU and a slope of 2%?

<p>6&quot; (A)</p> Signup and view all the answers

A storm building sewerage a slope of 1:100 and drainage from 22m x 27m flat roof with intensity of 25mm per 15 min. What is the size of the storm building sewer?

<p>8&quot; (D)</p> Signup and view all the answers

What is required in a manhole that exceeds 1m?

<p>corrosion resistant ladder (B)</p> Signup and view all the answers

The total length of the sanitary building sewer is 100’ and the total fall is 37 ½”. What is the grade of the sewer per foot

<p>3/8&quot; per foot (C)</p> Signup and view all the answers

An 8” storm sewer passed through a manhole, which has an invert elevation of 533.750m it continues to the next manhole which is 85m downstream. What is the invert elevation of the downstream manhole using minimum allowed grade?

<p>634.175m (C)</p> Signup and view all the answers

what is done before the installation of a treatment field?

<p>Determine required clearances soil suitability and size of treatment field then apply for permit (D)</p> Signup and view all the answers

A sanitary manhole is installed inside a building and a noticeable door is present. What is the problem?

<p>vent is extended to atmosphere (D)</p> Signup and view all the answers

A sewage treatment system with a limiting layer of bedrocks 500mm (20”) below grade?

<p>Install a treatment mound, ejector system or a holding tank (A)</p> Signup and view all the answers

What is the purpose of a distribution box in a septic system?

<p>To distribute effluent evenly and allow for inspection of laterals (A)</p> Signup and view all the answers

During annual maintenance. A septic tank has been cleaned and refilled. Excessive sludge is building up is occurs g after restart. What is the cause?

<p>not enough bacteria is added to system (D)</p> Signup and view all the answers

what us the minimum size of item 11?

<p>11/4&quot; (A)</p> Signup and view all the answers

what are the maximum number of fixtures units allowed on a 6" sanitary drain at 1% grade?

<p>700 (C)</p> Signup and view all the answers

What is the maximum number of fixture units allowed on a 4” building drain at 2% grade?

<p>240 (B)</p> Signup and view all the answers

what is the minimum diameter of a unvented floor drain ?

<p>3 (C)</p> Signup and view all the answers

what is the minimum size of item 2?

<p>2&quot; (B)</p> Signup and view all the answers

What is the minimum grade of a 8” building drain with maximum load of 1550 FU?

<p>1:100 (B)</p> Signup and view all the answers

What is the minimum grade of a 8” building drain with the maximum load of 1700FU?

<p>1:50 (A)</p> Signup and view all the answers

what is the component at location 1?

<p>check valve (A)</p> Signup and view all the answers

The elevation of the bottom of a trench for a 3” sanitary building drain is 2760 ft at point A. The pipe is to be laid at minimum slope down to point B at 89ft away. What is the elevation of the trench at point b?

<p>763' (A)</p> Signup and view all the answers

What is the maximum distance between hangers serving ABS?

<p>1.2m (B)</p> Signup and view all the answers

What is the maximum developed length for 3” trap arm for a floor drain?

<p>3.6m (B)</p> Signup and view all the answers

How many roof drains are required for 56m x 70m roof?

<p>6 (C)</p> Signup and view all the answers

What is used to complete a smoke test?

<p>smoke generator (D)</p> Signup and view all the answers

An underground DWV system is ready to be tested. WhAt is the next ste

<p>Schedule inspection with authority having jurisdiction (B)</p> Signup and view all the answers

What is the gauge pressure at the bottom of a 4” pipe that is 25ft high and filled with water?

<p>11psi (B)</p> Signup and view all the answers

What is the size of a clean out on 1 ½” waste pipe?

<p>Same size as pipe served (A)</p> Signup and view all the answers

A washroom with battery of 8exsisting lavatories has the drains and vents running from left to right which will become 10 lavs through renovation. If the Developed length remains 9m at what point will the vent size changed?

<p>The size remains the same (A)</p> Signup and view all the answers

After cleaning the kitchen drain on the second floor of the house what is done to verify the clearance of the wet vented waste stack?

<p>Fill the cleared kitchen sink and release water (B)</p> Signup and view all the answers

How is water line ran under a footing?

<p>So that the footing doesn’t not bear on the pipe (D)</p> Signup and view all the answers

What is done when softened water tastes salty after regeneration?

<p>Lengthen rinse cycle (C)</p> Signup and view all the answers

What is the min size of water supply pipe to a service sink?

<p>1/2 (B)</p> Signup and view all the answers

Where is the water supply line located?

<p>140mm (5 ½”) from the center of the drain 235mm (9 ¼) above floor (C)</p> Signup and view all the answers

What ensure even distribution throughout a domestic hot water distribution system?

<p>balancing valves (D)</p> Signup and view all the answers

what does pipe V represent?

<p>tempered water line (D)</p> Signup and view all the answers

What is installed on water piping of a house having a check valve installed on the water service after the meter.

<p>Thermal expansion tank (B)</p> Signup and view all the answers

What must be installed to prevent back flow into a potable water system cause by back pressure of a toxic substance?

<p>Reduced pressure backflow preventer (D)</p> Signup and view all the answers

What device incorporates 2 single check valves with a relief port located between the check valve?

<p>Dual check with atmospheric port (C)</p> Signup and view all the answers

What is the min height of air gap for ½” water supply line?

<p>25mm and at least 2 times the diameter of the pipe opening (A)</p> Signup and view all the answers

Where is the pump located on a residential domestic hot water recirculating system?

<p>Upstream of the temperature mixing valve (A)</p> Signup and view all the answers

When calculations pump size for a water distribution system, what factors might be considered?

<p>Length or run working pressure and gpm (A)</p> Signup and view all the answers

What is installed for the removal of a submersible pump in a area where frost is a factor?

<p>pitless adaptors (C)</p> Signup and view all the answers

What device controls normal operation of a pump in a deep well and where is it installed?

<p>Pressure switch installed on the pressure tank (C)</p> Signup and view all the answers

What does adjusting screw #1 on a pressure switch change?

<p>The cut in and cut out pressure (D)</p> Signup and view all the answers

When a faucet is turned on, the pressure pump is short-cycling. What is the cause?

<p>The bladder is ruptured (A)</p> Signup and view all the answers

In order to maintain flood level rim at 785mm (31”) for fixture 2. What is height from finished floor to center of the carrier arm

<p>745mm 29 ¼ (C)</p> Signup and view all the answers

What is the height from finished floor for the hole for anchor screws in the hospital installation?

<p>740mm 29 ⅛” (B)</p> Signup and view all the answers

What is the C-C distance between the carriers if demision X equals 3200mm (10’ 6”)

<p>400mm 15 ¾” (A)</p> Signup and view all the answers

What is the minimum air break in a 2” drain pipe off a indirectly connected appliance?

<p>2&quot; (B)</p> Signup and view all the answers

What must be ensure when installing a shower receptor?

<p>Shower is built to be leak free through the wall and floors (C)</p> Signup and view all the answers

Which fixture can be connected directly or indirectly connected to a sanitary drainage system?

<p>drinking fountain (A)</p> Signup and view all the answers

Water closet tank is filling every 10 - 15mins. What is the cause?

<p>Flapper valve is leaking (C)</p> Signup and view all the answers

Where is the cartridge type filter installed in a water system?

<p>At the point of use (A)</p> Signup and view all the answers

What causes water to be hard?

<p>C. Magnesium and calcium (C)</p> Signup and view all the answers

After a pH test has been performed and the pH is to low, other than a neutralizer what else is added?

<p>Sofa and ash feeder (D)</p> Signup and view all the answers

What is the maximum number of 1” branches that can be taken off a 4” main?

<p>16 (C)</p> Signup and view all the answers

What is the amount of linear expansion on a copper pipe that is 45m in length and a change in temp from 15degrees to 93 degrees

<p>59.25mm (D)</p> Signup and view all the answers

Where is in-line circulator pump placed in a hydronic heating system?

<p>Upstream of the diaphragm expansion tank (B)</p> Signup and view all the answers

When installing a radiant panel heating system. What is done to balance?

<p>Install balancing valve on each loop of the header connection (C)</p> Signup and view all the answers

When performing a test on a hydronic heating system. How much 100% glycol must be added to the system?

<p>112L 24.6gal (C)</p> Signup and view all the answers

What is the lowest temperature water returning to a atmospheric cast iron?

<p>B. 53 138 F (B)</p> Signup and view all the answers

How many BTU are required to raise the temp of 30 imp gal of water from 60?

<p>36000 (D)</p> Signup and view all the answers

The concentration of gycol required is 25%. How much glycol must be added to the system?

<p>25.8L 5.7gal (B)</p> Signup and view all the answers

Which component is installed to control water flow in a radiant in floor hydronic heating system?

<p>Balancing valve (D)</p> Signup and view all the answers

When a low water cut off is installed too low on a hydronic boiler system, what will be the result?

<p>Heat exchanger will burn out (C)</p> Signup and view all the answers

How is a copper heating tube installed through a metal cabinet end cap?

<p>Protected by a proper spacer of insulation device to prevent wear (D)</p> Signup and view all the answers

What is done to check for heat transfer in a in floor heating system?

<p>Check the differential temperature between gauges (D)</p> Signup and view all the answers

The concrete is overheating on a in floor heating system in a parking garage. What is the problem?

<p>Slab sensor has malfunctioned (A)</p> Signup and view all the answers

When connecting a domestic cold water to a drain pipe heat recovery coil. What characteristics achieve maximum heat exchange?

<p>Parallel flow (A)</p> Signup and view all the answers

When installing a natural gas fired unit heater. Where is the drip leg installed ?

<p>Upstream of the appliance regulator and downstream of the union (D)</p> Signup and view all the answers

What is the procedure for installing randon migration components?

<p>Installed in-line fan, manometer than gooseneck (A)</p> Signup and view all the answers

An alteration has been complete on a gas main. What is the testing procedure?

<p>Isolate all componets then test at required pressure (C)</p> Signup and view all the answers

What is the procedure to service an air line termination unit and compressed air line unit?

<p>Replace filter verify regulator operations then add air tool oil to lubricate (B)</p> Signup and view all the answers

What pipe uses fabricated extrusions when it is being manufactured?

<p>fibreglass pipe (B)</p> Signup and view all the answers

What component is used to protect piping when fitted to equipment that causes excessive vibration ?

<p>flexible connections (D)</p> Signup and view all the answers

What specific information is used to determine when a specific piece of machine is being used?

<p>manufacturer documentation (B)</p> Signup and view all the answers

Flashcards

Key elements of WHMIS

Worker education, labeling requirements, and Safety Data Sheets (SDS).

Extinguisher for Wood Fire

Class A extinguishers are used for extinguishing wood fires.

Achieving Zero Energy State

Lock all electrical energy drain pressure, then lockout drain open on tank to achieve zero energy status when locking out the system.

Defective Power Tool Handling

It must be removed from service until repaired by an authorized person.

Signup and view all the flashcards

Unclear instructions

Should clarify the instruction with the supervisor.

Signup and view all the flashcards

Hub and Spigot Gasket Joint Assembly

Cut end of pipe square, bevel end of pipe, clean pipe end and fittings, mark pipe for insertion depth, lubricate gasket and spigot, then push spigot into pipe until depth reached

Signup and view all the flashcards

Change in Direction with Cast Iron ⅛ Bend

45 degrees

Signup and view all the flashcards

Procedure to Cut Glass

Measure, mark, score, heat, then tap.

Signup and view all the flashcards

Purpose of Distribution Box in Septic System

To distribute effluent evenly and allow for inspection of laterals

Signup and view all the flashcards

Minimum size of item 11

1 1/4"

Signup and view all the flashcards

Maximum FU on 6" Sanitary Drain at 1% Grade

700

Signup and view all the flashcards

Maximum Fixture Units on 4” Building Drain at 2% Grade

240

Signup and view all the flashcards

Minimum Diameter of Unvented Floor Drain

3

Signup and view all the flashcards

Minimum size of item 2

2"

Signup and view all the flashcards

Minimum grade of a 8” building drain with maximum load of 1550 FU?

1:100

Signup and view all the flashcards

Component at Location 1

Check valve

Signup and view all the flashcards

Maximum distance between hangers serving ABS

1.2m

Signup and view all the flashcards

More Like This

Sample Quiz
20 questions

Sample Quiz

EffectiveTopology2534 avatar
EffectiveTopology2534
Sample Quiz
20 questions

Sample Quiz

EffectiveTopology2534 avatar
EffectiveTopology2534
Sample Quiz
47 questions

Sample Quiz

UndisputableCommonsense6303 avatar
UndisputableCommonsense6303
Sample Quiz
20 questions

Sample Quiz

UnquestionableNovaculite2668 avatar
UnquestionableNovaculite2668
Use Quizgecko on...
Browser
Browser