Podcast
Questions and Answers
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (general) that a Third Class Power Engineer may operate as Chief Power Engineer?
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (general) that a Third Class Power Engineer may operate as Chief Power Engineer?
- Up to 5000 kW (correct)
- Up to 1000 kW
- Up to 15,000 kW
- Up to 10,000 kW
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (oilfield once-through boiler) that a Third Class Power Engineer may operate as Chief Power Engineer?
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (oilfield once-through boiler) that a Third Class Power Engineer may operate as Chief Power Engineer?
- Up to 1000 kW
- Up to 5000 kW
- Up to 10,000 kW (correct)
- Up to 15,000 kW
According to the Power Engineers Regulation AR 85-2018, what is a historic boiler?
According to the Power Engineers Regulation AR 85-2018, what is a historic boiler?
- A boiler that is no longer in use
- A boiler that is part of a power plant of historic interest (correct)
- A boiler used in historic buildings
- A boiler that has been in operation for more than 50 years
According to the Power Engineers Regulation AR 85-2018, what is the range of boiler capacity in kilowatts that a Third Class Power Engineer can operate as shift engineer?
According to the Power Engineers Regulation AR 85-2018, what is the range of boiler capacity in kilowatts that a Third Class Power Engineer can operate as shift engineer?
According to the Pressure Welders Regulation AR 169-2014, what is the name of the card that is part of a certificate of competency and is issued to a pressure welder who succeeds at a performance qualification test?
According to the Pressure Welders Regulation AR 169-2014, what is the name of the card that is part of a certificate of competency and is issued to a pressure welder who succeeds at a performance qualification test?
According to the Power Engineers Regulation AR 85-2018, what section describes the steps that the administrator must follow once the pressure equipment design has been registered?
According to the Power Engineers Regulation AR 85-2018, what section describes the steps that the administrator must follow once the pressure equipment design has been registered?
According to the Power Engineers Regulation AR 85-2018, what must the owner do in case of unsafe conditions, accident, or fire related to pressure equipment?
According to the Power Engineers Regulation AR 85-2018, what must the owner do in case of unsafe conditions, accident, or fire related to pressure equipment?
According to the Power Engineers Regulation AR 85-2018, which codes and standards are listed in AR / 49, Section 6?
According to the Power Engineers Regulation AR 85-2018, which codes and standards are listed in AR / 49, Section 6?
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (general) that a Third Class Power Engineer may operate as Chief Power Engineer?
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (general) that a Third Class Power Engineer may operate as Chief Power Engineer?
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (oilfield once-through boiler) that a Third Class Power Engineer may operate as Chief Power Engineer?
According to the Power Engineers Regulation AR 85-2018, what is the maximum rating for a power plant (oilfield once-through boiler) that a Third Class Power Engineer may operate as Chief Power Engineer?
Flashcards are hidden until you start studying
Study Notes
Power Engineers Regulation AR 85-2018
- A Third Class Power Engineer may operate as Chief Power Engineer for a power plant (general) with a maximum rating of 10 MW.
- A Third Class Power Engineer may operate as Chief Power Engineer for a power plant (oilfield once-through boiler) with a maximum rating of 5 MW.
Boiler Capacity
- A Third Class Power Engineer can operate as a shift engineer for boilers with a capacity range of 10 kW to 500 kW.
Historic Boiler
- A historic boiler is defined as a boiler that was in operation before June 30, 1957.
Pressure Welders Regulation AR 169-2014
- A pressure welder who succeeds at a performance qualification test is issued a "Performance Qualification Card" as part of their certificate of competency.
Pressure Equipment Design
- Section 10 of the Power Engineers Regulation AR 85-2018 describes the steps that the administrator must follow once the pressure equipment design has been registered.
Safety Requirements
- In case of unsafe conditions, accident, or fire related to pressure equipment, the owner must inform the Administrator and take immediate corrective action.
Codes and Standards
- Section 6 of the Power Engineers Regulation AR 85-2018 lists the following codes and standards: ASME, ASME B31, and API.
Studying That Suits You