What is the function and description of T-100?

Distillation Tower separates based on BP has 8 bubble trays

What is the function of E-102?

Preheater (cooling interchanger) heat glycol before going to T-100

What is E-101?

Reboiler (double pass heat exchanger)

What is the function of E-100?

<p>Condenser (condenses OVH vapor into liquid)</p> Signup and view all the answers

What is the function of D-100?

<p>Reflux Drum (collects condensed vapors from top of column, controls amount of reflux recycled back into column improving separation)</p> Signup and view all the answers

What is D-101?

<p>Seal Liquid Drum</p> Signup and view all the answers

What is E-103?

<p>Seal Liquid Cooler</p> Signup and view all the answers

What are P-100A/B?

<p>Pumps for Tower Bottoms</p> Signup and view all the answers

What are P-101A/B?

<p>Reflux Pumps</p> Signup and view all the answers

What is C-100?

<p>Compressor</p> Signup and view all the answers

What are P-102A/B?

<p>Seal Liquid Pumps</p> Signup and view all the answers

Describe the path of the "OVHD to Condenser" line.

<p>3rd floor/ 1st floor to E-100</p> Signup and view all the answers

Describe the "Condenser to Reflux Drum" line.

<p>Drain line to reflux drum</p> Signup and view all the answers

Where is the Condenser CWS (Cooling Water Supply) located?

<p>East of E-100 level one</p> Signup and view all the answers

Where is the Condenser CWR (Cooling Water Return) located?

<p>West of E-100 level one</p> Signup and view all the answers

Where does the "Reflux to Top of Column" line originate?

<p>Reflux pumps discharge Ground floor north side</p> Signup and view all the answers

Where does the "Reflux to Tank Farm" line originate?

<p>Reflux pumps discharge North East ground floor</p> Signup and view all the answers

Describe the path of the "Bottoms to Interchanger" line.

<p>From bottoms pump P100 to E-102 Cooler/Preheater 1st floor</p> Signup and view all the answers

Where does the "Interchanger to Tank Farm" line run?

<p>Bottoms P-100 to E-102 1st floor</p> Signup and view all the answers

Describe the "Bottoms to Reboiler" line.

<p>P100 to E-101 1st floor</p> Signup and view all the answers

Describe the "Reboiler to Column" line.

<p>1st floor pipe</p> Signup and view all the answers

Describe the "Feed to Interchanger" line.

<p>Tk 202 A to E-102 Cooler/heater 1st floor</p> Signup and view all the answers

Describe the "Interchanger to Sump & #6" line location.

<p>1st floor</p> Signup and view all the answers

Where is the "Steam to Reboiler" line located?

<p>1st floor E-102 (east pipe)</p> Signup and view all the answers

Describe the "D-101 OVHD to TK-200A/B" line.

<p>Vents to 200B Pipe North East</p> Signup and view all the answers

Describe the "P-100A/B to D-101" line based on the definition.

<p>Tank 100 to Seal liquid ground</p> Signup and view all the answers

Where is the "Seal Liquid to Vacuum Pump" line located?

<p>ground west of E-103</p> Signup and view all the answers

What is PSV-153, its location, and set pressure?

<p>Feed Tk 202 to Cooler/Preheater (E-102) 50 lbs pressure (east pipe)</p> Signup and view all the answers

What is FIT-111 and where is it located?

<p>Downstream E-102 (Cooler/Preheater) to tray 6</p> Signup and view all the answers

What is FV-111 and where is it located?

<p>Downstream E-102 (Cooler/Preheater) to tray 6</p> Signup and view all the answers

What are PI-100 A/B and where are they located?

<p>bottoms pumps ground east of unit</p> Signup and view all the answers

What is FIT-126 and where is it located?

<p>bottoms to cooler E-102 (west of t-100 base)</p> Signup and view all the answers

What is FV-126 and where is it located?

<p>bottoms to cooler E-102 (west of t-100 base)</p> Signup and view all the answers

What is PSV-154, its location, and set pressure?

<p>Cooler E-102 to Tank T-100 100 psig (west pipe)</p> Signup and view all the answers

What is TIT-129 and where is it located?

<p>Feed 202 to cooler 102 1st floor (upstream)</p> Signup and view all the answers

What is PSV-107 and its location?

<p>Feed Tk202 to Cooler 102 3rd floor</p> Signup and view all the answers

What is PIT-108 and where is it located?

<p>OVH tower 3rd floor</p> Signup and view all the answers

What is PV-108A and its function/location?

<p>From atm to Reflux Drum 1st floor</p> Signup and view all the answers

What is PV-108B and its function/location?

<p>Reflux drum to atm 1st floor</p> Signup and view all the answers

What is TIT-109 and where is it located?

<p>OVH tower 3rd floor</p> Signup and view all the answers

What is HV-127 and its function/location?

<p>From E-101 to sump tower-100 2nd floor</p> Signup and view all the answers

What is FIT-110 and where is it located?

<p>P-101 A/B to top Reflux to tower 2nd floor</p> Signup and view all the answers

What is FV-110 and where is it located?

<p>P-101 A/B to top Reflux to tower 2nd floor</p> Signup and view all the answers

What is DPIT-113 and what does it measure?

<p>Pressure diff from tray 1 to 8 2nd floor</p> Signup and view all the answers

What is TIT-123 and what does it measure?

<p>8th tray temp 3rd floor</p> Signup and view all the answers

What is TIT-124 and what does it measure?

<p>sump tower temp 2nd floor</p> Signup and view all the answers

What is LG-114 and where is it located?

<p>level gauge for Bottoms 1st floor</p> Signup and view all the answers

What is LIT-115 and where is it located?

<p>level indicator for Bottoms t-100 1st floor</p> Signup and view all the answers

What is LG-134 and where is it located?

<p>Reflux Drum level gauge ground floor</p> Signup and view all the answers

What is LIT-135 and where is it located?

<p>Reflux Drum Level Transmitter ground floor</p> Signup and view all the answers

What is TIT-136 and what does it measure?

<p>Reflux Drum Temp ground floor</p> Signup and view all the answers

What are PI-101A/B and where are they located?

<p>Reflux pumps ground north of t-100</p> Signup and view all the answers

What is AIT-138 and where is it located?

<p>Reflux to tank line North ground analyzer</p> Signup and view all the answers

What is FIT-139 and where is it located?

<p>Reflux to tank line North ground of t-100 discharge line</p> Signup and view all the answers

What is LV-140 and where is it located?

<p>Reflux to tank line North ground of t-100 discharge</p> Signup and view all the answers

What is PI-132 and where is it located?

<p>Reflux drum temp gauge ground floor</p> Signup and view all the answers

What is LG-142 and what are its typical operating levels?

<p>Seal Liquid level gauge low 20% high 80%</p> Signup and view all the answers

What is described for tag LALL-143 and its set point?

<p>Seal liquid high alarm 80%</p> Signup and view all the answers

What is described for tag LAHH-141 and its set point?

<p>Seal liquid low alarm 20%</p> Signup and view all the answers

What is PI-147 and where is it located?

<p>Reflux to C-100 upstream of compressor</p> Signup and view all the answers

What are PI-102A/B and where are they located?

<p>Seal liquid pumps north side of E-103</p> Signup and view all the answers

What is TIT-146 and where is it located?

<p>Seal liquid Cooler E103 (downstream) to C-100</p> Signup and view all the answers

What is FIT-145 and where is it located?

<p>Seal liquid Cooler E103 (downstream) to C-100</p> Signup and view all the answers

What is FV-145 and where is it located?

<p>Seal liquid Cooler E103 (downstream) to C-100</p> Signup and view all the answers

What is the function of T-100 in the distillation system?

<p>Distillation Tower, separates components based on boiling point (BP) and has 8 bubble trays.</p> Signup and view all the answers

What is the function of E-102?

<p>Preheater (cooling interchanger) that heats glycol before it enters T-100.</p> Signup and view all the answers

What type of equipment is E-101?

<p>Reboiler (double pass heat exchanger).</p> Signup and view all the answers

What is the function of E-100?

<p>Condenser (condenses overhead (OVH) vapor into liquid).</p> Signup and view all the answers

What is D-100 and its purpose?

<p>Reflux Drum. It collects condensed vapors from the top of the column and controls the amount of reflux recycled back into the column, improving separation.</p> Signup and view all the answers

What is D-101?

<p>Seal Liquid Drum.</p> Signup and view all the answers

What is the function of E-103?

<p>Seal Liquid Cooler.</p> Signup and view all the answers

What equipment do P-100A/B represent?

<p>Pumps for Tower Bottoms.</p> Signup and view all the answers

What equipment do P-101A/B represent?

<p>Reflux Pumps.</p> Signup and view all the answers

What type of equipment is C-100?

<p>Compressor.</p> Signup and view all the answers

What equipment do P-102A/B represent?

<p>Seal Liquid Pumps.</p> Signup and view all the answers

Where does the OVHD to Condenser line run?

<p>From the 3rd floor (likely top of T-100) to the 1st floor (location of E-100).</p> Signup and view all the answers

What is the purpose of the Condenser to Reflux Drum line?

<p>It is a drain line carrying condensed liquid from the condenser (E-100) to the reflux drum (D-100).</p> Signup and view all the answers

Where is the Condenser Cooling Water Supply (CWS) connection located?

<p>East of E-100 on level one.</p> Signup and view all the answers

Where is the Condenser Cooling Water Return (CWR) connection located?

<p>West of E-100 on level one.</p> Signup and view all the answers

Where does the Reflux to Top of Column line originate?

<p>From the Reflux pumps (P-101A/B) discharge, located on the ground floor, North side.</p> Signup and view all the answers

Where does the Reflux to Tank Farm line originate?

<p>From the Reflux pumps (P-101A/B) discharge, located on the North East corner of the ground floor.</p> Signup and view all the answers

Describe the path of the Bottoms to Interchanger line.

<p>From the bottoms pumps (P-100A/B) to the Cooler/Preheater (E-102) on the 1st floor.</p> Signup and view all the answers

Describe the path of the Interchanger to Tank Farm line.

<p>From the Cooler/Preheater (E-102) on the 1st floor, originating from the Bottoms Pumps (P-100A/B).</p> Signup and view all the answers

Describe the path of the Bottoms to Reboiler line.

<p>From the bottoms pumps (P-100A/B) to the Reboiler (E-101) on the 1st floor.</p> Signup and view all the answers

Where is the Reboiler to Column pipe located?

<p>On the 1st floor, connecting the Reboiler (E-101) back to the Distillation Tower (T-100).</p> Signup and view all the answers

Describe the path of the Feed to Interchanger line.

<p>From Tank Tk 202 A to the Cooler/heater (E-102) on the 1st floor.</p> Signup and view all the answers

Where is the Interchanger to Sump & #6 located?

<p>On the 1st floor.</p> Signup and view all the answers

Where is the Steam to Reboiler pipe located?

<p>On the 1st floor, it is the east pipe connected to E-101 (Reboiler). Note: Definition incorrectly mentions E-102.</p> Signup and view all the answers

Where does the D-101 OVHD line vent to?

<p>It vents to TK-200A/B via a pipe located on the North East side.</p> Signup and view all the answers

Describe the path of the P-100A/B to D-101 line.

<p>From the Tower Bottoms Pumps (P-100A/B, near Tank 100) to the Seal Liquid Drum (D-101) on the ground floor.</p> Signup and view all the answers

Where is the Seal Liquid to Vacuum Pump line located?

<p>On the ground floor, west of the Seal Liquid Cooler (E-103).</p> Signup and view all the answers

Identify PSV-153, its location, protected line, and set pressure.

<p>Pressure Safety Valve located on the feed line from Tk 202 to the Cooler/Preheater (E-102). Set pressure is 50 lbs (psig). It is the east pipe.</p> Signup and view all the answers

What is FIT-111 and where is it located?

<p>Flow Indicator Transmitter, located downstream of the Cooler/Preheater (E-102) on the line going to tray 6 of T-100.</p> Signup and view all the answers

What is FV-111 and where is it located?

<p>Flow Control Valve, located downstream of the Cooler/Preheater (E-102) on the line going to tray 6 of T-100.</p> Signup and view all the answers

What are PI-100 A/B and where are they located?

<p>Pressure Indicators, located on the discharge of the bottoms pumps (P-100A/B) on the ground floor, east of the unit.</p> Signup and view all the answers

What is FIT-126 and where is it located?

<p>Flow Indicator Transmitter, located on the bottoms line going to the cooler (E-102), west of the base of T-100.</p> Signup and view all the answers

What is FV-126 and where is it located?

<p>Flow Control Valve, located on the bottoms line going to the cooler (E-102), west of the base of T-100.</p> Signup and view all the answers

Identify PSV-154, its location, protected line, and set pressure.

<p>Pressure Safety Valve located on the line from Cooler (E-102) to Tank (likely storage tanks, not T-100). Set pressure is 100 psig. It is the west pipe.</p> Signup and view all the answers

What is TIT-129 and where is it located?

<p>Temperature Indicator Transmitter, located on the feed line from Tk 202 to cooler E-102 (upstream of E-102) on the 1st floor.</p> Signup and view all the answers

Identify PSV-107 and its location.

<p>Pressure Safety Valve located on the line from Feed Tk 202 to Cooler 102 (E-102), likely located on the 3rd floor.</p> Signup and view all the answers

What is PIT-108 and where is it located?

<p>Pressure Indicator Transmitter, located on the overhead (OVH) line of the tower (T-100) on the 3rd floor.</p> Signup and view all the answers

What is PV-108A and where is it located?

<p>Pressure Control Valve, located on a line from the atmosphere (atm) to the Reflux Drum (D-100) on the 1st floor.</p> Signup and view all the answers

What is PV-108B and where is it located?

<p>Pressure Control Valve, located on a line from the Reflux Drum (D-100) to the atmosphere (atm) on the 1st floor.</p> Signup and view all the answers

What is TIT-109 and where is it located?

<p>Temperature Indicator Transmitter, located on the overhead (OVH) line of the tower (T-100) on the 3rd floor.</p> Signup and view all the answers

What is HV-127 and where is it located?

<p>Hand Valve (Manual Valve), located on a line from the Reboiler (E-101) to the sump of Tower T-100 on the 2nd floor.</p> Signup and view all the answers

What is FIT-110 and where is it located?

<p>Flow Indicator Transmitter, located on the reflux line from pumps P-101 A/B to the top of the tower, on the 2nd floor.</p> Signup and view all the answers

What is FV-110 and where is it located?

<p>Flow Control Valve, located on the reflux line from pumps P-101 A/B to the top of the tower, on the 2nd floor.</p> Signup and view all the answers

What is DPIT-113 and where is it located?

<p>Differential Pressure Indicator Transmitter, measuring the pressure difference between tray 1 and tray 8 of T-100, located on the 2nd floor.</p> Signup and view all the answers

What is TIT-123 and where is it located?

<p>Temperature Indicator Transmitter, measuring the temperature on the 8th tray of T-100, located on the 3rd floor.</p> Signup and view all the answers

What is TIT-124 and where is it located?

<p>Temperature Indicator Transmitter, measuring the temperature in the tower sump (bottom of T-100), located on the 2nd floor.</p> Signup and view all the answers

What is LG-114 and where is it located?

<p>Level Gauge, for the Bottoms section of T-100, located on the 1st floor.</p> Signup and view all the answers

What is LIT-115 and where is it located?

<p>Level Indicator Transmitter, for the Bottoms section of T-100, located on the 1st floor.</p> Signup and view all the answers

What is LG-134 and where is it located?

<p>Level Gauge, for the Reflux Drum (D-100), located on the ground floor.</p> Signup and view all the answers

What is LIT-135 and where is it located?

<p>Level Indicator Transmitter, for the Reflux Drum (D-100), located on the ground floor.</p> Signup and view all the answers

What is TIT-136 and where is it located?

<p>Temperature Indicator Transmitter, for the Reflux Drum (D-100), located on the ground floor.</p> Signup and view all the answers

What are PI-101A/B and where are they located?

<p>Pressure Indicators, located on the discharge of the reflux pumps (P-101A/B) on the ground floor, north of T-100.</p> Signup and view all the answers

What is AIT-138 and where is it located?

<p>Analyzer Indicator Transmitter, located on the reflux-to-tank line (product line) on the North side of the ground floor.</p> Signup and view all the answers

What is FIT-139 and where is it located?

<p>Flow Indicator Transmitter, located on the reflux-to-tank line (product discharge line) on the North side of the ground floor near T-100.</p> Signup and view all the answers

What is LV-140 and where is it located?

<p>Level Control Valve, located on the reflux-to-tank line discharge on the North side of the ground floor near T-100.</p> Signup and view all the answers

What is PI-132 and where is it located?

<p>Pressure Indicator (Gauge), for the Reflux Drum (D-100), located on the ground floor.</p> Signup and view all the answers

What is LG-142 and what are its operational levels?

<p>Level Gauge for the Seal Liquid Drum (D-101). Low level is 20%, high level is 80%.</p> Signup and view all the answers

What is LALL-143 and its function?

<p>Level Alarm Low Low (interpreted as Level Alarm High based on definition), provides a high alarm for the seal liquid level at 80%.</p> Signup and view all the answers

What is LAHH-141 and its function?

<p>Level Alarm High High (interpreted as Level Alarm Low based on definition), provides a low alarm for the seal liquid level at 20%.</p> Signup and view all the answers

What is PI-147 and where is it located?

<p>Pressure Indicator, located on the line from the Reflux Drum (D-100) to the Compressor (C-100), upstream of the compressor.</p> Signup and view all the answers

What are PI-102A/B and where are they located?

<p>Pressure Indicators, located on the discharge of the seal liquid pumps (P-102A/B) on the north side of the Seal Liquid Cooler (E-103).</p> Signup and view all the answers

What is TIT-146 and where is it located?

<p>Temperature Indicator Transmitter, located on the seal liquid line downstream of the cooler (E-103) going to the compressor (C-100).</p> Signup and view all the answers

What is FIT-145 and where is it located?

<p>Flow Indicator Transmitter, located on the seal liquid line downstream of the cooler (E-103) going to the compressor (C-100).</p> Signup and view all the answers

What is FV-145 and where is it located?

<p>Flow Control Valve, located on the seal liquid line downstream of the cooler (E-103) going to the compressor (C-100).</p> Signup and view all the answers

Flashcards

T-100

Distillation Tower separates based on BP has 8 bubble trays.

E-102

Preheater (cooling interchanger) heat glycol before going to T-100.

E-101

Reboiler (double pass heat exchanger).

E-100

Condenser (condenses OVH vapor into liquid).

Signup and view all the flashcards

D-100

Reflux Drum collects condensed vapors from top of column, controls amount of reflux recycled back into column improving separation.

Signup and view all the flashcards

D-101

Seal Liquid Drum

Signup and view all the flashcards

E-103

Seal Liquid Cooler

Signup and view all the flashcards

P-100A/B

Pumps for Tower Bottoms

Signup and view all the flashcards

P-101A/B

Reflux Pumps

Signup and view all the flashcards

C-100

Compressor

Signup and view all the flashcards

P-102A/B

Seal Liquid Pumps

Signup and view all the flashcards

OVHD to Condenser

3rd floor/ 1st floor to E-100

Signup and view all the flashcards

Condenser to Reflux Drum

Drain line to reflux drum

Signup and view all the flashcards

Condenser CWS

East of E-100 level one

Signup and view all the flashcards

Condenser CWR

West of E-100 level one

Signup and view all the flashcards

Reflux to Top of Column

Reflux pumps discharge Ground floor north side

Signup and view all the flashcards

Reflux to Tank Farm

Reflux pumps discharge North East ground floor

Signup and view all the flashcards

Bottoms to Interchanger

From bottoms pumpP100 to E-102 Cooler/Preheater 1st floor

Signup and view all the flashcards

Interchanger to Tank Farm

Bottoms P-100 to E-102 1st floor

Signup and view all the flashcards

Bottoms to Reboiler

P100 to E-101 1st floor

Signup and view all the flashcards

Reboiler to Column

1st floor pipe

Signup and view all the flashcards

Feed to Interchanger

Tk 202 A to E-102 Cooler/heater 1st floor

Signup and view all the flashcards

Interchanger to Sump & #6

1st floor

Signup and view all the flashcards

Steam to Reboiler

1st floor E-102 (east pipe)

Signup and view all the flashcards

D-101 OVHD to TK-200A/B

Vents to 200B Pipe North East

Signup and view all the flashcards

P-100A/B to D-101

Tank 100 to Seal liquid ground

Signup and view all the flashcards

Seal Liquid to Vacuum Pump

ground west of E-103

Signup and view all the flashcards

PSV-153 & Set Pressure

Feed Tk 202 to Cooler/Preheater (E-102) 50 lbs pressure (east pipe)

Signup and view all the flashcards

FIT-111

Downstream E-102 (Cooler/Preheater) to tray 6

Signup and view all the flashcards

FV-111

Downstream E-102 (Cooler/Preheater) to tray 6

Signup and view all the flashcards

PI-100 A/B

bottoms pumps ground east of unit

Signup and view all the flashcards

FIT-126

bottoms to cooler E-102 (west of t-100 base)

Signup and view all the flashcards

FV-126

bottoms to cooler E-102 (west of t-100 base)

Signup and view all the flashcards

PSV-154 & Set Pressure

Cooler E-102 to Tank T-100 100 psig (west pipe)

Signup and view all the flashcards

TIT-129

Feed 202 to cooler 102 1st floor (upstream)

Signup and view all the flashcards

PSV-107 & Set Pressure

Feed Tk202 to Cooler 102 3rd floor

Signup and view all the flashcards

PIT-108

OVH tower 3rd floor

Signup and view all the flashcards

PV-108A

From atm to Reflux Drum 1st floor

Signup and view all the flashcards

PV-108B

Reflux drum to atm 1st floor

Signup and view all the flashcards

TIT-109

OVH tower 3rd floor

Signup and view all the flashcards

HV-127

From E-101 to sump tower-100 2nd floor

Signup and view all the flashcards

FIT-110

P-101 A/B to top Reflux to tower 2nd floor

Signup and view all the flashcards

FV-110

P-101 A/B to top Reflux to tower 2nd floor

Signup and view all the flashcards

DPIT-113

Pressure diff from tray 1 to 8 2nd floor

Signup and view all the flashcards

TIT-123

8th tray temp 3rd floor

Signup and view all the flashcards

TIT-124

sump tower temp 2nd floor

Signup and view all the flashcards

LG-114

level gauge for Bottoms 1st floor

Signup and view all the flashcards

LIT-115

level indicator for Bottoms t-100 1st floor

Signup and view all the flashcards

LG-134

Reflux Drum level gauge ground floor

Signup and view all the flashcards

LIT-135

Reflux Drum Level Transmitter ground floor

Signup and view all the flashcards

TIT-136

Reflux Drum Temp ground floor

Signup and view all the flashcards

PI-101A/B

Reflux pumps ground north of t-100

Signup and view all the flashcards

AIT-138

Reflux to tank line North ground analyzer

Signup and view all the flashcards

FIT-139

Reflux to tank line North ground of t-100 discharge line

Signup and view all the flashcards

LV-140

Reflux to tank line North ground of t-100 discharge

Signup and view all the flashcards

PI-132

Reflux drum temp gauge ground floor

Signup and view all the flashcards

LG-142

Seal Liquid level gauge low 20% high 80%

Signup and view all the flashcards

LALL-143

Seal liquid high alarm 80%

Signup and view all the flashcards

LAHH-141

Seal liquid low alarm 20%

Signup and view all the flashcards

PI-147

Reflux to C-100 upstream of compressor

Signup and view all the flashcards

PI-102A/B

Seal liquid pumps north side of E-103

Signup and view all the flashcards

TIT-146

Seal liquid Cooler E103 (downstream) to C-100

Signup and view all the flashcards

FIT-145

Seal liquid Cooler E103 (downstream) to C-100

Signup and view all the flashcards

FV-145

Seal liquid Cooler E103 (downstream) to C-100

Signup and view all the flashcards

Study Notes

Distillation Tower (T-100)

  • Distillation Tower (T-100) separates components based on boiling points (BP).
  • The tower contains 8 bubble trays.

Preheater (E-102)

  • E-102 is a preheater, also known as a cooling interchanger.
  • It heats glycol before it enters the T-100 distillation tower.

Reboiler (E-101)

  • E-101 is a reboiler, specifically a double pass heat exchanger.

Condenser (E-100)

  • E-100 is a condenser that converts overhead vapor into liquid.

Reflux Drum (D-100)

  • D-100 is a reflux drum that collects condensed vapors from the top of the distillation column.
  • It controls the amount of reflux recycled back into the column to improve separation.

Seal Liquid Drum (D-101)

  • D-101 is the seal liquid drum.

Seal Liquid Cooler (E-103)

  • E-103 is the seal liquid cooler.

Tower Bottoms Pumps (P-100A/B)

  • P-100A and P-100B are pumps used for tower bottoms.

Reflux Pumps (P-101A/B)

  • P-101A and P-101B are reflux pumps.

Compressor (C-100)

  • C-100 is a compressor.

Seal Liquid Pumps (P-102A/B)

  • P-102A and P-102B are seal liquid pumps.

Location: Overhead to Condenser

  • The overhead line runs from the 3rd floor to the 1st floor, connecting to E-100 (condenser).

Location: Condenser to Reflux Drum

  • A drain line connects the condenser to the reflux drum.

Location: Condenser Cooling Water Supply (CWS)

  • The CWS for the condenser is located east of E-100 on level one.

Location: Condenser Cooling Water Return (CWR)

  • The CWR for the condenser is located west of E-100 on level one.

Location: Reflux to Top of Column

  • The discharge of the reflux pumps to the top of the column is on the ground floor, north side.

Location: Reflux to Tank Farm

  • The discharge of the reflux pumps to the tank farm is on the ground floor, northeast side.

Location: Bottoms to Interchanger

  • The line runs from bottoms pump P-100 to the E-102 cooler/preheater on the 1st floor.

Location: Interchanger to Tank Farm

  • The bottoms line runs from P-100 to E-102 on the 1st floor.

Location: Bottoms to Reboiler

  • The line goes from P-100 to E-101 on the 1st floor.

Location: Reboiler to Column

  • The pipe is located on the 1st floor.

Location: Feed to Interchanger

  • The feed goes from Tank 202 A to E-102 cooler/heater on the 1st floor.

Location: Interchanger to Sump & #6

  • This is located on the 1st floor.

Location: Steam to Reboiler

  • The steam line to E-102 is on the 1st floor (east pipe).

Location: D-101 Overhead to TK-200A/B

  • Vents to 200B Pipe North East

Location: P-100A/B to D-101

  • The line goes from Tank 100 to seal liquid ground.

Location: Seal Liquid to Vacuum Pump

  • Located on the ground west of E-103.

PSV-153

  • This pressure safety valve is located on the feed line from Tank 202 to the Cooler/Preheater (E-102).
  • The set pressure is 50 lbs.
  • It's located on the east pipe.

FIT-111

  • This flow indicating transmitter is located downstream of E-102 (Cooler/Preheater) to tray 6.

FV-111

  • This flow valve is located downstream of E-102 (Cooler/Preheater) to tray 6.

PI-100 A/B

  • These pressure indicators are located at the bottoms pumps on the ground east of the unit.

FIT-126

  • This flow indicating transmitter is located on the bottoms line to the cooler E-102, west of the T-100 base.

FV-126

  • This flow valve is located on the bottoms line to the cooler E-102, west of the T-100 base.

PSV-154

  • This pressure safety valve is located on the Cooler E-102 to Tank T-100 line.
  • The set pressure is 100 psig.
  • It's located on the west pipe.

TIT-129

  • This temperature indicating transmitter is located on the feed line from 202 to cooler 102 on the 1st floor (upstream).

PSV-107

  • This pressure safety valve is located on the feed line from Tk202 to Cooler 102 on the 3rd floor.

PIT-108

  • This pressure indicating transmitter is located on the overhead tower on the 3rd floor.

PV-108A

  • Run From atm to Reflux Drum 1st floor

PV-108B

  • Run From Reflux drum to atm 1st floor

TIT-109

  • This temperature indicating transmitter is located on the overhead tower on the 3rd floor.

HV-127

  • This hand valve runs from E-101 to the sump of tower-100 on the 2nd floor.

FIT-110

  • This flow indicating transmitter is located on the P-101 A/B to top Reflux to tower line on the 2nd floor.

FV-110

  • This flow valve is located on the P-101 A/B to top Reflux to tower line on the 2nd floor.

DPIT-113

  • This differential pressure indicating transmitter measures the pressure difference from tray 1 to 8 on the 2nd floor.

TIT-123

  • This temperature indicating transmitter measures the temperature of the 8th tray on the 3rd floor.

TIT-124

  • This temperature indicating transmitter measures the sump tower temperature on the 2nd floor.

LG-114

  • This is a level gauge for the bottoms on the 1st floor.

LIT-115

  • This is a level indicator for the bottoms of T-100 on the 1st floor.

LG-134

  • Reflux Drum level gauge ground floor

LIT-135

  • Reflux Drum Level Transmitter ground floor

TIT-136

  • Reflux Drum Temp ground floor

PI-101A/B

  • The Reflux pumps ground north of t-100

AIT-138

  • Reflux to tank line North ground analyzer

FIT-139

  • Reflux to tank line North ground of t-100 discharge line

LV-140

  • Reflux to tank line North ground of t-100 discharge

PI-132

  • Reflux drum temp gauge ground floor

LG-142

  • Seal Liquid level gauge low 20% high 80%

LALL-143

  • Seal liquid high alarm 80%

LAHH-141

  • Seal liquid low alarm 20%

PI-147

  • Reflux to C-100 upstream of compressor

PI-102A/B

  • Seal liquid pumps north side of E-103

TIT-146

  • Seal liquid Cooler E103 (downstream) to C-100

FIT-145

  • Seal liquid Cooler E103 (downstream) to C-100

FV-145

  • Seal liquid Cooler E103 (downstream) to C-100