Podcast
Questions and Answers
What is included in the form of Informational Notes according to NEC?
What is included in the form of Informational Notes according to NEC?
Explanatory material, such as references to other standards, references to related sections of the NEC, or information related to a Code rule.
Compliance with the provisions of the NEC will result in _____
Compliance with the provisions of the NEC will result in _____
an electrical system essentially free from hazard
The NEC applies to the installation of _____
The NEC applies to the installation of _____
What does the NEC not apply to?
What does the NEC not apply to?
Signup and view all the answers
The authority having jurisdiction shall not be allowed to enforce any requirements of Chapter 7 (Special Conditions) or Chapter 8 (Communications Systems).
The authority having jurisdiction shall not be allowed to enforce any requirements of Chapter 7 (Special Conditions) or Chapter 8 (Communications Systems).
Signup and view all the answers
The NEC does not cover electrical installations in ships, watercraft, railway rolling stock, aircraft, or automotive vehicles.
The NEC does not cover electrical installations in ships, watercraft, railway rolling stock, aircraft, or automotive vehicles.
Signup and view all the answers
By special permission, the authority having jurisdiction may waive specific requirements in this Code.
By special permission, the authority having jurisdiction may waive specific requirements in this Code.
Signup and view all the answers
Installations of communications equipment that are under the exclusive control of communications utilities are covered by the NEC.
Installations of communications equipment that are under the exclusive control of communications utilities are covered by the NEC.
Signup and view all the answers
Who has the responsibility for deciding on the approval of equipment and materials?
Who has the responsibility for deciding on the approval of equipment and materials?
Signup and view all the answers
Installations shall comply with the material located in the NEC Annexes because they are part of the requirements of the Code.
Installations shall comply with the material located in the NEC Annexes because they are part of the requirements of the Code.
Signup and view all the answers
In the NEC, the word(s) '_____' indicate a mandatory requirement.
In the NEC, the word(s) '_____' indicate a mandatory requirement.
Signup and view all the answers
The NEC is _____
The NEC is _____
Signup and view all the answers
The Code contains provisions considered necessary for safety, which will not necessarily result in _____
The Code contains provisions considered necessary for safety, which will not necessarily result in _____
Signup and view all the answers
Nonmandatory Informative Annexes contained in the back of the Code book _____
Nonmandatory Informative Annexes contained in the back of the Code book _____
Signup and view all the answers
Electric utilities may include entities that install, operate, and maintain _____
Electric utilities may include entities that install, operate, and maintain _____
Signup and view all the answers
Compliance with either the SI or the inch pound unit of measurement system shall be permitted.
Compliance with either the SI or the inch pound unit of measurement system shall be permitted.
Signup and view all the answers
Utilities may include entities that are designated or recognized by governmental law or regulation by public service/utility commissions.
Utilities may include entities that are designated or recognized by governmental law or regulation by public service/utility commissions.
Signup and view all the answers
Factory installed _____ wiring of listed equipment need not be inspected at the time of installation of the equipment.
Factory installed _____ wiring of listed equipment need not be inspected at the time of installation of the equipment.
Signup and view all the answers
This Code covers the installation of _____ for public and private premises, including buildings, structures, mobile homes, recreational vehicles, and floating buildings.
This Code covers the installation of _____ for public and private premises, including buildings, structures, mobile homes, recreational vehicles, and floating buildings.
Signup and view all the answers
Utilities may be subject to compliance with codes and standards covering their regulated activities.
Utilities may be subject to compliance with codes and standards covering their regulated activities.
Signup and view all the answers
The Code covers underground mine installations and self propelled mobile surface mining machinery and its attendant electrical trailing cable.
The Code covers underground mine installations and self propelled mobile surface mining machinery and its attendant electrical trailing cable.
Signup and view all the answers
Chapters 5, 6, and 7 apply to special occupancies, special equipment, or other special conditions.
Chapters 5, 6, and 7 apply to special occupancies, special equipment, or other special conditions.
Signup and view all the answers
Which systems shall be installed and removed in accordance with the NEC requirements?
Which systems shall be installed and removed in accordance with the NEC requirements?
Signup and view all the answers
The authority having jurisdiction has the responsibility for _____
The authority having jurisdiction has the responsibility for _____
Signup and view all the answers
The Code isn't intended as a design specification standard or instruction manual for untrained persons.
The Code isn't intended as a design specification standard or instruction manual for untrained persons.
Signup and view all the answers
If the NEC requires new products that are not yet available, who may permit the use of the products that comply with the most recent previous edition of the Code?
If the NEC requires new products that are not yet available, who may permit the use of the products that comply with the most recent previous edition of the Code?
Signup and view all the answers
Communications wiring within a building shall not be required to comply with the installation requirements of Chapters 1 through 7.
Communications wiring within a building shall not be required to comply with the installation requirements of Chapters 1 through 7.
Signup and view all the answers
Chapters 1 through 4 of the NEC apply generally to all electrical installations.
Chapters 1 through 4 of the NEC apply generally to all electrical installations.
Signup and view all the answers
Hazards often occur because of _____
Hazards often occur because of _____
Signup and view all the answers
When the Code uses '_____,' it means the identified actions are allowed but not required.
When the Code uses '_____,' it means the identified actions are allowed but not required.
Signup and view all the answers
Study Notes
Explanatory Notes and Compliance
- Informational Notes provide explanatory material, references to other standards, and information related to Code rules in NEC.
- Compliance with NEC provisions leads to an electrical system that is essentially hazard-free.
Scope of the NEC
- NEC applies to the installation of electrical conductors and equipment, including outside conductors and optical fiber cables within or on public and private buildings.
- Electric utility-owned wiring and equipment such as service drops or service laterals are excluded from NEC coverage.
- NEC does not cover installations in ships, aircraft, railway rolling stock, or automotive vehicles.
Authority and Regulations
- The authority having jurisdiction (AHJ) decides on the approval of equipment and materials and may waive specific Code requirements for safety assurance.
- Installations under exclusive control of communications utilities located outdoors are not covered by the NEC.
- Utilities may include entities recognized by law or regulation, encompassing communication and electric supply systems.
Code Application and Interpretations
- The NEC is formulated for the practical safeguarding of persons and property and does not necessarily ensure efficient use or convenience.
- Nonmandatory Informative Annexes in the NEC are for information only and are not enforceable requirements.
- Chapters 5, 6, and 7 of the NEC apply to special conditions and can modify requirements in earlier chapters.
Specific Installations and Measurements
- Compliance with either SI or inch-pound measurement systems is permissible.
- Factory-installed internal wiring of listed equipment does not require inspection unless alterations or damage are detected.
- The Code does not cover underground mine installations and subterranean machinery electrical cables.
Interpretations and Responsibilities
- AHJ is responsible for interpreting rules, approving equipment, and permitting alternate methods while ensuring safety.
- The Code aims not to serve as a design manual for untrained individuals, emphasizing safety standards in electrical installations.
Hazards and Risks
- Hazards may arise from overloading wiring systems or initial installations failing to account for future electricity usage increases.
- The term "shall be permitted" indicates actions that are allowed but not mandatory under the Code.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
Test your knowledge of the National Electrical Code (NEC) with these flashcards covering key definitions and concepts. Each card focuses on important regulations and compliance standards that ensure electrical safety. Perfect for students and professionals in electrical engineering.