What is the primary function of the mixer (M-814) installed inside the C14 Product Tank (TK-814)?
What is the primary function of the mixer (M-814) installed inside the C14 Product Tank (TK-814)?
The primary function of the mixer is to prevent settling/layering of sludge and maintain a homogeneous blend of different hydrocarbon densities inside the tank.
Describe the routing of C14 product from TK-814 with the P-814 pump.
Describe the routing of C14 product from TK-814 with the P-814 pump.
P-814 routes C14 product from TK-814 to either the C14 Loading Rack or the Heavy Rerun Header.
Explain why TK-814 is maintained under a nitrogen blanket.
Explain why TK-814 is maintained under a nitrogen blanket.
TK-814 is maintained under a nitrogen blanket to prevent moisture or oxygen contamination.
Considering the type of pump used, what kind of flowrate can we expect from P-814?
Considering the type of pump used, what kind of flowrate can we expect from P-814?
How does product enter and exit TK-814?
How does product enter and exit TK-814?
Flashcards
TK-814 (C14 Product Tank)
TK-814 (C14 Product Tank)
Receives C14 product from T-450 overhead and exchanges C14 with TK-1814's inlet in Unit 1798. It can also send/receive C14 to/from TK-1814's outlet. Maintained under a nitrogen blanket.
M-814 (C14 Product Tank Mixer)
M-814 (C14 Product Tank Mixer)
Prevents settling and maintains a consistent mixture of hydrocarbons within TK-814.
P-814 (C14 Loading Pump)
P-814 (C14 Loading Pump)
Routes C14 product from TK-814 to the C14 Loading Rack or Heavy Rerun Header.
TK-814 Structure
TK-814 Structure
Signup and view all the flashcards
P-814 Type
P-814 Type
Signup and view all the flashcards
Study Notes
- TK-814 receives C14 product from the overhead of T-450.
- TK-814 receives and sends C14 product from and to the inlet of TK-1814 in Unit 1798.
- C14 product can be sent and received from and to the outlet line of TK-1814 in Unit 1798 via the outlet of TK-814.
- P-814 (C14 Loading Pump) routes the C14 product to the C14 Loading Rack or the Heavy Rerun Header.
- TK-814 has an internal mixer M-814 (C14 Product Tank Mixer).
- The tank is maintained under a nitrogen blanket from D-801 to prevent moisture or oxygen contamination.
TK-814 (C14 Product Tank)
- TK-814 is 55’ in diameter and 48’ long and is equipped with a cone roof and a mixer.
- TK-814 is installed to store C14 product.
- Product to TK-814 enters and exits the bottom of the tank.
M-814 (C14 Product Tank Mixer)
- M-814 is installed internally in TK-814 to avoid settling/layering of sludge and to maintain a homogeneous blend of different hydrocarbon densities.
- M-814 is driven by a 7.5HP 12885 GPM induction electric motor.
P-814 (C14 Loading Pump)
- P-814 is a single-stage centrifugal pump.
- It is driven by a 30 HP 3535 RPM horizontally-mounted, induction electric motor.
- The purpose is to route C14 product from TK-814 to C14 Loading Rack.