TK-814 C14 Product Tank

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson
Download our mobile app to listen on the go
Get App

Questions and Answers

What is the primary function of the mixer (M-814) installed inside the C14 Product Tank (TK-814)?

The primary function of the mixer is to prevent settling/layering of sludge and maintain a homogeneous blend of different hydrocarbon densities inside the tank.

Describe the routing of C14 product from TK-814 with the P-814 pump.

P-814 routes C14 product from TK-814 to either the C14 Loading Rack or the Heavy Rerun Header.

Explain why TK-814 is maintained under a nitrogen blanket.

TK-814 is maintained under a nitrogen blanket to prevent moisture or oxygen contamination.

Considering the type of pump used, what kind of flowrate can we expect from P-814?

<p>Since it's a centrifugal pump, expect relatively high flowrates, but lower pressure. Based on the text, the motor for M-814 is rated for <code>12885 GPM</code>. However, the pump, P-814, is mentioned later in the text, and does not have a flowrate included. If the student mentions the motor, M-814, that is ok, otherwise, there is not enough information to answer this question.</p> Signup and view all the answers

How does product enter and exit TK-814?

<p>Product enters and exits TK-814 at the bottom of the tank.</p> Signup and view all the answers

Flashcards

TK-814 (C14 Product Tank)

Receives C14 product from T-450 overhead and exchanges C14 with TK-1814's inlet in Unit 1798. It can also send/receive C14 to/from TK-1814's outlet. Maintained under a nitrogen blanket.

M-814 (C14 Product Tank Mixer)

Prevents settling and maintains a consistent mixture of hydrocarbons within TK-814.

P-814 (C14 Loading Pump)

Routes C14 product from TK-814 to the C14 Loading Rack or Heavy Rerun Header.

TK-814 Structure

A tank (55’D x 48’L) with a cone roof and mixer, used for storing C14 product.

Signup and view all the flashcards

P-814 Type

A single-stage centrifugal pump driven by a 30 HP electric motor.

Signup and view all the flashcards

Study Notes

  • TK-814 receives C14 product from the overhead of T-450.
  • TK-814 receives and sends C14 product from and to the inlet of TK-1814 in Unit 1798.
  • C14 product can be sent and received from and to the outlet line of TK-1814 in Unit 1798 via the outlet of TK-814.
  • P-814 (C14 Loading Pump) routes the C14 product to the C14 Loading Rack or the Heavy Rerun Header.
  • TK-814 has an internal mixer M-814 (C14 Product Tank Mixer).
  • The tank is maintained under a nitrogen blanket from D-801 to prevent moisture or oxygen contamination.

TK-814 (C14 Product Tank)

  • TK-814 is 55’ in diameter and 48’ long and is equipped with a cone roof and a mixer.
  • TK-814 is installed to store C14 product.
  • Product to TK-814 enters and exits the bottom of the tank.

M-814 (C14 Product Tank Mixer)

  • M-814 is installed internally in TK-814 to avoid settling/layering of sludge and to maintain a homogeneous blend of different hydrocarbon densities.
  • M-814 is driven by a 7.5HP 12885 GPM induction electric motor.

P-814 (C14 Loading Pump)

  • P-814 is a single-stage centrifugal pump.
  • It is driven by a 30 HP 3535 RPM horizontally-mounted, induction electric motor.
  • The purpose is to route C14 product from TK-814 to C14 Loading Rack.